SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Wennerberg Ann 1955 ) "

Sökning: WFRF:(Wennerberg Ann 1955 )

  • Resultat 91-100 av 137
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
91.
  •  
92.
  • Mustafa, Kamal, et al. (författare)
  • The influence of surface topography of ceramic abutments on the attachment and proliferation of human oral fibroblasts.
  • 2005
  • Ingår i: Biomaterials. - : Elsevier BV. - 0142-9612. ; 26:4, s. 373-81
  • Tidskriftsartikel (refereegranskat)abstract
    • As different implant abutments are introduced to obtain a sufficient soft tissue barrier, the aim of this study was to determine the effect of three different surface modifications of densely sintered high-purity aluminium oxide on morphology, attachment and proliferation of human gingival fibroblasts. Fibroblasts were cultured on pressed aluminium oxide, milled, and then sintered to full density (1), on pressed, densely sintered (2), and on pressed, densely sintered and then polished surfaces (3). The different surfaces were analyzed using a confocal laser scanner, an atomic force microscope and a scanning electron microscope. The cell profile areas were measured using a semiautomatic interactive image analyzer and the figures were expressed as percent of attachment. The polished specimens had the smoothest surfaces and the roughest were the milled surfaces in terms of height deviation. No difference was found in the spacing between the peaks on the polished surfaces compared to the milled surfaces. Fibroblasts on the milled ceramic appeared to follow the direction of the fine irregularities on the surface. The analyses showed the polished surfaces had significantly higher percentages of initial cell attachment than the other surfaces (P < 0.05). After 3 days of cell culture, significantly more cells were attached to the milled and sintered surfaces than to the polished one, possibly indicating higher proliferation capacity on those types of surfaces.
  •  
93.
  • Nilsson, Andree, et al. (författare)
  • Infraposition of anterior maxillary implant-supported single-tooth restorations in adolescent and adult patients-A prospective follow-up study up to 6 years
  • 2019
  • Ingår i: Clinical Implant Dentistry and Related Research. - : John Wiley & Sons. - 1523-0899 .- 1708-8208. ; 21:5, s. 953-959
  • Tidskriftsartikel (refereegranskat)abstract
    • Background In the maxillary incisor area infraposition of implant restorations can be an esthetic problem. Purpose The aim was to analyze the prevalence of infraposition of single-tooth implant restorations in the anterior maxilla in adolescent and adult patients. Material and Methods The study comprised of 31 patients, 18 women and 13 men, with 39 restorations and with a mean and median age of 23.8 and 18.8 years, range 17.8 to 52.8 years, at the time of implant crown connection. The mean and median time in function for the restorations was 4.5 and 4.3 years respectively with a range of 3.3 to 6.6 years. Results Twenty restorations 51%, showed no signs of infraposition. A slight infraposition (<0.5 mm) was seen in 36% of the restorations. Only in one patient, the observed infraposition of the implant crown was more than 1 mm. We found no significant difference of the observed level of vertical infraposition, Score A (0 mm) and Score B (<0.5 mm), in subjects where the restoration was placed before the age of 20 years compared to the older patients. There were no significant differences in changes of the vertical infraposition when comparing different parameters such as age, gender, jaw relation (Angle-classes I-III), overbite/overjet, occlusal contact on the implant crown, bone augmentation before or at implant installation or if orthodontic treatment of the neighboring teeth had been made before or after the implant installation. Conclusions In the present study, there was a significant yet low correlation between the observed vertical infraposition of the single-tooth implant restoration and the subject's evaluation of the esthetics of the restoration (VAS). Fifty-one percent of the implant-supported crowns, showed no signs of vertical infraposition. A slight infraposition (< 0.5 mm) was however seen in 36% of the restorations. Only one crown showed a vertical infraposition of more than 1 mm.
  •  
94.
  • Olander, Julia, 1984, et al. (författare)
  • Implant-Supported Single Crowns with Titanium or Zirconia Abutments: A Retrospective Up-to-5-year Follow-up Study.
  • 2022
  • Ingår i: The International journal of prosthodontics. - : Quintessence Publishing. - 1942-4426 .- 0893-2174. ; 35:4, s. 387-395
  • Tidskriftsartikel (refereegranskat)abstract
    • To compare the clinical outcomes of single implants with titanium (Ti) or zirconia (Zr) abutments after up to 5 years in function.This study was a retrospective analysis on single implants with screw-retained abutments (Zr or Ti) covered with porcelain veneer placed between 2011 and 2013 at one referral specialist clinic. Clinical data from patient records were collected from 132 patients and 174 implants. Technical complications such as fractures, chipping, and abutment screw loosening were registered. Radiographs were analyzed comparing both annual bone loss and accumulated bone loss at 5 years. In 57 patients with 85 implants, the values of accumulated bone loss at 5 years were compared to baseline.Technical complications occurred in 16 (9%) of the implants, most often during the first year. The following complications were found: fracture of the abutment (n = 1); loosening of the abutment screws (n = 5); and chipping of the porcelain veneer (n = 11). Ti abutments had more complications than Zr abutments (79%). Of all the implants, 45% had an annual bone loss ranging between 0.05 and 2.15 mm, and 59% had an accumulated bone loss at 5 years ranging between 0.05 and 4.25 mm. Zr abutments had a statistically significantly higher amount of yearly and accumulated bone loss at 5 years.Abutment material affected marginal bone loss. The Zr group displayed statistically more bone loss both yearly and after 5 years compared to the Ti group. Technical complications were not affected by abutment material but were affected by age of the patient.
  •  
95.
  • Olander, Julia, 1984, et al. (författare)
  • Inflammatory Gene Profile and Particle Presence in Peri-Implant Mucosa: a Pilot Study on 9 Patients
  • 2023
  • Ingår i: Jomr-Journal of Oral & Maxillofacial Research. - 2029-283X. ; 14:3
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: The purpose of this pilot study is to compare gene expression in mucosa around dental implants with zirconia abutment to titanium and investigate presence of particles in mucosa samples and on implant heads. Material and Methods: Ten patients with a single implant supported prosthesis connected to zirconia or titanium abutments were invited at the five-year control. A clinical examination and a survey on experience of function and appearance were conducted. A mucosa biopsy taken in close vicinity to the implant were analysed by real-time polymerase chain reaction (qPCR) and presence of particles in a scanning electron microscope/energy-dispersive X-ray spectroscope (SEM/EDX). Cytological smear samples were collected and analysed through inductively coupled plasma mass spectrometry (ICP-MS) to investigate presence of particles on implant heads. Results: In total, 9 patients participated in the study, five with titanium abutments and four with zirconia abutments. All patients were satisfied with function and aesthetics. Titanium and iron particles were detected in mucosa biopsies. The ICP -MS analysis demonstrated presence of zirconia and titanium. Several proinflammatory genes were upregulated in the zirconia abutment group. Conclusions: Around zirconia abutments a slight increase in proinflammatory response and amount of wear particles was seen as compared to titanium. Wear particles of titanium were present in all soft tissue samples, however zirconia particles only in the samples from implants heads/mucosa with zirconia abutments.
  •  
96.
  • Olander, Julia, 1984, et al. (författare)
  • Wear particle release at the interface of dental implant components: Effects of different material combinations. An in vitro study
  • 2022
  • Ingår i: Dental Materials. - : Elsevier BV. - 0109-5641. ; 38:3, s. 508-516
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: Particle generation from implant components caused by frictional wear affect the surrounding peri-implant tissues. The objective of this study was to evaluate the effect of combining implant and abutment materials on wear and particle release in a dynamical loading setup. Methods: A customized dynamical loading machine was used to subject two implant materials (Titanium and Titanium- Zirconium alloy) paired with two different abutment materials (Titanium and Zirconia) to a cyclic loading set of 240.000 cycles (simulating 1 year of clinical use). The implant and abutment complex was immersed in corrosive liquid to collect particle debris and measure the release of corroded ions. Scanning electron microscopy was used to analyze signs of wear on the components after testing and evaluate the size and composition of particle debris. Results: Wear signs were evident in all material couplings. Particle debris was found on top, inside the implants, and on the abutment heads. The particle size ranged between 0.6 and 16.9 µm, with larger particles composed of Ti. Smaller-sized particles were found in the container liquid ranging from 0.253 to 1.7 µm compared to inside the implants ranging from 3.25 to 95.3 µm. Larger particles were found inside Tizr implants compared to Ti implants. Low levels of ions released due to corrosion were found when measuring content in surrounding liquid. Significance: Particle generation is evident when subjecting dental implant and abutment couplings in a dynamic loading setup. Internally connected implants hinder the release of larger particles to surrounding container liquid. © 2022 The Authors
  •  
97.
  • Peruzzi, Niccolò, et al. (författare)
  • Multimodal ex vivo methods reveal that Gd-rich corrosion byproducts remain at the implant site of biodegradable Mg-Gd screws
  • 2021
  • Ingår i: Acta Biomaterialia. - : Elsevier. - 1742-7061 .- 1878-7568. ; 136, s. 582-591
  • Tidskriftsartikel (refereegranskat)abstract
    • Extensive research is being conducted on magnesium (Mg) alloys for bone implant manufacturing, due to their biocompatibility, biodegradability and mechanical properties. Gadolinium (Gd) is among the most promising alloying elements for property control in Mg alloy implants; however, its toxicity is controversial. Investigating Gd behavior during implant corrosion is thus of utmost importance. In this study, we analyzed the degradation byproducts at the implant site of biodegradable Mg-5Gd and Mg-10Gd implants after 12 weeks healing time, using a combination of different imaging techniques: histology, energy-dispersive x-ray spectroscopy (EDX), x-ray microcomputed tomography (µCT) and neutron µCT. The main finding has been that, at the healing time in exam, the corrosion appears to have involved only the Mg component, which has been substituted by calcium and phosphorus, while the Gd remains localized at the implant site. This was observed in 2D by means of EDX maps and extended to 3D with a novel application of neutron tomography. X-ray fluorescence analysis of the main excretory organs also did not reveal any measurable accumulation of Gd, further reinforcing the conclusion that very limited or no removal at all of Gd-alloy happened during degradation.
  •  
98.
  • Qian, Jie, et al. (författare)
  • Reasons for Marginal Bone Loss around Oral Implants
  • 2012
  • Ingår i: Clinical Implant Dentistry and Related Research. - : Wiley. - 1523-0899 .- 1708-8208. ; 14:6, s. 792-807
  • Tidskriftsartikel (refereegranskat)abstract
    • Background The reasons for long-term marginal bone loss around oral implants are not well understood. Purpose The aim of this paper is to analyze presented evidence behind anticipated reasons for long-term marginal bone loss around oral implants. Materials and Methods A computerized research was conducted on PubMed in April 2011 with the following keywords: oral implants and marginal bone resorption/crestal bone loss/bone loss/bone resorption. This search resulted in a total of one thousand one hundred ninety-four papers of which seven hundred fifty-three were clinical contributions. Further search and filtering finally resulted in 21 experimental studies and one hundred sixteen clinical studies, which were reviewed. Results No evidence was found that primary infection caused marginal bone resorption. Clinical papers that have reported high levels of peri-implantitis were not supported by data given. Clinical evidence was presented that the so-called combined factors (implant hardware, clinical handling, and patient characteristics) may lead to marginal bone resorption. However, once tissue damage has been caused by combined factors, inflammation and/or infection may develop secondarily and then result in peri-implantitis that may need particular clinical treatment. Conclusions As marginal bone loss primarily depends on numerous background factors, it seems logical that, for example, the use of poorly constructed implants placed and handled by untrained clinicians may result in high numbers of patients with secondary problems in form of peri-implantitis; having said this, control of combined factors may likewise lead to very good clinical results where peri-implantitis would represent a very rare disease indeed even at follow-up times of 10 years or more.
  •  
99.
  • Reigstad, O., et al. (författare)
  • Improved bone ingrowth and fixation with a thin calcium phosphate coating intended for complete resorption
  • 2007
  • Ingår i: Journal of biomedical materials research. Part B, Applied biomaterials. - : Wiley. - 1552-4973 .- 1552-4981. ; 83B:1, s. 9-15
  • Tidskriftsartikel (refereegranskat)abstract
    • Bonit is claimed to be a resorbable electrochemically deposited calcium phosphate coating consisting mainly of brushite, which is a hydroxyapatite precursor. This study involved a comparison of Ti6Al4V screw-shaped implants with and without a 15 +/- 5 microm Bonit coating in rabbit tibia and femur, after 6 and 12 weeks of insertion. The biomechanical removal torque test showed significantly increased values for the coated implants after 12 weeks (p < 0.05) but not after 6 weeks of integration. Higher bone-implant contact was found for the coated implants in the tibia after 6 weeks and for both tibial and femoral screws after 12 weeks (p < 0.05). There was no difference in the inflammatory reaction around the implants, and possible grains of the coating could be detected after 6 weeks, but not after 12 weeks of follow-up. This unloaded short-term study has shown promising results for the easily applicable and resorbable coat (Bonit) compared to uncoated titanium-alloy implants.
  •  
100.
  • Reinedahl, David, et al. (författare)
  • Aseptic Ligatures Induce Marginal Peri-Implant Bone Loss-An 8-Week Trial in Rabbits
  • 2019
  • Ingår i: Journal of Clinical Medicine. - : MDPI. - 2077-0383. ; 8:8
  • Tidskriftsartikel (refereegranskat)abstract
    • The clinical value of ligature-induced experimental peri-implantitis studies has been questioned due to the artificial nature of the model. Despite repeated claims that ligatures of silk, cotton and other materials may not induce bone resorption by themselves; a recent review showed that the tissue reaction toward them has not been investigated. Hence, the current study aimed to explore the hard and soft tissue reactions toward commonly used ligature materials. A total of 60 dental implants were inserted into the femur ( = 20) and tibia ( = 40) of 10 rabbits. The femoral implants were ligated with sterile 3-0 braided silk in one leg and sterile cotton retraction chord in the other leg. The tibial implants were ligated with silk or left as non-ligated controls. All wounds were closed in layers. After a healing time of 8 weeks, femoral (silk versus cotton) and proximal tibial (silk versus non-ligated control) implants were investigated histologically. Distal tibial (silk versus non-ligated control) implants were investigated with real time polymerase chain reaction (qPCR). The distance from the implant-top to first bone contact point was longer for silk ligated implants compared to non-ligated controls ( = 0.007), but did not vary between cotton and silk. The ligatures triggered an immunological reaction with cell infiltrates in close contact with the ligature materials, adjacent soft tissue encapsulation and bone resorption. qPCR further demonstrated an upregulated immune response toward the silk ligatures compared to non-ligated controls. Silk and cotton ligatures provoke foreign body reactions of soft tissue encapsulation type and bone resorption around implants in the absence of plaque.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 91-100 av 137
Typ av publikation
tidskriftsartikel (117)
konferensbidrag (8)
forskningsöversikt (7)
bokkapitel (5)
Typ av innehåll
refereegranskat (131)
övrigt vetenskapligt/konstnärligt (6)
Författare/redaktör
Wennerberg, Ann, 195 ... (133)
Albrektsson, Tomas, ... (57)
Franke Stenport, Vic ... (14)
Arvidsson, Anna, 197 ... (13)
Galli, Silvia (11)
Chrcanovic, Bruno (11)
visa fler...
Johansson, Carina B. ... (11)
Meirelles, Luiz, 197 ... (11)
Sul, Young-Taeg, 196 ... (10)
Andersson, Martin, 1 ... (10)
Kjellin, Per, 1972 (8)
Tengvall, Pentti (7)
Kjellin, P (6)
Toia, Marco (6)
Jimbo, Ryo (5)
Jemt, Torsten, 1950 (5)
Jimbo, Ryo, 1979 (5)
Currie, Fredrik, 197 ... (5)
Göransson, Anna, 197 ... (5)
Lindhe, Jan, 1935 (4)
Albrektsson, Tomas (4)
Wennerberg, Ann (4)
Sennerby, Lars, 1960 (4)
Gretzer, Christina, ... (4)
Stocchero, Michele (4)
Hammarström Johansso ... (4)
Becktor, Jonas P (4)
Sawase, Takashi (4)
Fröjd, Victoria, 198 ... (4)
Berglundh, Tord, 195 ... (3)
Larsson, Christel (3)
Thomsen, Peter, 1953 (3)
Reinedahl, David (3)
Trindade, Ricardo (3)
Jacobsson, Magnus (3)
Östman, Pär-Olov, 19 ... (3)
Örtengren, Ulf, 1959 (3)
Milleding, Percy, 19 ... (3)
Willumeit-Romer, R. (3)
Peruzzi, Niccolò (3)
Prgomet, Zdenka (3)
Kruger, D. (3)
Wieland, D. C. F. (3)
Jeong, Yongsoo (3)
Halldin, Anders (3)
Kisch, Jenö (3)
Eliasson, Alf, 1959 (3)
Hansson, Stig (3)
Svanborg, Lory Melin (3)
Olander, Julia, 1984 (3)
visa färre...
Lärosäte
Göteborgs universitet (133)
Malmö universitet (58)
Chalmers tekniska högskola (17)
Örebro universitet (3)
Uppsala universitet (2)
Linköpings universitet (2)
visa fler...
Högskolan i Halmstad (1)
Lunds universitet (1)
Karolinska Institutet (1)
visa färre...
Språk
Engelska (137)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (136)
Teknik (14)
Naturvetenskap (3)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy