SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "LAR1:gu ;mspu:(article);pers:(Båth Magnus 1974)"

Sökning: LAR1:gu > Tidskriftsartikel > Båth Magnus 1974

  • Resultat 11-20 av 148
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
11.
  • Båth, Magnus, 1974, et al. (författare)
  • A conceptual optimisation strategy for radiography in a digital environment.
  • 2005
  • Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 114:1-3, s. 230-5
  • Tidskriftsartikel (refereegranskat)abstract
    • Using a completely digital environment for the entire imaging process leads to new possibilities for optimisation of radiography since many restrictions of screen/film systems, such as the small dynamic range and the lack of possibilities for image processing, do not apply any longer. However, at the same time these new possibilities lead to a more complicated optimisation process, since more freedom is given to alter parameters. This paper focuses on describing an optimisation strategy that concentrates on taking advantage of the conceptual differences between digital systems and screen/film systems. The strategy can be summarised as: (a) always include the anatomical background during the optimisation, (b) perform all comparisons at a constant effective dose and (c) separate the image display stage from the image collection stage. A three-step process is proposed where the optimal setting of the technique parameters is determined at first, followed by an optimisation of the image processing. In the final step the optimal dose level-given the optimal settings of the image collection and image display stages-is determined.
  •  
12.
  •  
13.
  •  
14.
  • Båth, Magnus, 1974, et al. (författare)
  • Determination of the two-dimensional detective quantum efficiency of a computed radiography system.
  • 2003
  • Ingår i: Medical physics. - : Wiley. - 0094-2405. ; 30:12, s. 3172-82
  • Tidskriftsartikel (refereegranskat)abstract
    • Based on a recently described method for determining the two-dimensional presampling modulation transfer function (MTF), the aperture mask method, a method for determining the two-dimensional detective quantum efficiency (DQE) of a digital radiographic system was developed. The method was applied to a new computed radiography (CR) system and comparisons with one-dimensional determinations of the presampling MTF and the DQE were performed. The aperture mask method was shown to agree with the conventional tilted slit method for determining the presampling MTF along the axes. For the particular CR system studied, the mean of one-dimensional determinations of the DQE in orthogonal directions led to a representative measure of the average DQE behavior of the system up to the Nyquist frequency along the axes, but a deviation was observed above this frequency. In conclusion, the method developed for determining the two-dimensional DQE can be used to determine the imaging properties of a digital radiographic detector system over almost the entire frequency domain, the exception being the lowest frequencies (< or = 0.1 mm(-1)) at which the validity and the reliability of the method are low.
  •  
15.
  • Båth, Magnus, 1974, et al. (författare)
  • Effective dose to patients from chest examinations with tomosynthesis
  • 2010
  • Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 1742-3406 .- 0144-8420. ; 139:1-3, s. 153-158
  • Tidskriftsartikel (refereegranskat)abstract
    • Chest tomosynthesis, which refers to the principle of collecting low-dose projections of the chest at different angles and using these projections to reconstruct section images of the chest, is an imaging technique recently introduced to health care. The main purpose of the present work was to determine the average effective dose to patients from clinical use of chest tomosynthesis. Exposure data for two chest radiography laboratories with tomosynthesis option (Definium 8000 with VolumeRAD option, GE Healthcare, Chalfont St. Giles, UK) were registered for 20 patients with a weight between 60 and 80 kg (average weight of 70.2 kg). The recorded data were used in the Monte Carlo program PCXMC 2.0 (STUK-Radiation and Nuclear Safety Authority, Helsinki, Finland) to determine the average effective dose for each projection. The effective dose for the chest tomosynthesis examination, including a scout view and the tomosynthesis acquisition, was finally obtained by adding the effective doses from all projections. Using the weighting factors given in ICRP 103, the average effective dose for the examination was found to be 0.13 mSv, whereas the average effective dose for the conventional two-view chest radiography examination was 0.05 mSv. A conversion factor of 0.26 mSv Gy(-1) cm(-2) was found suitable for determining the effective dose from a VolumeRAD chest tomosynthesis examination from the total registered kerma-area product. In conclusion, the effective dose to a standard-sized patient (170 cm/70 kg) from a VolumeRAD chest tomosynthesis examination is ~2 % of an average chest CT and only two to three times the effective dose from the conventional two-view chest radiography examination.
  •  
16.
  • Båth, Magnus, 1974 (författare)
  • Evaluating imaging systems: practical applications
  • 2010
  • Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 1742-3406 .- 0144-8420. ; 139:1-3, s. 26-36
  • Tidskriftsartikel (refereegranskat)abstract
    • There are many ways in which imaging systems can be evaluated. The aim of the present paper is to provide an overview of a number of selected approaches to evaluating imaging systems, often encountered by the medical physicist, and discuss their validity and reliability. Specifically, it will cover (i) characterisation of an imaging system in terms of its detective quantum efficiency using linear-systems analysis; (ii) attempts to calculate relevant measures directly in images using the Rose model and the pixel signal-to-noise ratio; (iii) task-based methods incorporating human observers such as receiver-operating characteristics and (iv) visual grading-based methods using experienced radiologists as observers.
  •  
17.
  • Båth, Magnus, 1974, et al. (författare)
  • Evaluation of the imaging properties of two generations of a CCD-based system for digital chest radiography.
  • 2002
  • Ingår i: Medical physics. - : Wiley. - 0094-2405. ; 29:10, s. 2286-97
  • Tidskriftsartikel (refereegranskat)abstract
    • Two generations of a CCD-based detector system with lens-based optical coupling for digital chest radiography were evaluated in terms of presampling MTF, NPS, NEQ, DQE, linearity in response, and SNR over the detector area. Measurements were performed over a wide exposure range and at several different beam qualities. Neither the presampling MTF nor the DQE showed any general strong beam quality dependence, whereas the NPS and NEQ did when compared at specific entrance air kerma values. The exposure dependency for the DQE was found to be considerable, with the detectors showing low DQE at low exposures, and higher DQE at higher exposures. It was found that the second generation has been substantially improved compared to its predecessor regarding all the relevant parameters. The DQE(0) at an entrance air kerma of 5 microGy increased from 9% to 15%, mainly due to a better system gain (including optical coupling efficiency and matching of the energy of the emitted light photons to the sensitivity of the CCD camera). The first generation of detectors was found to have problems with bad peripheral resolution [MTF(muN/2) <0.1]. This problem was nonexistent for the second generation for which uniform resolution has been obtained [MTF(muN/2)=0.3]. A theoretical calculation of the DQE of two model systems similar to the ones evaluated was also performed, and the results were comparable to the experimentally determined data at high exposures. The model shows that both systems suffer from low optical coupling efficiency due to the large demagnification used. The main conclusion is that although the second generation has been improved, there is still a problem with low system gain leading to relatively modest DQE values, especially at low exposures.
  •  
18.
  • Båth, Magnus, 1974, et al. (författare)
  • Investigation of image components affecting the detection of lung nodules in digital chest radiography
  • 2005
  • Ingår i: Progress in Biomedical Optics and Imaging - Proceedings of SPIE. - : SPIE. - 1605-7422. ; 5749, s. 231-242
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • The aim of this work was to investigate and quantify the effects of system noise, nodule location, anatomical noise and anatomical background on the detection of lung nodules in different regions of the chest x-ray. Simulated lung nodules of diameter 10 mm but with varying detail contrast were randomly positioned in four different kinds of images: 1) clinical images collected with a 200 speed CR system, 2) images containing only system noise (including quantum noise) at the same level as the clinical images, 3) clinical images with removed anatomical noise, 4) artificial images with similar power spectrum as the clinical images but random phase spectrum. An ROC study was conducted with 5 observers. The detail contrast needed to obtain an Az of 0.80, C0.8, was used as measure of detectability. Five different regions of the chest x-ray were investigated separately. The C0.8 of the system noise images ranged from only 2% (the hilar regions) to 20% (the lateral pulmonary regions) of those of the clinical images. Compared with the original clinical images, the C0.8 was 16% lower for the de-noised clinical images and 71% higher for the random phase images, respectively, averaged over all five regions. In conclusion, regarding the detection of lung nodules with a diameter of 10 mm, the system noise is of minor importance at clinically relevant dose levels. The removal of anatomical noise and other noise sources uncorrelated from image to image leads to somewhat better detection, but the major component disturbing the detection is the overlapping of recognizable structures, which are, however, the main aspect of an x-ray image.
  •  
19.
  • Båth, Magnus, 1974, et al. (författare)
  • Investigation of parameters concerning the modulation transfer function in digital radiography
  • 2001
  • Ingår i: Proceedings of SPIE - The International Society for Optical Engineering. - : SPIE. - 0277-786X. ; 4320, s. 350-361
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • The effects of the design of a radiographic system on the modulation transfer function (MTF) are studied with a specially developed computer program. The program simulates a digital radiographic system by using three parameters: sampling distance, sampling aperture, and the spread of the signal in the detector due to the interaction processes of the incoming photons. The signal spread is approximated by Gaussian distributions. The influence of the three parameters is studied on the presampling MTF and on the two extreme cases of the digital MTF: The maximum MTF and the minimum MTF. From theoretical data on the interaction processes, the resolution properties of an amorphous selenium flat-panel detector are simulated. The program is also used to simulate a measurement of the presampling MTF with the slit method, and the effect of the slit width on the measured presampling MTF is examined.
  •  
20.
  • Båth, Magnus, 1974, et al. (författare)
  • Method for determining the two-dimensional presampling modulation transfer function in digital radiography
  • 2001
  • Ingår i: Proceedings of SPIE - The International Society for Optical Engineering. - : SPIE. - 0277-786X. ; 4320, s. 268-279
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • In digital radiography, radial asymmetry may be present. The use of a one-dimensional representation of the resolution properties can therefore be questioned. Although measurements are often done in two orthogonal directions, there may be a need for a more detailed description. A method of measuring the two-dimensional presampling modulation transfer function (MTF) has therefore been developed. A finely sampled "disk spread function" is obtained by imaging an aperture mask, consisting of N2 circular holes arranged in an N×N manner in an opaque material, in such a way that each hole is positioned at a different phase relative to the sampling coordinates of the detector system. This spread function is resampled, extrapolated, Fourier transformed, and finally corrected for the finite hole size in order to obtain the presampling MTF. The method was tested on a computed radiography (CR) system through measurements with a prototype mask, consisting of 100 holes of radius 0.2 mm drilled in a lead alloy. The results were compared with measurements using the slit method, and were found to be consistent. Problems associated with the method, e.g. errors due to incorrect alignment of the holes in the aperture mask with the beam, and limitations due to the finite hole size, are discussed.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 11-20 av 148
Typ av publikation
Typ av innehåll
refereegranskat (127)
övrigt vetenskapligt/konstnärligt (21)
Författare/redaktör
Månsson, Lars Gunnar ... (62)
Johnsson, Åse (Allan ... (36)
Svalkvist, Angelica (34)
Vikgren, Jenny, 1957 (30)
Håkansson, Markus (23)
visa fler...
Kheddache, Susanne, ... (21)
Tingberg, Anders (20)
Mattsson, Sören (16)
Sund, Patrik (15)
Söderman, Christina (13)
Flinck, Agneta, 1953 (13)
Ruschin, Mark (12)
Rossi-Norrlund, Raun ... (11)
Hansson, Jonny (11)
Molnar, David (10)
Boijsen, Marianne, 1 ... (10)
Ivarsson, Jonas, 197 ... (9)
Hemdal, Bengt (9)
Thilander-Klang, Ann ... (9)
Zachrisson, Sara (9)
Grahn, Anna (9)
Rystedt, Hans, 1951 (8)
Lundh, Charlotta, 19 ... (8)
Andersson, Ingvar (8)
Börjesson, Sara (8)
Asplund, Sara, 1976 (7)
Fisichella, Valeria ... (7)
Medin, Joakim (5)
Timberg, Pontus (5)
Bernhardt, Peter, 19 ... (5)
Börjesson, S (4)
Besjakov, Jack (4)
Almén, Anja, 1964 (4)
Robinson, J. (3)
Svensson, S (3)
Alm Carlsson, Gudrun ... (3)
Sandborg, Michael, 1 ... (3)
Hellström, Mikael, 1 ... (3)
Almén, Anja (3)
Sandblom, Viktor, 19 ... (3)
Mattsson, S. (3)
Svensson, Johanna (3)
Svahn, Tony (3)
Söderberg, Jonas (3)
Thompson, N. (3)
Cederblad, Åke, 1947 (3)
Ullman, Gustaf (3)
Svensson, Sune (3)
Starck, Sven-Åke (3)
visa färre...
Lärosäte
Göteborgs universitet (148)
Lunds universitet (23)
Linköpings universitet (7)
Uppsala universitet (4)
Jönköping University (3)
Örebro universitet (2)
visa fler...
Karolinska Institutet (2)
Chalmers tekniska högskola (1)
RISE (1)
visa färre...
Språk
Engelska (148)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (146)
Teknik (9)
Naturvetenskap (5)
Samhällsvetenskap (5)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy