SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "db:Swepub ;pers:(Persson Anders);mspu:(article)"

Sökning: db:Swepub > Persson Anders > Tidskriftsartikel

  • Resultat 21-30 av 508
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
21.
  • Berglund, Martin, 1985-, et al. (författare)
  • Manufacturing Miniature Langmuir probes by Fusing Platinum Bond Wires
  • 2015
  • Ingår i: Journal of Micromechanics and Microengineering. - Bristol : Institute of Physics Publishing (IOPP). - 0960-1317 .- 1361-6439. ; 25:10
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper reports on a novel method for manufacturing microscopic Langmuir probes with spherical tips from platinum bond wires by fusing for plasma characterization in microplasma sources. Here, the resulting endpoints, formed by droplets on the ends of a fused wire, are intended to act as spherical Langmuir probes. For studying the fusing behavior, bond wires were wedge bonded over a 2 mm wide slit, to emulate the final application, and fused with different voltages and currents. For electrical isolation, a set of wires were coated with a 4 μm thick layer of Parylene before they were fused. After fusing, the gap size, as well as the shape and area of the ends of the remaining stubs were measured. The yield of the process was also investigated, and the fusing event was studied using a high-speed camera for analyzing its dynamics. Four characteristic tip shapes were observed: spherical, folded, serpentine shaped and semi-spherical. The stub length leveled out at  ~400 μm as the fusing power increased. The fusing of the coated wires required a higher power to yield a spherical shape. Finally, a Parylene coated bond wire was integrated into a stripline split-ring resonator (SSRR) microplasma source, and was fused to form two Langmuir probes with spherical endpoints. These probes were used for measuring the I–V characteristics of a plasma generated by the SSRR. In a voltage range between  −60 V and 60 V, the fused stubs exhibited the expected behavior of spherical Langmuir probes, and will be considered for further integration.
  •  
22.
  • Berglund, Martin, 1985-, et al. (författare)
  • Microplasma source for optogalvanic spectroscopy of nanogram samples
  • 2013
  • Ingår i: Journal of Applied Physics. - : American Institute of Physics (AIP). - 0021-8979 .- 1089-7550. ; 114:3, s. 033302-
  • Tidskriftsartikel (refereegranskat)abstract
    • The demand for analysis of smaller samples in isotopic ratio measurements of rare isotopes is continuously rising with the development of new applications, particularly in biomedicine. Interesting in this aspect are methods based on optogalvanic spectroscopy, which have been reported to facilitate both 13C-to-12C and 14C-to-12C ratio measurements with high sensitivity. These methods also facilitate analysis of very small samples, down to the microgram range, which makes them very competitive to other technologies, e.g., accelerator mass spectroscopy. However, there exists a demand for moving beyond the microgram range, especially from regenerative medicine, where samples consist of, e.g., DNA, and, hence, the total sample amount is extremely small. Making optogalvanic spectroscopy of carbon isotopes applicable to such small samples, requires miniaturization of the key component of the system, namely the plasma source, in which the sample is ionized before analysis. In this paper, a novel design of such a microplasma source based on a stripline split-ring resonator is presented and evaluated in a basic optogalvanic spectrometer. The investigations focus on the capability of the plasma source to measure the optogalvanic signal in general, and the effect of different system and device specific parameters on the amplitude and stability of the optogalvanic signal in particular. Different sources of noise and instabilities are identified, and methods of mitigating these issues are discussed. Finally, the ability of the cell to handle analysis of samples down to the nanogram range is investigated, pinpointing the great prospects of stripline split-ring resonators in optogalvanic spectroscopy.
  •  
23.
  • Berglund, Martin, et al. (författare)
  • Operation characteristics and optical emission distribution of a miniaturized silicon through-substrate split-ring resonator microplasma source
  • 2014
  • Ingår i: Journal of microelectromechanical systems. - 1057-7157 .- 1941-0158. ; 23:6, s. 1340-1345
  • Tidskriftsartikel (refereegranskat)abstract
    • There are many new microplasma sources being developed for a wide variety of applications, each with different properties tailored to its specific use. Microplasma sources enable portable instruments for, e.g., chemical analysis, sterilization, or activation of substances. A novel microplasma source, based on a microstrip split-ring resonator design with electrodes integrated in its silicon substrate, was designed, manufactured, and evaluated. This device has a plasma discharge gap with a controlled volume and geometry, and offers straightforward integration with other microelectromechancial systems (MEMS) components, e.g., microfluidics. The realized device was resonant at around 2.9 GHz with a quality factor of 18.7. Two different operational modes were observed with the plasma at high pressure being confined in the gap between the electrodes, whereas the plasma at low pressures appeared between the ends of the electrodes on the backside. Measurement of the angular distribution of light emitted from the device with through-substrate electrodes showed narrow emission lobes compared with a reference plasma source with on-substrate electrodes.
  •  
24.
  • Bergman, Eva, et al. (författare)
  • Synthesis of theoretical and empirical experineces from nutrient and cyprinid reductions in Lake Ringsjön
  • 1999
  • Ingår i: Hydrobiologia. - 0018-8158. ; 404, s. 145-156
  • Tidskriftsartikel (refereegranskat)abstract
    • The reduction in external phosphorus load to Lake Ringsjön during the 1980s, did not result in improved water transparency during the following ten-year period. Furthermore, a fish-kill in the Eastern Basin of the lake, in addition to a cyprinid reduction programme (biomanipulation; 1988–1992), in contrast to theory, did not lead to any increase in zooplankton biomass or size. This absence of response in the pelagic food chain may have been attributed to the increase in abundance of YOY (0+) fish, following the fish reduction programme. Despite the lack of effect on zooplankton, there was a decrease in phytoplankton biomass, a change in species composition and an increase in water transparency following biomanipulation. In 1989, one year after the fish-kill in Eastern Basin, the Secchi depth (summer mean) increased from 60 cm to 110 cm. In the following years, water transparency increased further, despite an increase in phosphorus loading. An unexpected effect of the biomanipulation was an increase in benthic invertebrate and staging waterfowl abundances, which occurred 2–4 years after fish reduction. Hence, the response in the benthic community following biomanipulation was considerably stronger than in the pelagic community. A likely explanation is that reduction in abundance of the benthic feeding fish species bream (Abramis brama), strongly affected the benthic invertebrate fauna. In this paper, we present what we believe happened in Lake Ringsjön, and which processes are likely to have been important at various stages of the restoration process.
  •  
25.
  •  
26.
  • Bergstrom, H, et al. (författare)
  • Two different types of hollow-cathode discharges used for high resolution laser spectroscopy on copper
  • 1989
  • Ingår i: Zeitschrift für Physik D Atoms, Molecules and Clusters. - 0178-7683. ; 13:3, s. 203-206
  • Tidskriftsartikel (refereegranskat)abstract
    • Two different techniques, Doppler-free saturation spectroscopy on a hollow-cathode discharge and fluorescence spectroscopy on a collimated atomic beam produced from a hollow-cathode discharge, have been used for high-resolution laser-spectroscopy measurements on the 3d10 4p and 5p states in neutral Copper. The relative merits of the two techniques are discussed.
  •  
27.
  • Bergström, Göran, 1964, et al. (författare)
  • Body weight at age 20 and in midlife is more important than weight gain for coronary atherosclerosis: Results from SCAPIS.
  • 2023
  • Ingår i: Atherosclerosis. - : Elsevier BV. - 1879-1484 .- 0021-9150. ; 373, s. 46-54
  • Tidskriftsartikel (refereegranskat)abstract
    • Elevated body weight in adolescence is associated with early cardiovascular disease, but whether this association is traceable to weight in early adulthood, weight in midlife or to weight gain is not known. The aim of this study is to assess the risk of midlife coronary atherosclerosis being associated with body weight at age 20, body weight in midlife and body weight change.We used data from 25,181 participants with no previous myocardial infarction or cardiac procedure in the Swedish CArdioPulmonary bioImage Study (SCAPIS, mean age 57 years, 51% women). Data on coronary atherosclerosis, self-reported body weight at age 20 and measured midlife weight were recorded together with potential confounders and mediators. Coronary atherosclerosis was assessed using coronary computed tomography angiography (CCTA) and expressed as segment involvement score (SIS).The probability of having coronary atherosclerosis was markedly higher with increasing weight at age 20 and with mid-life weight (p < 0.001 for both sexes). However, weight increase from age 20 until mid-life was only modestly associated with coronary atherosclerosis. The association between weight gain and coronary atherosclerosis was mainly seen in men. However, no significant sex difference could be detected when adjusting for the 10-year delay in disease development in women.Similar in men and women, weight at age 20 and weight in midlife are strongly related to coronary atherosclerosis while weight increase from age 20 until midlife is only modestly related to coronary atherosclerosis.
  •  
28.
  • Bergström, Göran, 1964, et al. (författare)
  • Prevalence of Subclinical Coronary Artery Atherosclerosis in the General Population
  • 2021
  • Ingår i: Circulation. - Philadelphia : American Heart Association. - 0009-7322 .- 1524-4539. ; 144:12, s. 916-929
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Early detection of coronary atherosclerosis using coronary computed tomography angiography (CCTA), in addition to coronary artery calcification (CAC) scoring, may help inform prevention strategies. We used CCTA to determine the prevalence, severity, and characteristics of coronary atherosclerosis and its association with CAC scores in a general population.Methods: We recruited 30 154 randomly invited individuals age 50 to 64 years to SCAPIS (the Swedish Cardiopulmonary Bioimage Study). The study includes individuals without known coronary heart disease (ie, no previous myocardial infarctions or cardiac procedures) and with high-quality results from CCTA and CAC imaging performed using dedicated dual-source CT scanners. Noncontrast images were scored for CAC. CCTA images were visually read and scored for coronary atherosclerosis per segment (defined as no atherosclerosis, 1% to 49% stenosis, or ≥50% stenosis). External validity of prevalence estimates was evaluated using inverse probability for participation weighting and Swedish register data.Results: In total, 25 182 individuals without known coronary heart disease were included (50.6% women). Any CCTA-detected atherosclerosis was found in 42.1%; any significant stenosis (≥50%) in 5.2%; left main, proximal left anterior descending artery, or 3-vessel disease in 1.9%; and any noncalcified plaques in 8.3% of this population. Onset of atherosclerosis was delayed on average by 10 years in women. Atherosclerosis was more prevalent in older individuals and predominantly found in the proximal left anterior descending artery. Prevalence of CCTA-detected atherosclerosis increased with increasing CAC scores. Among those with a CAC score >400, all had atherosclerosis and 45.7% had significant stenosis. In those with 0 CAC, 5.5% had atherosclerosis and 0.4% had significant stenosis. In participants with 0 CAC and intermediate 10-year risk of atherosclerotic cardiovascular disease according to the pooled cohort equation, 9.2% had CCTA-verified atherosclerosis. Prevalence estimates had excellent external validity and changed marginally when adjusted to the age-matched Swedish background population.Conclusions: Using CCTA in a large, random sample of the general population without established disease, we showed that silent coronary atherosclerosis is common in this population. High CAC scores convey a significant probability of substantial stenosis, and 0 CAC does not exclude atherosclerosis, particularly in those at higher baseline risk.
  •  
29.
  • Bergström, Göran, et al. (författare)
  • Prevalence of Subclinical Coronary Artery Atherosclerosis in the General Population
  • 2021
  • Ingår i: Circulation. - : Wolters Kluwer. - 0009-7322 .- 1524-4539. ; 144:12, s. 916-929
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Early detection of coronary atherosclerosis using coronary computed tomography angiography (CCTA), in addition to coronary artery calcification (CAC) scoring, may help inform prevention strategies. We used CCTA to determine the prevalence, severity, and characteristics of coronary atherosclerosis and its association with CAC scores in a general population.Methods: We recruited 30 154 randomly invited individuals age 50 to 64 years to SCAPIS (the Swedish Cardiopulmonary Bioimage Study). The study includes individuals without known coronary heart disease (ie, no previous myocardial infarctions or cardiac procedures) and with high-quality results from CCTA and CAC imaging performed using dedicated dual-source CT scanners. Noncontrast images were scored for CAC. CCTA images were visually read and scored for coronary atherosclerosis per segment (defined as no atherosclerosis, 1% to 49% stenosis, or ≥50% stenosis). External validity of prevalence estimates was evaluated using inverse probability for participation weighting and Swedish register data.Results: In total, 25 182 individuals without known coronary heart disease were included (50.6% women). Any CCTA-detected atherosclerosis was found in 42.1%; any significant stenosis (≥50%) in 5.2%; left main, proximal left anterior descending artery, or 3-vessel disease in 1.9%; and any noncalcified plaques in 8.3% of this population. Onset of atherosclerosis was delayed on average by 10 years in women. Atherosclerosis was more prevalent in older individuals and predominantly found in the proximal left anterior descending artery. Prevalence of CCTA-detected atherosclerosis increased with increasing CAC scores. Among those with a CAC score >400, all had atherosclerosis and 45.7% had significant stenosis. In those with 0 CAC, 5.5% had atherosclerosis and 0.4% had significant stenosis. In participants with 0 CAC and intermediate 10-year risk of atherosclerotic cardiovascular disease according to the pooled cohort equation, 9.2% had CCTA-verified atherosclerosis. Prevalence estimates had excellent external validity and changed marginally when adjusted to the age-matched Swedish background population.Conclusions: Using CCTA in a large, random sample of the general population without established disease, we showed that silent coronary atherosclerosis is common in this population. High CAC scores convey a significant probability of substantial stenosis, and 0 CAC does not exclude atherosclerosis, particularly in those at higher baseline risk.
  •  
30.
  • Björklund Svensson, Jonas, et al. (författare)
  • Low-divergence femtosecond X-ray pulses from a passive plasma lens
  • 2021
  • Ingår i: Nature Physics. - : Springer Science and Business Media LLC. - 1745-2481 .- 1745-2473. ; 17:5, s. 639-645
  • Tidskriftsartikel (refereegranskat)abstract
    • Electron and X-ray beams originating from compact laser-wakefield accelerators have very small source sizes that are typically on the micrometre scale. Therefore, the beam divergences are relatively high, which makes it difficult to preserve their high quality during transport to applications. To improve on this, tremendous efforts have been invested in controlling the divergence of the electron beams, but no mechanism for generating collimated X-ray beams has yet been demonstrated experimentally. Here we propose and realize a scheme where electron bunches undergoing focusing in a dense, passive plasma lens can emit X-ray pulses with divergences approaching the incoherent limit. Compared with conventional betatron emission, the divergence of this so-called plasma lens radiation is reduced by more than an order of magnitude in solid angle, while maintaining a similar number of emitted photons per electron. This X-ray source offers the possibility of producing brilliant and collimated few-femtosecond X-ray pulses for ultra-fast science, in particular for studies based on X-ray diffraction and absorption spectroscopy. X-ray pulses with low divergences are produced in a laser-wakefield accelerator by focusing electron bunches in a dense passive plasma lens.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 21-30 av 508
Typ av publikation
Typ av innehåll
refereegranskat (386)
populärvet., debatt m.m. (84)
övrigt vetenskapligt/konstnärligt (38)
Författare/redaktör
Wahlström, Claes-Gör ... (54)
Lundh, Olle (30)
Svanberg, Sune (23)
Engström, Gunnar (17)
Lindau, Filip (15)
visa fler...
Brönmark, Christer (14)
Genoud, Guillaume (14)
Engvall, Jan (13)
Burza, Matthias (13)
Persson, Margaretha (12)
Hansson, Lars-Anders (12)
L'Huillier, Anne (12)
Nilsson, Anders (11)
Smedby, Örjan (10)
Eriksson, Peter S, 1 ... (10)
de Geer, Jakob (10)
Lind, Lars (9)
Cros, B (9)
Svensson, Kristoffer (9)
Lundström, Claes, 19 ... (9)
Jernberg, Tomas (8)
Söderberg, Stefan (8)
Hansson, Martin (8)
Ebbers, Tino (8)
Cassou, K. (8)
Bergström, Göran, 19 ... (7)
Hagström, Emil (7)
Larsson, Jörgen (7)
Warntjes, Marcel Jan ... (7)
Carlhäll, Carljohan (7)
Hallgren, Per (7)
Östgren, Carl Johan (7)
Smedby, Örjan, 1956- (6)
Rosengren, Annika, 1 ... (6)
Andersson, Gunnar (6)
Salehpour, Mehran (6)
Thorlin, Thorleif (6)
McKenna, P. (6)
Ynnerman, Anders (6)
Markstad, Hanna (6)
Johnson, Linda S.B. (6)
Schoepf, U. Joseph (6)
Coenen, Adriaan (6)
Yang, Dong Hyun (6)
Kepka, Cezary (6)
Nieman, Koen (6)
Tesche, Christian (6)
Najmudin, Z. (6)
Nguyen, Hugo (6)
visa färre...
Lärosäte
Lunds universitet (255)
Linköpings universitet (129)
Uppsala universitet (67)
Göteborgs universitet (33)
Karolinska Institutet (26)
Linnéuniversitetet (23)
visa fler...
Umeå universitet (20)
Högskolan Dalarna (16)
Kungliga Tekniska Högskolan (11)
Karlstads universitet (10)
Chalmers tekniska högskola (7)
Luleå tekniska universitet (6)
Högskolan i Halmstad (6)
Högskolan i Borås (6)
Sveriges Lantbruksuniversitet (5)
Högskolan Väst (3)
Örebro universitet (3)
Försvarshögskolan (3)
Stockholms universitet (2)
Malmö universitet (2)
Gymnastik- och idrottshögskolan (2)
Mittuniversitetet (1)
RISE (1)
visa färre...
Språk
Engelska (403)
Svenska (100)
Tyska (2)
Odefinierat språk (2)
Franska (1)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (174)
Samhällsvetenskap (159)
Medicin och hälsovetenskap (97)
Teknik (61)
Humaniora (14)
Lantbruksvetenskap (4)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy