SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:hb-8468"
 

Sökning: onr:"swepub:oai:DiVA.org:hb-8468" > Quality of Chest Co...

Quality of Chest Compressions Differs over Time between Advanced and Basic Life Support

Lindblad, Pär (författare)
Åström Victorén, Annika (författare)
Axelsson, Christer (författare)
Högskolan i Borås,Akademin för vård, arbetsliv och välfärd,PreHospen
visa fler...
Bjarne Madsen, Härdig (författare)
visa färre...
 (creator_code:org_t)
Scientific Research Publishing, Inc. 2015
2015
Engelska.
Ingår i: International Journal of Clinical Medicine. - : Scientific Research Publishing, Inc.. - 2158-284X .- 2158-2882. ; 6:12, s. 944-953
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: According to guideline recommendations, chest compressions (CC) during cardiopulmonary resuscitation (CPR) should be performed at a rate of 100 - 120 per minute, with a CC fraction (CCF) of ≥80%. The aim of this work is to explore whether CC quality differs between advanced life support (ALS) and basic life support (BLS) performed by two rescuers. Method: Cardiopulmonary resuscitation was performed by two ambulance personnel in ten ALS and ten BLS manikin scenarios. Data from these scenarios were then compared with data on ten ALS cases from the clinical setting, all with non-shockable rhythms. Data from the first two 5-minute periods of CC were evaluated from impedance data (LIFEPAK 12 defibrillator monitors) using a modified Laerdal Skillmaster manikin. Quality parameters compared were: number of CC pauses (CCPs), total time of CC (%), number of CC given and CC rate/min. Results: During the first 5 minutes, the BLS manikin scenarios had the highest number of CCPs, 15 (14 - 16), compared with the ALS manikin scenario, 14 (13 - 15), and the clinical ALS cases, 12 (10 - 15). The BLS scenario also had the highest CCFs, 81% (77% - 85%), and number of CC, 450 (435 - 495), compared with the ALS manikin scenario, 75% (64% - 81%) and 400 (365 - 444) respectively, and the clinical ALS cases, 63% (50% - 74%) and 408 (306 - 489). The median rate of CC/min in the BLS scenario was 115 (110 - 120) compared with the ALS manikin scenario, 110 (106 - 115), and the clinical ALS cases, 130 (118 - 146). During the second 5-minute period, the BLS scenario had the highest number of CCPs, 16 (15 - 17), compared with 15 (14 - 16) for the ALS manikin scenario and 11 (11 - 12) for the clinical ALS cases. The CCF in the BLS setting was 79% (75% - 83%), and the number of CC 455 (430 - 480), compared with the ALS manikin scenario, 79% (74% - 84%) and 435 (395 - 480) respectively, and the clinical ALS cases, 71% (57% - 77%) and 388 (321 - 469) respectively. The median CC rate was 118 (113 - 124) for BLS, 111 (105 - 120) for ALS manikins and 123 (103 - 128) CC/min for clinical ALS cases. Conclusion: None of the groups being studied could deliver CC at a rate of 100 - 120 CC/min or a CCF of ≥80% over the whole 10-minute period in any of the resuscitation scenarios analyzed. However, BLS had the best compliance with CC quality recommendations according to the 2010 guidelines.

Nyckelord

Cardiac Arrest
External Chest Compression
Cardiac Resuscitation
Advanced Life Support
Basic Life Support
Människan i vården
Människan i vården

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy