SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:umu-54328"
 

Sökning: onr:"swepub:oai:DiVA.org:umu-54328" > Oxidation of pharma...

Oxidation of pharmaceuticals by chlorine dioxide in biologically treated wastewater

Hey, Gerly (författare)
Lund University,Lunds universitet,Avdelningen för kemiteknik,Institutionen för processteknik och tillämpad biovetenskap,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Chemical Engineering,Department of Process and Life Science Engineering,Departments at LTH,Faculty of Engineering, LTH
Grabic, Roman (författare)
Umeå universitet,Kemiska institutionen
Ledin, Anna (författare)
Lund University,Lunds universitet,Avdelningen för kemiteknik,Institutionen för processteknik och tillämpad biovetenskap,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Chemical Engineering,Department of Process and Life Science Engineering,Departments at LTH,Faculty of Engineering, LTH
visa fler...
la Cour Jansen, Jes (författare)
Lund University,Lunds universitet,Avdelningen för kemiteknik,Institutionen för processteknik och tillämpad biovetenskap,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Chemical Engineering,Department of Process and Life Science Engineering,Departments at LTH,Faculty of Engineering, LTH
Andersen, H. R. (författare)
visa färre...
 (creator_code:org_t)
Elsevier, 2012
2012
Engelska.
Ingår i: Chemical Engineering Journal. - : Elsevier. - 1385-8947 .- 1873-3212. ; 185, s. 236-242
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Biologically treated wastewater spiked with a mixture of 56 active pharmaceutical ingredients (APIs) was treated with 0-20 mg/L chlorine dioxide (ClO2) solution in laboratory-scale experiments. Wastewater effluents were collected from two wastewater treatment plants in Sweden, one with extended nitrogen removal (low COD) and one without (high COD). About one third of the tested APIs resisted degradation even at the highest ClO2 dose (20 mg/L), while others were reduced by more than 90% at the lowest ClO2 level (0.5 mg/L). In the low COD effluent, more than half of the APIs were oxidized at 5 mg/L ClO2, while in high COD effluent a significant increase in API oxidation was observed after treatment with 8 mg/L ClO2. This study illustrates the successful degradation of several APIs during treatment of wastewater effluents with chlorine dioxide.

Ämnesord

NATURVETENSKAP  -- Kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Kemiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Chemical Engineering (hsv//eng)

Nyckelord

Pharmaceuticals
Chlorine dioxide
Wastewater effluent
Pharmaceuticals
Chlorine dioxide
Wastewater effluent

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Hey, Gerly
Grabic, Roman
Ledin, Anna
la Cour Jansen, ...
Andersen, H. R.
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Kemi
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Kemiteknik
Artiklar i publikationen
Chemical Enginee ...
Av lärosätet
Umeå universitet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy