CONVERSION FACTORS FOR ESTIMATION OF EFFECTIVE DOSE IN PAEDIATRIC CHEST TOMOSYNTHESIS.
-
- Vult von Steyern, Kristina (författare)
- Lund University,Lunds universitet,Diagnostisk radiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Diagnostic Radiology, (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
-
- Björkman-Burtscher, Isabella (författare)
- Lund University,Lunds universitet,Diagnostisk radiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Diagnostic Radiology, (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
-
- Geijer, Mats (författare)
- Lund University,Lunds universitet,Diagnostisk radiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Diagnostic Radiology, (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
-
visa fler...
-
- Weber, Lars (författare)
- Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
-
visa färre...
-
(creator_code:org_t)
- 2013-06-10
- 2013
- Engelska.
-
Ingår i: Radiation Protection Dosimetry. - : Oxford University Press (OUP). - 1742-3406 .- 0144-8420. ; 157:2, s. 206-213
- Relaterad länk:
-
http://www.ncbi.nlm....
-
visa fler...
-
http://dx.doi.org/10...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- For chest tomosynthesis in adults, a conversion factor of 0.26 mSv/Gy cm(2) has been reported for calculating the effective dose from the registered dose-area-product. The aim of this study was to determine conversion factors for chest tomosynthesis in children. Using the Monte Carlo-based computer software PCXMC 2.0, simulations were performed on modified phantoms for males and females aged 8-19 y, in the posteroanterior and anteroposterior projection, with energies 80-140 kV and copper filtration 0.1-0.3 mm. Resulting conversion factors ranged between 0.23 and 1.09 mSv/Gy cm(2), decreased with patient age, were significantly higher in the anteroposterior projection and increased with increased energy or copper filtration. To avoid an underestimation of effective dose in children, it is recommended to use age-dependent conversion factors. As a simplified approach, three conversion factors might be used for posteroanterior chest tomosynthesis and radiography in children, namely 0.6 (8-10 y), 0.4 (11-14 y) and 0.3 mSv/Gy cm(2) (15-19 y).