SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Wennerberg Ann 1955 ) ;lar1:(cth);pers:(Kjellin Per)"

Sökning: WFRF:(Wennerberg Ann 1955 ) > Chalmers tekniska högskola > Kjellin Per

  • Resultat 1-8 av 8
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Arvidsson, Anna, 1973, et al. (författare)
  • Formation of calcium phosphates on titanium implants with four different bioactive surface preparations. An in vitro study
  • 2007
  • Ingår i: Journal of Materials Science-Materials in Medicine. - : Springer Science and Business Media LLC. - 0957-4530 .- 1573-4838. ; 18:10, s. 1945-1954
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of the present study was to compare the nucleating and growing behaviour on four types of bioactive surfaces by using the simulated body fluid (SBF) model. Titanium discs were blasted and then prepared by alkali and heat treatment, anodic oxidation, fluoridation, or hydroxyapatite coating. The discs were immersed in SBF for 1, 2, 4 and 6 weeks. Calcium phosphates were found on all specimens, as analysed with scanning electron microscopy/energy dispersive X-ray analysis (SEM/EDX). After 1 and 2 weeks of SBF immersion more titanium was accessible with SEM/EDX on the blasted surfaces than the four bioactive surface types, indicating a difference in coverage by calcium phosphates. The Ca/P mean ratio of the surfaces was approximately 1.5 after 1 week, in contrast to the fluoridated specimens which displayed a Ca/P mean ratio of approximately 2. Powder X-ray diffraction (P-XRD) analyses showed the presence of hydroxyapatite on all types of surfaces after 4 and 6 weeks of immersion. The samples immersed for 6 weeks showed a higher degree of crystallinity than the samples immersed for 4 weeks. In conclusion, differences appeared at the early SBF immersion times of 1 and 2 weeks between controls and bioactive surface types, as well as between different bioactive surface types.
  •  
2.
  • Franke Stenport, Victoria, 1970, et al. (författare)
  • Precipitation of calcium phosphate in the presence of albumin on titanium implants with four different possibly bioactive surface preparations. An in vitro study
  • 2008
  • Ingår i: Journal of Materials Science: Materials in Medicine. - : Springer Science and Business Media LLC. - 0957-4530 .- 1573-4838. ; 19:12, s. 3497-3505
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of the present study was to compare the nucleating behaviour on four types of bioactive surfaces by using the simulated body fluid (SBF) model with the presence albumin. Titanium discs were blasted (B) and then prepared by alkali and heat treatment (AH), anodic oxidation (AO), fluoridation (F), or hydroxyapatite coating (HA). The discs were immersed in SBF with 4.5 mg/ml albumin for 3 days, 1, 2, 3 and 4 weeks and analysed with scanning electron microscopy/energy dispersive X-ray analysis (SEM/EDX) and X-ray photoelectron spectroscopy (XPS). Topographic surface characterisation was performed with a contact stylus profilometer. The results demonstrated that the bioactive surfaces initiated an enhanced calcium phosphate (CaP) formation and a more rapid increase of protein content was present on the bioactive surfaces compared to the blasted control surface. The observation was present on all bioactive surfaces. The fact that there was a difference between the bioactive surfaces and the blasted control surface with respect to precipitation of CaP and protein content on the surfaces support the fact that there may be biochemical advantages in vivo by using a bioactive surface.
  •  
3.
  • Göransson, Anna, 1970, et al. (författare)
  • An in vitro comparison of possibly bioactive titanium implant surfaces.
  • 2009
  • Ingår i: Journal of Biomedical Materials Research Part A. - : Wiley. - 1552-4965 .- 1549-3296. ; 88:4, s. 1037-1047
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of the study was to compare Ca and P formation (CaP) and subsequent bone cell response of a blasted and four different possibly bioactive commercially pure (cp) titanium surfaces; 1. Fluoride etched (Fluoride), 2. Alkali-heat treated (AH), 3. Magnesium ion incorporated anodized (TiMgO), and 4. Nano HA coated and heat treated (nano HA) in vitro. Furthermore, to evaluate the significance of the SBF formed CaP coat on bone cell response. The surfaces were characterized by Optical Interferometry, Scanning Electron Microscopy (SEM) and X-ray Photoelectron Spectroscopy (XPS). CaP formation was evaluated after 12, 24 and 72 h in simulated body fluid (SBF). Primary human mandibular osteoblast-like cells were cultured on the various surfaces subjected to SBF for 72 h. Cellular attachment, differentiation (osteocalcin) and protein production (TGF-beta(1)) was evaluated after 3 h and 10 days respectively. Despite different morphological appearances, the roughness of the differently modified surfaces was similar. The possibly bioactive surfaces gave rise to an earlier CaP formation than the blasted surface, however, after 72 h the blasted surface demonstrated increased CaP formation compared to the possibly bioactive surfaces. Subsequent bone cell attachment was correlated to neither surface roughness nor the amount of formed CaP after SBF treatment. In contrast, osteocalcin and TGF-beta(1) production were largely correlated to the amount of CaP formed on the surfaces. However, bone response (cell attachment, osteocalcin and TGF-F production) on the blasted controls were similar or increased compared to the SBF treated fluoridated, AH and TiMgO surface. (c) 2008 Wiley Periodicals, Inc. J Biomed Mater Res, 2008.
  •  
4.
  • Meirelles, Luiz, 1974, et al. (författare)
  • Bone reaction to nano hydroxyapatite modified titanium implants placed in a gap-healing model
  • 2008
  • Ingår i: Journal Biomedical MAterials Research - A. - : Wiley. - 1549-3296 .- 1552-4965. ; 87:3, s. 624-631
  • Tidskriftsartikel (refereegranskat)abstract
    • Nanohydroxyapatite materials show similar chemistry to the bone apatite and depending on the underlying topography and the method of preparation, the nanohydroxyapatite may simulate the specific arrangement of the crystals in bone. Hydroxyapatite (HA) and other CaP materials have been indicated in cases in which the optimal surgical fit is not achievable during surgery, and the HA surface properties may enhance bone filling of the defect area. In this study, very smooth electropolished titanium implants were used as substrata for nano-HA surface modification and as control. One of each implant (control and nano HA) was placed in the rabbit tibia in a surgical site 0.7 mm wider than the implant diameter, resulting in a gap of 0.35 mm on each implant side. Implant stability was ensured by a fixating plate fastened with two side screws. Topographical evaluation performed with an optical interferometer revealed the absence of microstructures on both implants and higher resolution evaluation with AFM showed similar nanoroughness parameters. Surface pores detected on the AFM measurements had similar diameter, depth, and surface porosity (%). Histological evaluation demonstrated similar bone formation for the nano HA and electropolished implants after 4 weeks of healing. These results do not support that nano-HA chemistry and nanotopography will enhance bone formation when placed in a gap-healing model. The very smooth surface may have prevented optimal activity of the material and future studies may evaluate the synergic effects of the surface chemistry, micro, and nanotopography, establishing the optimal parameters for each of them.
  •  
5.
  • Meirelles, Luiz, 1974, et al. (författare)
  • Effect of hydroxyapatite and titania nanostructures on early in vivo bone response
  • 2008
  • Ingår i: Clinical Implant Dentistry and Related Research. - : Wiley. - 1708-8208 .- 1523-0899. ; 10:4, s. 245-254
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: Hydroxyapatite or titania nano structures were applied on smooth titanium implant cylinders. The aim was to investigate whether nano HA may result in enhanced osseointegration compared to nano titania structures. Material and Methods: Surface topography evaluation included detailed characterization of nano size structures present at the implant surface combined with surface roughness parameters at the micro- and nano- meter level of resolution. Microstructures were removed from the surface to ensure that bone response observed was dependent only on the nanotopography and/or chemistry of the surface. Early in vivo bone response (4 weeks) evaluation was investigated in a rabbit model. Results: In the present study, nano titania coated implants showed an increased coverage area and feature density, forming a homogenous layer compared to nano HA implants. Bone response observed at 4 weeks could not be explained by the surface chemistry. New formed bone connected to the original cortical bone demonstrated an increase of 24% for the nano titania compared to the nano HA implant, although the difference was not statistically significant. Conclusion: Thus, no evidence of enhanced bone formation to nano hydroxyapatite modified implants was observed compared to nano titania modified implants. The presence of specific nano structures; dependent on the surface modification exhibiting different size and distribution did modulate in vivo bone response.
  •  
6.
  • Meirelles, Luiz, 1974, et al. (författare)
  • Nano hydroxyapatite structures influence early bone formation
  • 2008
  • Ingår i: Journal Biomedical Materials Research - A. - : Wiley. - 1549-3296 .- 1552-4965. ; 87:2, s. 299-307
  • Tidskriftsartikel (refereegranskat)abstract
    • In a study model that aims to evaluate the effect of nanotopography on bone formation, micrometer structures known to alter bone formation, should be removed. Electropolished titanium implants were prepared to obtain a surface topography in the absence of micro structures, thereafter the implants were divided in two groups. The test group was modified with nanosize hydroxyapatite particles; the other group was left uncoated and served as control for the experiment. Topographical evaluation demonstrated increased nanoroughness parameters for the nano-HA implant and higher surface porosity compared to the control implant. The detected features had increased size and diameter equivalent to the nano-HA crystals present in the solution and the relative frequency of the feature size and diameter was very similar. Furthermore, feature density per m2 showed a decrease of 13.5% on the nano-HA implant. Chemical characterization revealed calcium and phosphorous ions on the modified implants, whereas the control implants consisted of pure titanium oxide. Histological evaluation demonstrated significantly increased bone formation to the coated (p < 0.05) compared to uncoated implants after 4 weeks of healing. These findings indicate for the first time that early bone formation is dependent on the nanosize hydroxyapatite features, but we are unaware if we see an isolated effect of the chemistry or of the nanotopography or a combination of both.
  •  
7.
  • Svanborg, Lory Melin, et al. (författare)
  • Evaluation of bone healing on sandblasted and Acid etched implants coated with nanocrystalline hydroxyapatite: an in vivo study in rabbit femur
  • 2014
  • Ingår i: International Journal of Dentistry. - : Hindawi Limited. - 1687-8728 .- 1687-8736. ; 2014
  • Tidskriftsartikel (refereegranskat)abstract
    • This study aimed at investigating if a coating of hydroxyapatite nanocrystals would enhance bone healing over time in trabecular bone. Sandblasted and acid etched titanium implants with and without a submicron thick coat of hydroxyapatite nanocrystals (nano-HA) were implanted in rabbit femur with healing times of 2, 4, and 9 weeks. Removal torque analyses and histological evaluations were performed. The torque analysis did not show any significant differences between the implants at any healing time. The control implant showed a tendency of more newly formed bone after 4 weeks of healing and significantly higher bone area values after 9 weeks of healing. According to the results from this present study, both control and nano-HA surfaces were biocompatible and osteoconductive. A submicron thick coating of hydroxyapatite nanocrystals deposited onto blasted and acid etched screw shaped titanium implants did not enhance bone healing, as compared to blasted and etched control implants when placed in trabecular bone.
  •  
8.
  • Svanborg, Lory Melin, et al. (författare)
  • The effect of hydroxyapatite nanocrystals on early bone formation surrounding dental implants.
  • 2011
  • Ingår i: International journal of oral and maxillofacial surgery. - : Elsevier BV. - 1399-0020 .- 0901-5027. ; 40:3, s. 308-15
  • Tidskriftsartikel (refereegranskat)abstract
    • The knowledge of how nanostructures might affect early bone healing and osseointegration is limited. The aim of this study was to investigate if nanometer thick coatings of hydroxyapatite nanocrystals applied on a moderately rough surface might enhance early bone healing on screw-shaped dental implants and to evaluate if the thickness of the coat influences healing. Sandblasted and acid etched titanium implants coated with two different thicknesses of hydroxyapatite (test implants) and sandblasted and acid etched titanium implants (control implants), were inserted in rabbit tibia. After a healing time of 2, 4 and 9 weeks, a removal torque analysis and a histological evaluation were performed. The results from the removal torque analysis showed a tendency for higher values for the double coated hydroxyapatite after 4 weeks and for both the coated surfaces after 9 weeks of healing. The histological evaluations indicated slightly more new bone formation with the coated implants compared with the control; the differences did not reach statistical significance. The present study could not support the importance of nanometer thick coatings of hydroxyapatite nanocrystals in early bone healing, at least not when applied on a blasted and etched surface and placed in a cortical bone.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-8 av 8

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy