Determining Short Chain Fatty Acids in Sewage Sludge Hydrolysate: A Comparison of Three Analytical Methods and Investigation of Sample Storage Effects

Ibrahim, Victor (författare)
Lund University,Lunds universitet,Bioteknik,Centrum för tillämpade biovetenskaper,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Biotechnology,Center for Applied Life Sciences,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Hey, Tobias (författare)
Lund University,Lunds universitet,Avdelningen för kemiteknik,Institutionen för processteknik och tillämpad biovetenskap,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Chemical Engineering,Department of Process and Life Science Engineering,Departments at LTH,Faculty of Engineering, LTH
Jönsson, Karin (författare)
Lund University,Lunds universitet,Avdelningen för kemiteknik,Institutionen för processteknik och tillämpad biovetenskap,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Chemical Engineering,Department of Process and Life Science Engineering,Departments at LTH,Faculty of Engineering, LTH
 (creator_code:org_t)
2014
2014
Engelska.
Ingår i: Journal of Environmental Sciences(China). - 1001-0742. ; 26:4, s. 926-933
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In anaerobic digestion (AD), the production of short-chain fatty acids (SCFAs) can be beneficial or harmful to the overall process, depending on the concentration of accumulated acids. Therefore, the accurate determination of the SCFA concentration in both fresh and stored sludge hydrolysates is important. To select a suitable method for monitoring SCFAs during the AD of sewage sludge, the accuracy of three available analytical methods, including 5 pH point acid titration (TITRA5), gas chromatography (GC), and spectrophotometry, were compared in the present study. The results revealed that TITRA5 and GC displayed better agreement in the achieved measurements and higher precision and accuracy than the spectrophotometric assay, as supported by the application of different statistical models. TITRA5 excelled in titrating unfiltered hydrolysate while simultaneously measuring the alkalinity, whereas the GC method provided detailed information on the contribution of different fatty acids to the total acidity. In contrast, the spectrophotometric assay suffered from many forms of interference, depending on the sample’s matrix. SCFA production followed the pattern of enzymatic reactions and fitted the Michaelis-Menten model. In addition to promoting TITRA5 as an accurate and robust analytical tool for routine SCFA analyses, this comparative study also demonstrated the possibility of storing hydrolysate samples at different temperatures and durations without altering the SCFA measurements.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Kemiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Chemical Engineering (hsv//eng)

Nyckelord

Five pH point titration
gas chromatography
spectrophotometry
short-chain fatty acids
sludge hydrolysis
sample storage

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Ibrahim, Victor
Hey, Tobias
Jönsson, Karin
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Kemiteknik
Artiklar i publikationen
Journal of Envir ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy