SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:lup.lub.lu.se:c5409c7e-61a0-44e0-99f8-0e13bf2edc43"
 

Sökning: onr:"swepub:oai:lup.lub.lu.se:c5409c7e-61a0-44e0-99f8-0e13bf2edc43" > FLOPSYNC-2: efficie...

FLOPSYNC-2: efficient monotonic clock synchronisation

Terraneo, Federico (författare)
Rinaldi, Luigi (författare)
Maggio, Martina (författare)
Lund University,Lunds universitet,Institutionen för reglerteknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Automatic Control,Departments at LTH,Faculty of Engineering, LTH
visa fler...
Papadopoulos, Alessandro Vittorio (författare)
Lund University,Lunds universitet,Institutionen för reglerteknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Automatic Control,Departments at LTH,Faculty of Engineering, LTH
Leva, Alberto (författare)
visa färre...
 (creator_code:org_t)
2014
2014
Engelska.
Ingår i: [Host publication title missing]. - 1052-8725. - 9781479972883 ; , s. 11-20
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • Time synchronisation is crucial for distributed systems, and particularly for Wireless Sensor Networks (WSNs), where each node is executing concurrent operations to achieve a real-time objective. However, synchronisation is quite difficult to achieve in WSNs, due to the unpredictable deployment conditions and to physical effects like thermal stress, that cause drifts in the local node clocks. As a result, state-of-the-art synchronisation schemes do not guarantee monotonicity of the nodes clock, or are relying on external hardware assistance. In this paper we present FLOPSYNC-2, a scheme to synchronise the clocks of multiple nodes in a WSN, requiring no additional hardware, and based on the application of control-theoretical principles. The scheme guarantees low overhead, low power consumption and synchronisation with clock monotonicity. We propose an implementation of FLOPSYNC-2 on top of the microcontroller operating system Miosix, and prove the validity of our claims with several-days-long experiments on an eight-hop network. The experimental results show that the average clock difference among nodes is limited to a hundred of ns, with a sub-μs standard deviation. By introducing a suitable power model, we also prove that synchronisation is achieved with a sub-μA consumption overhead.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Reglerteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Control Engineering (hsv//eng)

Nyckelord

Synchronisation
Wireless Sensor Network

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy