SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Inganäs Olle) "

Sökning: WFRF:(Inganäs Olle)

  • Resultat 41-50 av 542
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
41.
  • Andersson, Viktor (författare)
  • Electron tomography and optical modelling for organic solar cells
  • 2012
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Organic solar cells using carbon based materials have the potential to deliver cheap solar electricity. The aim is to be able to produce solar cells with common printing techniques on flexible substrates, and as organic materials can be made soluble in various solvents, they are well adapted to such techniques. There is a large variation of organic materials produced for solar cells, both small molecules and polymers. Alterations of the molecular structure induce changes of the electrical and optical properties, such as band gap, mobility and light absorption. During the development of organic solar cells, the step of mixing of an electron donor and an electron acceptor caused a leap in power conversion efficiency improvement, due to an enhanced exciton dissociation rate. Top performing organic solar cells now exhibit a power conversion efficiency of over 10%. Currently, a mix of a conjugated polymer, or smaller molecule, and a fullerene derivative are commonly used as electron donor and acceptor. Here, the blend morphology plays an important role. Excitons formed in either of the donor or acceptor phase need to diffuse to the vicinity of the donor-acceptor interface to efficiently dissociate. Exciton diffusion lengths in organic materials are usually in the order of 5-10 nm, so the phases should not be much larger than this, for good exciton quenching. These charges must also be extracted, which implies that a network connected to the electrodes is needed. Consequently, a balance of these demands is important for the production of efficient organic solar cells.Morphology has been found to have a significant impact on the solar cell behaviour and has thus been widely studied. The aim of this work has been to visualize the morphology of active layers of organic solar cells in three dimensions by the use of electron tomography. The technique has been applied to materials consisting of conjugated polymers blended with fullerene derivatives. Though the contrast in these blends is poor, three-dimensional reconstructions have been produced, showing the phase formation in three dimensions at the scale of a few nanometres. Several material systems have been investigated and preparation techniques compared.Even if excitons are readily dissociated and paths for charge extraction exist, the low charge mobilities of many materials put a limit on film thickness. Although more light could be absorbed by increased film thickness, performance is hampered due to increased charge recombination. A large amount of light is thus reflected and not used for energy conversion. Much work has been put into increasing the light absorption without hampering the solar cell performance. Aside from improved material properties, various light trapping techniques have been studied. The aim is here to increase the optical path length in the active layer, and in this way improve the absorption without enhanced extinction coefficient.At much larger dimensions, light trapping in solar cells with folded configuration has been studied by the use of optical modelling. An advantage of these V-cells is that two materials with complementing optical properties may be used together to form a tandem solar cell, which may be connected in either serial or parallel configuration, with maintained light trapping feature. In this work optical absorption in V-cells has been modelled and compared to that of planar ones.
  •  
42.
  • Andersson, Viktor, et al. (författare)
  • Full day modelling of V-shaped organic solar cell
  • 2011
  • Ingår i: Solar Energy. - : Elsevier Science B.V., Amsterdam.. - 0038-092X .- 1471-1257. ; 85:6, s. 1257-1263
  • Tidskriftsartikel (refereegranskat)abstract
    • Folded and planar solar cells are examined with optical simulations, with the finite element method. The maximum photocurrent densities during the full day are compared between cells of different geometries and tilting angles. The change of incident angle and spectrum over time are handled in this analysis. The results show that the light trapping effect of the folded cell makes these cells show higher maximum photocurrent densities than the planar cells during all hours of the day. This is the case for both single and tandem cells. The results also indicate that balancing the currents in the tandem cells by adjusting the active layer thickness may be more cumbersome with the folded tandem cells than the stacked planar cells.
  •  
43.
  • Andersson, Viktor, et al. (författare)
  • Imaging of the 3D Nanostructure of a Polymer Solar Cell by Electron Tomography
  • 2009
  • Ingår i: Nano letters (Print). - : American Chemical Society (ACS). - 1530-6984 .- 1530-6992. ; 9:2, s. 853-855
  • Tidskriftsartikel (refereegranskat)abstract
    • Electron tomography has been used for analyzing the active layer in a polymer solar cell, a bulk heterojunction of an alternating copolymer of fluorene and a derivative of fullerene. The method supplies a three-dimensional representation of the morphology of the film, where domains with different scattering properties may be distinguished. The reconstruction shows good contrast between the two phases included in the film and demonstrates that electron tomography is an adequate tool for investigations of the three-dimensional nanostructure of the amorphous materials used in polymer solar cells.
  •  
44.
  • Andersson, Viktor, et al. (författare)
  • Morphology of organic electronic materials imaged via electron tomography
  • 2012
  • Ingår i: Journal of Microscopy. - : Wiley. - 0022-2720 .- 1365-2818. ; 247:3, s. 277-287
  • Tidskriftsartikel (refereegranskat)abstract
    • Several organic materials and blends have been studied with the use of electron tomography. Tomography reconstructions of active layers of organic solar cells, where various preparation techniques have been used, have been analysed and compared to device behaviour. In addition, materials with predefined structures, including contrast enhancing features, have been studied and double tilt data collection has been employed to improve reconstructions. Small changes in preparation procedures may lead to large differences in morphology and device performance, and the results also indicate a complex relation between these.
  •  
45.
  • Andersson, Viktor, et al. (författare)
  • Optical modeling of a folded organic solar cell
  • 2008
  • Ingår i: Journal of Applied Physics. - : AIP Publishing. - 0021-8979 .- 1089-7550. ; 103:9, s. 094520-
  • Tidskriftsartikel (refereegranskat)abstract
    • The optical behavior of a reflective tandem solar cell (V cell) is modeled by means of finite element method (FEM) simulations. The absorption of solar light in the active material as well as in both electrode layers is calculated. The FEM solves the electromagnetic wave equation on the entire defined geometry, resulting in the consideration of interference effects, as well as effects of refraction and reflection. Both single cells and tandem cells are modeled and confirmed to be in accordance with reflectance measurements. Energy dissipation in the active layers is studied as a function of layer thickness and folding angle, and the simulations clearly display the advantage of the light trapping feature of folded cells. This is especially prominent in cells with thinner active layers, where folding induces absorption in the active layer equivalent to that of much thicker cells.
  •  
46.
  • Asberg, D.P., et al. (författare)
  • PEDOT/PSS hydrogel networks as 3-D enzyme electrodes
  • 2003
  • Konferensbidrag (refereegranskat)abstract
    • A mesoscopic network in the form of a hydrogel of the highly conductive polymer PEDOT/PSS hydrogel was used in an enzyme electrode setup. Osmium was used both as a crosslink point in the hydrogel network and as a mediator between the prosthetic group of the enzyme and the conductive polymer matrix. Both biostability and high conductivity is important aspects when building nerve- or cell- electrodes. Diffusion of analytes surrounding the cells into the matrix electrode is feasible due to the open hydrogel structure. The high water content in these structures is important when buffering them to a pH of choice.
  •  
47.
  • Asplund, Maria, 1978-, et al. (författare)
  • Biocompatibility of PEDOT/biomolecular composites intended for neural communication electrodes
  • Annan publikation (populärvet., debatt m.m.)abstract
    • Electrodes of the conjugated polymer poly(3,4-ethylene dioxythiophene) (PEDOT) have been shown to possess very attractive electrochemical properties for functional electrical stimulation (FES) or recording in the nervous system. Biomolecules already present in nervous tissue, added as counter ions in PEDOT electropolymerisation, could be a route to further improve the biomaterial properties of PEDOT, eliminating the need of surfactant counter ions like docedyl benzene sulphonate (DBS) or polystyrene sulphonate (PSS) in the polymerisation process. Such PEDOT/biomolecular composites using heparin, or hyaluronic acid, have been electrochemically investigated in a previous study and have been shown to retain the attractive electrochemical properties already proven for PEDOT:PSS.   The aim of the present study is to evaluate biocompatibility of these PEDOT/biomolecular composites in vitro and also evaluate PEDOT:heparin biocompatibility in cortical tissue in vivo. Hereby, we also aim to identify a suitable test protocol, that can be used in future evaluations when further material developments are made.   Material toxicity was first tested on cell lines, both through a standardised agarose overlay assay on L929 fibroblasts, and through elution tests on human neuroblastoma SH-SY5Y cells. Subsequently, a biocompatibility in vivo test was performed using PEDOT:heparin coated platinum probes implanted in the cerebral cortex of Sprague-Dawley rats. Tissue was collected at three weeks and six weeks of implantation and evaluated by immunohistochemistry.   No cytotoxic response was seen to any of the PEDOT:biomolecular composites tested here. Furthermore, elution tests were found to be a practical and effective way of screening materials for toxicity and had a clear advantage over the agarose overlay assay, which was difficult to apply on other cell types than fibroblasts. Elution tests would therefore be recommendable as a screening method, at all stages of material development. In the in vivo tests, the stiffness of the platinum substrate was a significant problem, and extensive glial scarring was seen in most cases irrespective of implant material. However, quantification of immunological response through distance measurements from implant site to closest neuron, and counting of macrophage densities in proximity to polymer surface, was comparable to those of platinum controls. These results indicate that PEDOT:heparin surfaces were as compatible with cortical tissue as pure platinum controls.
  •  
48.
  • Asplund, Maria, 1978-, et al. (författare)
  • Composite biomolecule/PEDOT materials for neural electrodes
  • 2008
  • Ingår i: Biointerphases. - NY : American Institute of Physics. - 1559-4106 .- 1934-8630. ; 3:3, s. 83-93
  • Tidskriftsartikel (refereegranskat)abstract
    • Electrodes intended for neural communication must be designed to meet boththe electrochemical and biological requirements essential for long term functionality. Metallic electrode materials have been found inadequate to meet theserequirements and therefore conducting polymers for neural electrodes have emergedas a field of interest. One clear advantage with polymerelectrodes is the possibility to tailor the material to haveoptimal biomechanical and chemical properties for certain applications. To identifyand evaluate new materials for neural communication electrodes, three chargedbiomolecules, fibrinogen, hyaluronic acid (HA), and heparin are used ascounterions in the electrochemical polymerization of poly(3,4-ethylenedioxythiophene) (PEDOT). The resultingmaterial is evaluated electrochemically and the amount of exposed biomoleculeon the surface is quantified. PEDOT:biomolecule surfaces are also studiedwith static contact angle measurements as well as scanning electronmicroscopy and compared to surfaces of PEDOT electrochemically deposited withsurfactant counterion polystyrene sulphonate (PSS). Electrochemical measurements show that PEDOT:heparinand PEDOT:HA, both have the electrochemical properties required for neuralelectrodes, and PEDOT:heparin also compares well to PEDOT:PSS. PEDOT:fibrinogen isfound less suitable as neural electrode material.
  •  
49.
  • Asplund, Maria, 1978- (författare)
  • Conjugated Polymers for Neural Interfaces : Prospects, possibilities and future challenges
  • 2009
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Within the field of neuroprosthetics the possibility to use implanted electrodes for communication with the nervous system is explored. Much effort is put into the material aspects of the electrode implant to increase charge injection capacity, suppress foreign body response and build micro sized electrode arrays allowing close contact with neurons. Conducting polymers, in particular poly(3,4-ethylene dioxythiophene) (PEDOT), have been suggested as materials highly interesting for such neural communication electrodes. The possibility to tailor the material both mechanically and biochemically to suit specific applications, is a substantial benefit with polymers when compared to metals. PEDOT also have hybrid charge transfer properties, including both electronic and ionic conduction, which allow for highly efficient charge injection.   Part of this thesis describes a method of tailoring PEDOT through exchanging the counter ion used in electropolymerisation process. Commonly used surfactants can thereby be excluded and instead, different biomolecules can be incorporated into the polymer. The electrochemical characteristics of the polymer film depend on the ion. PEDOT electropolymerised with heparin was here determined to have the most advantageous properties. In vitro methods were applied to confirm non-cytotoxicity of the formed PEDOT:biomolecular composites. In addition, biocompatibility was affirmed for PEDOT:heparin by evaluation of inflammatory response and neuron density when implanted in rodent cortex.   One advantage with PEDOT often stated, is its high stability compared to other conducting polymers. A battery of tests simulating the biological environment was therefore applied to investigate this stability, and especially the influence of the incorporated heparin. These tests showed that there was a decline in the electroactivity of PEDOT over time. This also applied in phosphate buffered saline at body temperature and in the absence of other stressors. The time course of degradation also differed depending on whether the counter ion was the surfactant polystyrene sulphonate or heparin, with a slightly better stability for the former.   One possibility with PEDOT, often overlooked for biological applications, is the use of its semi conducting properties in order to include logic functions in the implant. This thesis presents the concept of using PEDOT electrochemical transistors to construct textile electrode arrays with in-built multiplexing. Using the electrolyte mediated interaction between adjacent PEDOT coated fibres to switch the polymer coat between conducting and non conducting states, then transistor function can be included in the conducting textile. Analogue circuit simulations based on experimentally found transistor characteristics proved the feasibility of these textile arrays. Developments of better polymer coatings, electrolytes and encapsulation techniques for this technology, were also identified to be essential steps in order to make these devices truly useful.   In summary, this work shows the potential of PEDOT to improve neural interfaces in several ways. Some weaknesses of the polymer and the polymer electronics are presented and this, together with the epidemiological data, should point in the direction for future studies within this field.
  •  
50.
  • Asplund, Maria, et al. (författare)
  • Construction of wire electrodesand 3D woven logicas a potential technology forneuroprosthetic implants
  • 2008
  • Ingår i: IEEE Transactions on Biomedical Engineering. - 0018-9294 .- 1558-2531.
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • New strategies to improve neuron coupling to neuroelectronic implants are needed. In particular, tomaintain functional coupling between implant and neurons, foreign body response like encapsulation must meminimized. Apart from modifying materials to mitigate encapsulation it has been shown that with extremely thinstructures, encapsulation will be less pronounced. We here utilize wire electrochemical transistors (WECTs) usingconducting polymer coated fibers. Monofilaments down to 10 μm can be successfully coated and weaved intocomplex networks with built in logic functions, so called textile logic. Such systems can control signal patterns at alarge number of electrode terminals from a few addressing fibres. Not only is fibre size in the range where lessencapsulation is expected but textiles are known to make successful implants because of their soft and flexiblemechanical properties. Further, textile fabrication provides versatility and even three dimensional networks arepossible. Three possible architectures for neuroelectronic systems are discussed. WECTs are sensitive to dehydrationand materials for better durability or improved encapsulation is needed for stable performance in biologicalenvironments.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 41-50 av 542
Typ av publikation
tidskriftsartikel (416)
konferensbidrag (58)
doktorsavhandling (35)
forskningsöversikt (13)
annan publikation (12)
bokkapitel (8)
visa fler...
visa färre...
Typ av innehåll
refereegranskat (445)
övrigt vetenskapligt/konstnärligt (93)
populärvet., debatt m.m. (4)
Författare/redaktör
Inganäs, Olle (427)
Inganäs, Olle, 1951- (89)
Zhang, Fengling (79)
Andersson, Mats, 196 ... (58)
Andersson, M.R. (35)
Andersson, Mats R (35)
visa fler...
Wang, Ergang, 1981 (33)
Berggren, Magnus (31)
Tang, Zheng (27)
Zhang, Fengling, 196 ... (23)
Solin, Niclas (23)
Xia, Yuxin (22)
Vandewal, Koen (21)
Sundström, Villy (20)
Yartsev, Arkady (20)
Gao, Feng (20)
Elfwing, Anders (19)
Svensson, M. (18)
Melianas, Armantas (18)
Theander, M. (18)
Nilsson, Peter (17)
Andersson, Mattias (17)
Hamedi, Mahiar (16)
Musumeci, Chiara (14)
Herland, Anna (14)
Johansson, Tomas (13)
Müller, Christian, 1 ... (13)
Admassie, Shimelis (13)
Tress, Wolfgang (13)
Inganäs, Olle, Profe ... (12)
Muller, Christian (12)
Ma, Zaifei (12)
Ajjan, Fátima (11)
Björk, Per (11)
Andersson, Viktor (11)
Perzon, Erik (10)
Mammo, Wendimagegn, ... (10)
Ouyang, Liangqi (10)
Hjertberg, T. (10)
Nyberg, Tobias (10)
Zhou, Yi (10)
Pettersson, Lars (9)
Gustafsson, Göran (9)
Gabrielsson, Roger (9)
Lundström, Ingemar (9)
Ederth, Thomas (9)
Persson, Nils-Kriste ... (9)
Tvingstedt, Kristofe ... (9)
Wennerström, O. (9)
Granström, Magnus (9)
visa färre...
Lärosäte
Linköpings universitet (525)
Chalmers tekniska högskola (76)
Lunds universitet (39)
Kungliga Tekniska Högskolan (27)
Karlstads universitet (10)
Karolinska Institutet (10)
visa fler...
Sveriges Lantbruksuniversitet (3)
Umeå universitet (2)
Uppsala universitet (2)
RISE (2)
Göteborgs universitet (1)
Högskolan i Borås (1)
visa färre...
Språk
Engelska (539)
Svenska (2)
Odefinierat språk (1)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (228)
Teknik (76)
Medicin och hälsovetenskap (5)
Lantbruksvetenskap (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy