21.
  • Båth, Magnus, 1974, et al. (författare)
  • Method of simulating dose reduction for digital radiographic systems.
  • 2005
  • Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 114:1-3, s. 253-9
  • Tidskriftsartikel (refereegranskat)abstract
    • The optimisation of image quality vs. radiation dose is an important task in medical imaging. To obtain maximum validity of the optimisation, it must be based on clinical images. Images at different dose levels can then either be obtained by collecting patient images at the different dose levels sought to investigate-including additional exposures and permission from an ethical committee-or by manipulating images to simulate different dose levels. The aim of the present work was to develop a method of simulating dose reduction for digital radiographic systems. The method uses information about the detective quantum efficiency and noise power spectrum at the original and simulated dose levels to create an image containing filtered noise. When added to the original image this results in an image with noise which, in terms of frequency content, agrees with the noise present in an image collected at the simulated dose level. To increase the validity, the method takes local dose variations in the original image into account. The method was tested on a computed radiography system and was shown to produce images with noise behaviour similar to that of images actually collected at the simulated dose levels. The method can, therefore, be used to modify an image collected at one dose level so that it simulates an image of the same object collected at any lower dose level.
  •  
22.
  • Båth, Magnus, 1974, et al. (författare)
  • Nodule detection in digital chest radiography: effect of anatomical noise.
  • 2005
  • Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 114:1-3, s. 109-13
  • Tidskriftsartikel (refereegranskat)abstract
    • The image background resulting from imaged anatomy can be divided into those components that are meaningful to the observers, in the sense that they are recognised as separate structures, and those that are not. These latter components (reffered to as anatomical noise) can be removed using a method developed within the RADIUS group. The aim of the present study was to investigate whether the removal of the anatomical noise results in images where lung nodules with lower contrast can be detected. A receiver operating characteristic (ROC) study was therefore conducted using two types of images: clinical chest images and chest images in which the anatomical noise had been removed. Simulated designer nodules with a full-width-at-fifth-maximum of 10 mm but with varying contrast were added to the images. The contrast needed to obtain an area under the ROC curve of 0.80, C0.8, was used as a measure of detectability (a low value of C0.8 represents a high detectability). Five regions of the chest X ray were investigated and it was found that in all regions the removal of anatomical noise led to images with lower C0.8 than the original images. On average, C0.8 was 20% higher in the original images, ranging from 7% (the lateral pulmonary regions) to 41% (the upper mediastinal regions).
  •  
23.
  • Båth, Magnus, 1974, et al. (författare)
  • Nodule detection in digital chest radiography: introduction to the RADIUS chest trial.
  • 2005
  • Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 114:1-3, s. 85-91
  • Tidskriftsartikel (refereegranskat)abstract
    • Most digital radiographic systems of today have wide latitude and are hence able to provide images with a small constraint on dose level. This opens up for an unprejudiced dose optimisation. However, in order to succeed in the optimisation task, good knowledge of the imaging and detection processes is needed. As a part of the European-wide research project 'unification of physical and clinical requirements for medical X-ray imaging'-governed by the Radiological Imaging Unification Strategies (RADIUS) Group-a major image quality trial was conducted by members of the group. The RADIUS chest trial was focused on the detection of lung nodules in digital chest radiography with the aims of determining to what extent (1) the detection of a nodule is dependent on its location, (2) the system noise disturbs the detection of lung nodules, (3) the anatomical noise disturbs the detection of lung nodules and (4) the image background and anatomical background act as pure noise for the detection of lung nodules. The purpose of the present paper is to give an introduction to the trial and describe the framework and set-up of the investigation.
  •  
24.
  • Båth, Magnus, 1974, et al. (författare)
  • Nodule detection in digital chest radiography: part of image background acting as pure noise.
  • 2005
  • Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 114:1-3, s. 102-8
  • Tidskriftsartikel (refereegranskat)abstract
    • There are several factors that influence the radiologist's ability to detect a specific structure/lesion in a radiograph. Three factors that are commonly known to be of major importance are the signal itself, the system noise and the projected anatomy. The aim of this study was to determine to what extent the image background acts as pure noise for the detection of subtle lung nodules in five different regions of the chest. A receiver operating characteristic (ROC) study with five observers was conducted on two different sets of images, clinical chest X-ray images and images with a similar power spectrum as the clinical images but with a random phase spectrum, resulting in an image background containing pure noise. Simulated designer nodules with a full-width-at-fifth-maximum of 10 mm but with varying contrasts were added to the images. As a measure of the part of the image background that acts as pure noise, the ratio between the contrast needed to obtain an area under the ROC curve of 0.80 in the clinical images to that in the random-phase images was used. The ratio ranged from 0.40 (in the lateral pulmonary regions) to 0.83 (in the hilar regions) indicating that there was a large difference between different regions regarding to what extent the image background acted as pure noise; and that in the hilar regions the image background almost completely acted as pure noise for the detection of 10 mm nodules.
  •  
25.
  • Båth, Magnus, 1974, et al. (författare)
  • RETROSPECTIVE ESTIMATION OF PATIENT DOSE-AREA PRODUCT IN THORACIC SPINE TOMOSYNTHESIS PERFORMED USING VOLUMERAD.
  • 2016
  • Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 1742-3406 .- 0144-8420. ; 169:1-4
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of this study was to evaluate the use of a recently developed method of retrospectively estimating the patient dose-area product (DAP) of a chest tomosynthesis examination, performed using VolumeRAD, in thoracic spine tomosynthesis and to determine the necessary field-size correction factor. Digital imaging and communications in medicine (DICOM) data for the projection radiographs acquired during a thoracic spine tomosynthesis examination were retrieved directly from the modality for 17 patients. Using the previously developed method, an estimated DAP for the tomosynthesis examination was determined from DICOM data in the scout image. By comparing the estimated DAP with the actual DAP registered for the projection radiographs, a field-size correction factor was determined. The field-size correction factor for thoracic spine tomosynthesis was determined to 0.92. Applying this factor to the DAP estimated retrospectively, the maximum difference between the estimated DAP and the actual DAP was <3 %. In conclusion, the previously developed method of retrospectively estimating the DAP in chest tomosynthesis can be applied to thoracic spine tomosynthesis.
  •  
26.
  • Båth, Magnus, 1974, et al. (författare)
  • VGC analysis: Application of the ROC methodology to visual grading tasks
  • 2008
  • Ingår i: Progress in Biomedical Optics and Imaging - Proceedings of SPIE. - : SPIE. - 1605-7422. ; 6917
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • To determine clinical image quality in radiography, visual grading of the reproduction of important anatomical landmarks is often used. The rating data from the observers in a visual grading study with multiple scale steps is ordinal, meaning that non-parametric rank-invariant statistical methods are required. However, many visual grading methods incorrectly use parametric statistical methods. This work describes how the methodology developed in receiver operating characteristics (ROC) analysis for characterising the difference in the observer's response to the signal and no-signal distributions can be applied to visual grading data for characterising the difference in perceived image quality between two systems. The method is termed visual grading characteristics (VGC) analysis. In a VGC study, the task of the observer is to rate her confidence about the fulfilment of image quality criteria. Using ROC software, the given ratings for the two systems are then used to determine the VGC curve, which describes the relationship between the proportions of fulfilled image criteria for the two compared systems for all possible decision thresholds. As a single measure of the difference in image quality between the two compared systems, the area under the VGC curve can be used.
  •  
27.
  • Båth, Magnus, 1974, et al. (författare)
  • VGC ANALYZER: A SOFTWARE FOR STATISTICAL ANALYSIS OF FULLY CROSSED MULTIPLE-READER MULTIPLE-CASE VISUAL GRADING CHARACTERISTICS STUDIES
  • 2016
  • Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 1742-3406 .- 0144-8420. ; 169:1-4, s. 46-53
  • Tidskriftsartikel (refereegranskat)abstract
    • Visual grading characteristics (VGC) analysis is a non-parametric rank-invariant method for analysis of visual grading data. In VGC analysis, image quality ratings for two different conditions are compared by producing a VGC curve, similar to how the ratings for normal and abnormal cases in receiver operating characteristic (ROC) analysis are used to create an ROC curve. The use of established ROC software for the analysis of VGC data has therefore previously been proposed. However, the ROC analysis is based on the assumption of independence between normal and abnormal cases. In VGC analysis, this independence cannot always be assumed, e.g. if the ratings are based on the same patients imaged under both conditions. A dedicated software intended for analysis of VGC studies, which takes possible dependencies between ratings into account in the statistical analysis of a VGC study, has therefore been developed. The software-VGC Analyzer-determines the area under the VGC curve and its uncertainty using non-parametric resampling techniques. This article gives an introduction to VGC Analyzer, describes the types of analyses that can be performed and instructs the user about the input and output data.
  •  
28.
  • Båth, Magnus, 1974, et al. (författare)
  • Visual grading characteristics (VGC) analysis: a non-parametric rank-invariant statistical method for image quality evaluation.
  • 2007
  • Ingår i: The British journal of radiology. - : British Institute of Radiology. - 1748-880X .- 0007-1285. ; 80:951, s. 169-76
  • Tidskriftsartikel (refereegranskat)abstract
    • Visual grading of the reproduction of important anatomical structures is often used to determine clinical image quality in radiography. However, many visual grading methods incorrectly use statistical methods that require data belonging to an interval scale. The rating data from the observers in a visual grading study with multiple ratings is ordinal, meaning that non-parametric rank-invariant statistical methods are required. This paper describes such a method for determining the difference in image quality between two modalities called visual grading characteristics (VGC) analysis. In a VGC study, the task of the observer is to rate his confidence about the fulfilment of image quality criteria. The rating data for the two modalities are then analysed in a manner similar to that used in receiver operating characteristics (ROC) analysis. The resulting measure of image quality is the VGC curve, which--for all possible thresholds of the observer for a fulfilled criterion--describes the relationship between the proportions of fulfilled image criteria for the two compared modalities. The area under the VGC curve is proposed as a single measure of the difference in image quality between two compared modalities. It is also described how VGC analysis can be applied to data from an absolute visual grading analysis study.
  •  
29.
  • Börjesson, Sara, et al. (författare)
  • A software tool for increased efficiency in observer performance studies in radiology.
  • 2005
  • Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 114:1-3, s. 45-52
  • Tidskriftsartikel (refereegranskat)abstract
    • Observer performance studies are time-consuming tasks, both for the participating observers and for the scientists collecting and analysing the data. A possible way to optimise such studies is to perform them in a completely digital environment. A software tool-ViewDEX (Viewer for Digital Evaluation of X-ray images)-has been developed in Java, enabling it to function on almost any computer. ViewDEX is designed to handle several types of studies, such as visual grading analysis (VGA), image criteria scoring (ICS) and receiver operating characteristics (ROC). The results from each observer are saved in a log file, which can be exported for further analysis in, for example, a special software for analysing ROC results. By using ViewDEX for an ROC experiment, an evaluation rate of approximately 200 images per hour can be achieved, compared to approximately 25 images per hour using hard copy evaluation. The results are obtained within minutes of completion of the viewing. The risk of human errors in the process of data collection and analysis is also minimised. The viewer has been used in a major trial containing approximately 2700 images.
  •  
30.
  • Carlander, A, et al. (författare)
  • Clinical evaluation of a dual-side readout technique computed radiography system in chest radiography of premature neonates.
  • 2008
  • Ingår i: Acta radiologica (Stockholm, Sweden : 1987). - : SAGE Publications. - 1600-0455 .- 0284-1851. ; 49:4, s. 468-74
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Recently, the dual-side readout technique has been introduced in computed radiography, leading to an increase in detective quantum efficiency (DQE) compared with the single-side readout technique. PURPOSE: To evaluate if the increase in DQE with the dual-side readout technique results in a higher clinical image quality in chest radiography of premature neonates at no increase in radiation dose. MATERIAL AND METHODS: Twenty-four chest radiographs of premature neonates were collected from both a single-side readout technique system and a double-side readout technique system. The images were processed in the same image-processing station in order for the comparison to be only dependent on the difference in readout technique. Five radiologists rated the fulfillment of four image quality criteria, which were based on important anatomical landmarks. The given ratings were analyzed using visual grading characteristics (VGC) analysis. RESULTS: The VGC analysis showed that the reproduction of the carina with the main bronchi and the thoracic vertebrae behind the heart was better with the dual-side readout technique, whereas no significant difference for the reproduction of the central vessels or the peripheral vessels could be observed. CONCLUSIONS: The results indicate that the higher DQE of the dual-side readout technique leads to higher clinical image quality in chest radiography of premature neonates at no increase in radiation dose.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 21-30 av 148
Typ av publikation
Typ av innehåll
refereegranskat (127)
övrigt vetenskapligt/konstnärligt (21)
Författare/redaktör
Månsson, Lars Gunnar ... (62)
Johnsson, Åse (Allan ... (36)
Svalkvist, Angelica (34)
Vikgren, Jenny, 1957 (30)
Håkansson, Markus (23)
visa fler...
Kheddache, Susanne, ... (21)
Tingberg, Anders (20)
Mattsson, Sören (16)
Sund, Patrik (15)
Söderman, Christina (13)
Flinck, Agneta, 1953 (13)
Ruschin, Mark (12)
Rossi-Norrlund, Raun ... (11)
Hansson, Jonny (11)
Molnar, David (10)
Boijsen, Marianne, 1 ... (10)
Ivarsson, Jonas, 197 ... (9)
Hemdal, Bengt (9)
Thilander-Klang, Ann ... (9)
Zachrisson, Sara (9)
Grahn, Anna (9)
Rystedt, Hans, 1951 (8)
Lundh, Charlotta, 19 ... (8)
Andersson, Ingvar (8)
Börjesson, Sara (8)
Asplund, Sara, 1976 (7)
Fisichella, Valeria ... (7)
Medin, Joakim (5)
Timberg, Pontus (5)
Bernhardt, Peter, 19 ... (5)
Börjesson, S (4)
Besjakov, Jack (4)
Almén, Anja, 1964 (4)
Robinson, J. (3)
Svensson, S (3)
Alm Carlsson, Gudrun ... (3)
Sandborg, Michael, 1 ... (3)
Hellström, Mikael, 1 ... (3)
Almén, Anja (3)
Sandblom, Viktor, 19 ... (3)
Mattsson, S. (3)
Svensson, Johanna (3)
Svahn, Tony (3)
Söderberg, Jonas (3)
Thompson, N. (3)
Cederblad, Åke, 1947 (3)
Ullman, Gustaf (3)
Svensson, Sune (3)
Starck, Sven-Åke (3)
visa färre...
Lärosäte
Göteborgs universitet (148)
Lunds universitet (23)
Linköpings universitet (7)
Uppsala universitet (4)
Jönköping University (3)
Örebro universitet (2)
visa fler...
Karolinska Institutet (2)
Chalmers tekniska högskola (1)
RISE (1)
visa färre...
Språk
Engelska (148)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (146)
Teknik (9)
Naturvetenskap (5)
Samhällsvetenskap (5)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy