Electroanatomic Mapping of Focal Atrial Tachycardia : Reproducibility ofActivation Time Measurement and Focus Localization

Liuba, Ioan (författare)
Östergötlands Läns Landsting,Linköpings universitet,Kardiologi,Hälsouniversitetet,Kardiologiska kliniken
Jönsson, Anders (författare)
Östergötlands Läns Landsting,Linköpings universitet,Kardiologi,Hälsouniversitetet,Kardiologiska kliniken
Walfridsson, Håkan (författare)
Östergötlands Läns Landsting,Linköpings universitet,Kardiologi,Hälsouniversitetet,Kardiologiska kliniken
 (creator_code:org_t)
2010
2010
Engelska.
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • Background: Different algorithms of estimating local activation time (LAT) can be usedduring the mapping of focal atrial tachycardia (FAT). Objective: The impact of these algorithms on the reproducibility of LAT measurementand the location of the focus. Methods: Fifteen patients (48 ± 17 yrs) with FAT were studied. Three independentobservers reviewed 1438 bipolar electrograms and successively assigned the LAT on thepeak amplitude (Bi-peak), the steepest downslope (Bi-dslope), and the onset (Bi-on) ofthe electrograms. The reproducibility of LAT measurement was estimated. Results: The mean interobserver absolute differences in LAT for the three algorithmswere 1.47 ± 2.75 ms (Bi-peak) vs. 2.15 ± 3.89 ms (Bi-dslope) vs. 2.87 ± 3.47 (Bi-on) (p <0.0001). The corresponding intraobserver differences were 2.29 ± 3.74 ms (Bi-peak) vs2.47 ± 4.17 ms (Bi-dslope) vs 3.16 ± 4.49 ms (Bi-on) (p < 0.0001). The interobserverdifferences in the location of the focus were 3.57 ± 3.81 mm (Bi-peak) vs 5.47 ± 4.98mm (Bi-dslope) vs 6.57 ± 6.94 mm (Bi-on) (p = 0.03), with differences of up to 13 mm(Bi-peak), 16 mm (Bi-dslope), and 25 mm (Bi-on). However, regardless of the method ofLAT determination, the foci computed by the three observers clustered within regions oflow-amplitude fractionated electrograms. Conclusions: Significant observer variability exists among the three algorithms, whichtend to compute different LAT and foci with different locations. However, the foci aresituated in regions of low voltage fractionated electrograms.

Nyckelord

Ectopic atrial tachycardia; catheter ablation; atrial electrogram
MEDICINE
MEDICIN

Publikations- och innehållstyp

vet (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy