SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "db:Swepub ;pers:(Persson Anders);mspu:(article)"

Sökning: db:Swepub > Persson Anders > Tidskriftsartikel

  • Resultat 61-70 av 506
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
61.
  •  
62.
  • Dahlström, Nils, 1969-, et al. (författare)
  • Contrast-enhanced magnetic resonance cholangiography with Gd-BOPTA and Gd-EOB-DTPA in healthy subjects
  • 2007
  • Ingår i: Acta Radiologica. - : Informa Healthcare. - 0284-1851 .- 1600-0455. ; 48:4, s. 362-368
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To evaluate the biliary enhancement dynamics of the two gadolinium chelates Gd-BOPTA (MultiHance) and Gd-EOB-DTPA (Primovist) in normal healthy subjects. MATERIAL AND METHODS: Ten healthy volunteers were evaluated with both agents by magnetic resonance (MR) imaging at 1.5T using a breath-hold gradient-echo T1-weighted VIBE sequence. The relative signal intensity (SI) differences between the common hepatic duct (CHD) and liver parenchyma were measured before and 10, 20, 30, 40, 130, 240, and 300 min after contrast medium injection. RESULTS: Biliary enhancement was obvious 10 min post-injection for Gd-EOB-DTPA and was noted at 20 min for Gd-BOPTA. At 40 min delay, Gd-BOPTA reached its peak biliary enhancement, but at neither 30 nor 40 min delay was there any significant difference compared with that of Gd-EOB-DTPA. At later delays, the contrast between CHD and liver continued to increase for Gd-EOB-DTPA, whereas it decreased for Gd-BOPTA. CONCLUSION: The earlier onset and longer duration of a high contrast between CHD and liver for Gd-EOB-DTPA facilitates examination of hepatobiliary excretion. Therefore, Gd-EOB-DTPA may provide adequate hepatobiliary imaging within a shorter time span than Gd-BOPTA and facilitate scheduling at the MR unit. Further studies in patients are required to compare the imaging advantages of Gd-EOB-DTPA and Gd-BOPTA in clinical practice.
  •  
63.
  • Dalui, Malay, et al. (författare)
  • Influence of micromachined targets on laser accelerated proton beam profiles
  • 2018
  • Ingår i: Plasma Physics and Controlled Fusion. - : IOP Publishing. - 0741-3335 .- 1361-6587. ; 60:3
  • Tidskriftsartikel (refereegranskat)abstract
    • High intensity laser-driven proton acceleration from micromachined targets is studied experimentally in the target-normal-sheath-acceleration regime. Conical pits are created on the front surface of flat aluminium foils of initial thickness 12.5 and 3 μm using series of low energy pulses (0.5-2.5 μJ). Proton acceleration from such micromachined targets is compared with flat foils of equivalent thickness at a laser intensity of 7 ×1019 W cm-2. The maximum proton energy obtained from targets machined from 12.5 μm thick foils is found to be slightly lower than that of flat foils of equivalent remaining thickness, and the angular divergence of the proton beam is observed to increase as the depth of the pit approaches the foil thickness. Targets machined from 3 μm thick foils, on the other hand, show evidence of increasing the maximum proton energy when the depths of the structures are small. Furthermore, shallow pits on 3 μm thick foils are found to be efficient in reducing the proton beam divergence by a factor of up to three compared to that obtained from flat foils, while maintaining the maximum proton energy.
  •  
64.
  • Darras, Kathryn E., et al. (författare)
  • Is there a superior simulator for human anatomy education? How virtual dissection can overcome the anatomic and pedagogic limitations of cadaveric dissection
  • 2018
  • Ingår i: Medical teacher. - : TAYLOR & FRANCIS LTD. - 0142-159X .- 1466-187X. ; 40:7, s. 752-753
  • Tidskriftsartikel (refereegranskat)abstract
    • Educators must select the best tools to teach anatomy to future physicians and traditionally, cadavers have always been considered the "gold standard" simulator for living anatomy. However, new advances in technology and radiology have created new teaching tools, such as virtual dissection, which provide students with new learning opportunities. Virtual dissection is a novel way of studying human anatomy through patient computed tomography (CT) scans. Through touchscreen technology, students can work together in groups to "virtually dissect" the CT scans to better understand complex anatomic relationships. This article presents the anatomic and pedagogic limitations of cadaveric dissection and explains what virtual dissection is and how this new technology may be used to overcome these limitations.
  •  
65.
  • de Geer, Jakob, et al. (författare)
  • Effect of Tube Voltage on Diagnostic Performance of Fractional Flow Reserve Derived From Coronary CT Angiography With Machine Learning: Results From the MACHINE Registry
  • 2019
  • Ingår i: American Journal of Roentgenology. - : AMER ROENTGEN RAY SOC. - 0361-803X .- 1546-3141. ; 213:2, s. 325-331
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE. Coronary CT angiography (CCTA)-based methods allow noninvasive estimation of fractional flow reserve (cFFR), recently through use of a machine learning (ML) algorithm (cFFR(ML)). However, attenuation values vary according to the tube voltage used, and it has not been shown whether this significantly affects the diagnostic performance of cFFR and cFFR(ML). Therefore, the purpose of this study is to retrospectively evaluate the effect of tube voltage on the diagnostic performance of cFFR(ML). MATERIALS AND METHODS. A total of 525 coronary vessels in 351 patients identified in the MACHINE consortium registry were evaluated in terms of invasively measured FFR and cFFR(ML). CCTA examinations were performed with a tube voltage of 80, 100, or 120 kVp. For each tube voltage value, correlation (assessed by Spearman rank correlation coefficient), agreement (evaluated by intraclass correlation coefficient and Bland-Altman plot analysis), and diagnostic performance (based on ROC AUC value, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy) of the cFFR(ML) in terms of detection of significant stenosis were calculated. RESULTS. For tube voltages of 80, 100, and 120 kVp, the Spearman correlation coefficient for cFFR(ML) in relation to the invasively measured FFR value was rho = 0.684, rho = 0.622, and rho = 0.669, respectively (p amp;lt; 0.001 for all). The corresponding intraclass correlation coefficient was 0.78, 0.76, and 0.77, respectively (p amp;lt; 0.001 for all). Sensitivity was 100.0%, 73.5%, and 85.0%, and specificity was 76.2%, 79.0%, and 72.8% for tube voltages of 80, 100, and 120 kVp, respectively. The ROC AUC value was 0.90, 0.82, and 0.80 for 80, 100, and 120 kVp, respectively (p amp;lt; 0.001 for all). CONCLUSION. CCTA-derived cFFR(ML) is a robust method, and its performance does not vary significantly between examinations performed using tube voltages of 100 kVp and 120 kVp. However, because of rapid advancements in CT and postprocessing technology, further research is needed.
  •  
66.
  • De Geer, Jakob, et al. (författare)
  • Large variation in blood flow between left ventricular segments, as detected by adenosine stress dynamic CT perfusion.
  • 2015
  • Ingår i: Clinical Physiology and Functional Imaging. - : Wiley. - 1475-0961 .- 1475-097X. ; 35:4, s. 291-300
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Dynamic cardiac CT perfusion (CTP) is based on repeated imaging during the first-pass contrast agent inflow. It is a relatively new method that still needs validation.PURPOSE: To evaluate the variation in adenosine stress dynamic CTP blood flow as compared to (99m) Tc SPECT. Secondarily, to compare manual and automatic segmentation.METHODS: Seventeen patients with manifest coronary artery disease were included. Nine were excluded from evaluation for various reasons. All patients were examined with dynamic stress CTP and stress/rest SPECT. CTP blood flow was compared with SPECT on a per segment basis. Results for manual and automated AHA segmentation were compared.RESULTS: CTP showed a positive correlation with SPECT, with correlation coefficients of 0·38 and 0·41 for manual and automatic segmentation, respectively (P<0·0001). There was no significant difference between the correlation coefficients of the manual and automated segmentation procedures (P = 0·75). The average per individual global CTP blood flow value for normal segments varied by a factor of 1·9 (manual and automatic segmentation). For the whole patient group, the CTP blood flow value in normal segments varied by a factor of 2·9/2·7 (manual/automatic segmentation). Within each patient, the average per segment blood flow in normal segments varied by a factor of 1·3-2·0/1·2-2·1 (manual/automatic segmentation).CONCLUSION: A positive but rather weak correlation was found between CTP and (99m) Tc SPECT. Large variations in CTP blood flow suggest that a cut-off value for stress myocardial blood flow is inadequate to detect ischaemic segments. Dynamic CTP is hampered by a limited coverage.
  •  
67.
  • De Geer, Jakob, et al. (författare)
  • Software-based on-site estimation of fractional flow reserve using standard coronary CT angiography data.
  • 2016
  • Ingår i: Acta Radiologica. - : Sage Publications. - 0284-1851 .- 1600-0455. ; 57:10, s. 1186-1192
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: The significance of a coronary stenosis can be determined by measuring the fractional flow reserve (FFR) during invasive coronary angiography. Recently, methods have been developed which claim to be able to estimate FFR using image data from standard coronary computed tomography angiography (CCTA) exams.PURPOSE: To evaluate the accuracy of non-invasively computed fractional flow reserve (cFFR) from CCTA.MATERIAL AND METHODS: A total of 23 vessels in 21 patients who had undergone both CCTA and invasive angiography with FFR measurement were evaluated using a cFFR software prototype. The cFFR results were compared to the invasively obtained FFR values. Correlation was calculated using Spearman's rank correlation, and agreement using intraclass correlation coefficient (ICC). Sensitivity, specificity, accuracy, negative predictive value, and positive predictive value for significant stenosis (defined as both FFR ≤0.80 and FFR ≤0.75) were calculated.RESULTS: The mean cFFR value for the whole group was 0.81 and the corresponding mean invFFR value was 0.84. The cFFR sensitivity for significant stenosis (FFR ≤0.80/0.75) on a per-lesion basis was 0.83/0.80, specificity was 0.76/0.89, and accuracy 0.78/0.87. The positive predictive value was 0.56/0.67 and the negative predictive value was 0.93/0.94. The Spearman rank correlation coefficient was ρ = 0.77 (P < 0.001) and ICC = 0.73 (P < 0.001).CONCLUSION: This particular CCTA-based cFFR software prototype allows for a rapid, non-invasive on-site evaluation of cFFR. The results are encouraging and cFFR may in the future be of help in the triage to invasive coronary angiography.
  •  
68.
  • de Geer, Jakob, et al. (författare)
  • The efficacy of 2D, non-linear noise reduction filtering in cardiac imaging: a pilot study
  • 2011
  • Ingår i: Acta Radiologica. - : Informa Healthcare / Wiley-Blackwell / Royal Society of Medicine Press. - 0284-1851 .- 1600-0455. ; 52:7, s. 716-722
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Computed tomography (CT) is becoming increasingly popular as a non-invasive method for visualizing the coronary arteries but patient radiation doses are still an issue. Postprocessing filters such as 2D adaptive non-linear filters might help to reduce the dose without loss of image quality. less thanbrgreater than less thanbrgreater thanPurpose: To investigate whether the use of a 2D, non-linear adaptive noise reduction filter can improve image quality in cardiac computed tomography angiography (CCTA). less thanbrgreater than less thanbrgreater thanMaterial and Methods: CCTA examinations were performed in 36 clinical patients on a dual source CT using two patient dose levels: maximum dose during diastole and reduced dose (20% of maximum dose) during systole. One full-dose and one reduced-dose image were selected from each of the examinations. The reduced-dose image was duplicated and one copy postprocessed using a 2D non-linear adaptive noise reduction filter, resulting in three images per patient. Image quality was assessed using visual grading with three criteria from the European guidelines for assessment of image quality and two additional criteria regarding the left main artery and the overall image quality. Also, the HU value and its standard deviation were measured in the ascending and descending aorta. Data were analyzed using Visual Grading Regression and paired t-test. less thanbrgreater than less thanbrgreater thanResult: For all five criteria, there was a significant (P andlt; 0.01 or better) improvement in perceived image quality when comparing postprocessed low-dose images with low-dose images without noise reduction. Comparing full dose images with postprocessed low-dose images resulted in a considerably larger, significant (P andlt; 0.001) difference. Also, there was a significant reduction of the standard deviation of the HU values in the ascending and descending aorta when comparing postprocessed low-dose images with low-dose images without postprocessing. less thanbrgreater than less thanbrgreater thanConclusion: Even with an 80% dose reduction, there was a significant improvement in the perceived image quality when using a 2D noise-reduction filter, though not approaching the quality of full-dose images. This indicates that cardiac CT examinations could benefit from noise-reducing postprocessing with 2D non-linear adaptive filters.
  •  
69.
  • Desforges, F. G., et al. (författare)
  • Reproducibility of electron beams from laser wakefield acceleration in capillary tubes
  • 2014
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - : Elsevier BV. - 0167-5087 .- 0168-9002. ; 740, s. 54-59
  • Tidskriftsartikel (refereegranskat)abstract
    • The stability of accelerated electron beams produced by self injection of plasma electrons into the wakefield driven by a laser pulse guided inside capillary tubes is analyzed statistically in relation to laser and plasma parameters, and compared to results obtained in a gas jet. The analysis shows that reproducible electron beams are achieved with a charge of 66 pC +/- 11%, a FWHM beam divergence of 9 mrad +/- 14%, a maximum energy of 120 MeV +/- 10% and pointing fluctuations of 2.3 mrad using 10 mm long, 178 mu m diameter capillary tubes at an electron density of (10.0 +/- 1.5) x 10(18) cm(-3). Active stabilization of the laser pointing was used and laser parameters were recorded on each shot. Although the shot-to-shot laser energy fluctuations can account for a fraction of the electrons fluctuations, gas density fluctuations are suspected to be a more important source of instability. (C) 2013 Elsevier B.V. All rights reserved.
  •  
70.
  • DeSouza, Nandita M., et al. (författare)
  • Standardised lesion segmentation for imaging biomarker quantitation : a consensus recommendation from ESR and EORTC
  • 2022
  • Ingår i: Insights into Imaging. - : Springer. - 1869-4101. ; 13:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Lesion/tissue segmentation on digital medical images enables biomarker extraction, image-guided therapy delivery, treatment response measurement, and training/validation for developing artificial intelligence algorithms and workflows. To ensure data reproducibility, criteria for standardised segmentation are critical but currently unavailable. Methods A modified Delphi process initiated by the European Imaging Biomarker Alliance (EIBALL) of the European Society of Radiology (ESR) and the European Organisation for Research and Treatment of Cancer (EORTC) Imaging Group was undertaken. Three multidisciplinary task forces addressed modality and image acquisition, segmentation methodology itself, and standards and logistics. Devised survey questions were fed via a facilitator to expert participants. The 58 respondents to Round 1 were invited to participate in Rounds 2-4. Subsequent rounds were informed by responses of previous rounds. Results/conclusions Items with >= 75% consensus are considered a recommendation. These include system performance certification, thresholds for image signal-to-noise, contrast-to-noise and tumour-to-background ratios, spatial resolution, and artefact levels. Direct, iterative, and machine or deep learning reconstruction methods, use of a mixture of CE marked and verified research tools were agreed and use of specified reference standards and validation processes considered essential. Operator training and refreshment were considered mandatory for clinical trials and clinical research. Items with a 60-74% agreement require reporting (site-specific accreditation for clinical research, minimal pixel number within lesion segmented, use of post-reconstruction algorithms, operator training refreshment for clinical practice). Items with <= 60% agreement are outside current recommendations for segmentation (frequency of system performance tests, use of only CE-marked tools, board certification of operators, frequency of operator refresher training). Recommendations by anatomical area are also specified.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 61-70 av 506
Typ av publikation
Typ av innehåll
refereegranskat (384)
populärvet., debatt m.m. (84)
övrigt vetenskapligt/konstnärligt (38)
Författare/redaktör
Wahlström, Claes-Gör ... (54)
Lundh, Olle (30)
Svanberg, Sune (23)
Engström, Gunnar (17)
Lindau, Filip (15)
visa fler...
Brönmark, Christer (14)
Genoud, Guillaume (14)
Engvall, Jan (13)
Burza, Matthias (13)
Persson, Margaretha (12)
Hansson, Lars-Anders (12)
L'Huillier, Anne (12)
Nilsson, Anders (11)
Smedby, Örjan (10)
Eriksson, Peter S, 1 ... (10)
de Geer, Jakob (10)
Lind, Lars (9)
Cros, B (9)
Svensson, Kristoffer (9)
Lundström, Claes, 19 ... (9)
Jernberg, Tomas (8)
Söderberg, Stefan (8)
Hansson, Martin (8)
Cassou, K. (8)
Bergström, Göran, 19 ... (7)
Hagström, Emil (7)
Larsson, Jörgen (7)
Warntjes, Marcel Jan ... (7)
Ebbers, Tino (7)
Hallgren, Per (7)
Östgren, Carl Johan (7)
Smedby, Örjan, 1956- (6)
Rosengren, Annika, 1 ... (6)
Andersson, Gunnar (6)
Carlhäll, Carljohan (6)
Salehpour, Mehran (6)
Thorlin, Thorleif (6)
McKenna, P. (6)
Ynnerman, Anders (6)
Markstad, Hanna (6)
Johnson, Linda S.B. (6)
Schoepf, U. Joseph (6)
Coenen, Adriaan (6)
Yang, Dong Hyun (6)
Kepka, Cezary (6)
Nieman, Koen (6)
Tesche, Christian (6)
Najmudin, Z. (6)
Nguyen, Hugo (6)
visa färre...
Lärosäte
Lunds universitet (255)
Linköpings universitet (128)
Uppsala universitet (66)
Göteborgs universitet (33)
Karolinska Institutet (26)
Linnéuniversitetet (23)
visa fler...
Umeå universitet (20)
Högskolan Dalarna (16)
Kungliga Tekniska Högskolan (11)
Karlstads universitet (10)
Chalmers tekniska högskola (7)
Luleå tekniska universitet (6)
Högskolan i Halmstad (6)
Högskolan i Borås (6)
Sveriges Lantbruksuniversitet (5)
Högskolan Väst (3)
Örebro universitet (3)
Försvarshögskolan (3)
Stockholms universitet (2)
Malmö universitet (2)
Gymnastik- och idrottshögskolan (2)
Mittuniversitetet (1)
RISE (1)
visa färre...
Språk
Engelska (401)
Svenska (100)
Tyska (2)
Odefinierat språk (2)
Franska (1)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (174)
Samhällsvetenskap (159)
Medicin och hälsovetenskap (96)
Teknik (60)
Humaniora (14)
Lantbruksvetenskap (4)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy