SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

Nicaragua
 

Sökning: Nicaragua > Engelska > Mälardalens universitet > Cost-reliability an...

Cost-reliability analysis of hybrid pumped-battery storage for solar and wind energy integration in an island community

Canales, Fausto A. (författare)
Univ Costa, Dept Civil & Environm, Calle 58 55-66, Barranquilla 080002, Atlantico, Colombia.
Jurasz, Jakob, PhD, 1990- (författare)
Mälardalens universitet,Framtidens energi,AGH Univ Sci & Technol, Fac Management, Dept Engn Management, 30 Mickiewicza Ave, PL-30059 Krakow, Poland.
Guezgouz, Mohammed (författare)
Mostaganem Univ, Dept Elect Engn, BP188-227, Mostaganem 27000, Algeria.
visa fler...
Beluco, Alexandre (författare)
Univ Fed Rio Grande do Sul, Inst Pesquisas Hidraulicas, Porto Alegre, RS, Brazil.
visa färre...
Univ Costa, Dept Civil & Environm, Calle 58 55-66, Barranquilla 080002, Atlantico, Colombia Framtidens energi (creator_code:org_t)
ELSEVIER, 2021
2021
Engelska.
Ingår i: Sustainable Energy Technologies and Assessments. - : ELSEVIER. - 2213-1388 .- 2213-1396. ; 44
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • This paper presents a mathematical model for estimating the optimal sizing and assessing a standalone hybrid power system's performance entirely based on variable renewable energy sources and coupled with a hybrid energy storage system. This study evaluates how different levels of the main components' capital cost and the loss of power supply probability would affect the cost of energy and the power system's optimal sizing. The case study selected for this study was Ometepe Island in Nicaragua, where the crater lake of an extinct volcano was considered a feasible upper reservoir of a pumped storage hydropower plant, reducing the investments associated with this component. The mathematical formulation considers energy storage losses and gains, and the Pareto efficient solutions of the multi-objective optimization model simultaneously increase reliability, reduce the cost of energy, and minimize curtailment energy. By employing time-series with an hourly resolution, the model allows assessing the impact of the interannual variability of renewable energy sources on the system's performance. As for the case study, the cost of energy obtained from the model results ranges between (sic)0.047/kWh and (sic)0.095/kWh, based on international reference values, and these values match the information available in the literature and other databases.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)

Nyckelord

Hybrid power systems
Multi-objective optimization
Hybrid energy storage
Reliability
Energy management strategy

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy