SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WAKA:kon ;lar1:(hb);pers:(Lindecrantz Kaj)"

Sökning: WAKA:kon > Högskolan i Borås > Lindecrantz Kaj

  • Resultat 21-30 av 37
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
21.
  • Marquez, Juan Carlos, et al. (författare)
  • Comparison of Dry-textile Electrodes for Electrical Bioimpedance Spectroscopy Measurements.
  • 2010
  • Ingår i: Journal of Physics: Conference Series. - : Institute of Physics Publishing Ltd.. - 1742-6596.
  • Konferensbidrag (refereegranskat)abstract
    • Electrodes have been widely studied for biopotentials recordings, specially for monitoring the cardiac activity. Commercially available applications, such as Adistar T-shirt and Textronics Cardioshirt, have proved a good performance for heart rate monitoring and are available worldwide. Textile technology can also be used for Electrical Bioimpedance Spectroscopy measurements enabling home and personalized health monitoring applications however solid ground research about the measurement performance of the electrodes must be done prior to the development of any textile-enabled EBI application. In this work a comparison of the measurement performance of two different types of dry-textile electrodes and manufacturers has been performed against standardized RedDot 3M Ag/AgCl electrolytic electrodes. 4-Electrode, whole body, Ankle-to-Wrist EBI measurements have been taken with the Impedimed spectrometer SFB7 from healthy subjects in the frequency range of 3kHz to 500kHz. Measurements have been taken with dry electrodes at different times to study the influence of the interaction skin-electrode interface on the EBI measurements. The analysis of the obtained complex EBI spectra shows that the measurements performed with textile electrodes produce constant and reliable EBI spectra. Certain deviation can be observed at higher frequencies and the measurements obtained with Textronics and Ag/AgCl electrodes present a better resemblance. Textile technology, if successfully integrated it, may enable the performance of EBI measurements in new scenarios allowing the rising of novel wearable monitoring applications for home and personal care as well as car safety
  •  
22.
  • Marquez, Juan Carlos, 1976-, et al. (författare)
  • Textile electrode straps for wrist-to-ankle bioimpedance measurements for Body Composition Analysis : Initial validation & experimental results
  • 2010
  • Ingår i: 2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC). - : IEEE Engineering in Medicine and Biology Society. - 9781424441235 ; 2010, s. 6385-8
  • Konferensbidrag (refereegranskat)abstract
    • Electrical Bioimpedance (EBI) is one of the non-invasive monitoring technologies that could benefit from the emerging textile based measurement systems. If reliable and reproducible EBI measurements could be done with textile electrodes, that would facilitate the utilization of EBI-based personalized healthcare monitoring applications. In this work the performance of a custom-made dry-textile electrode prototype is tested. Four-electrodes ankle-to-wrist EBI measurements have been taken on healthy subjects with the Impedimed spectrometer SFB7 in the frequency range 5 kHz to 1 MHz. The EBI spectroscopy measurements taken with dry electrodes were analyzed via the Cole and Body Composition Analysis (BCA) parameters, which were compared with EBI measurements obtained with standard electrolytic electrodes. The analysis of the obtained results indicate that even when dry textile electrodes may be used for EBI spectroscopy measurements, the measurements present remarkable differences that influence in the Cole parameter estimation process and in the final production of the BCA parameters. These initial results indicate that more research work must be done to in order to obtain a textile-based electrode that ensures reliable and reproducible EBI spectroscopy measurements.
  •  
23.
  •  
24.
  • Marquez, Juan Carlos, et al. (författare)
  • Textile electrodes in Electrical Bioimpedance measurements - a comparison with conventional Ag/AgCl electrodes
  • 2009
  • Ingår i: EMBC. - : IEEE. - 9781424432950 ; , s. 4816-4819, s. 4816-4819
  • Konferensbidrag (refereegranskat)abstract
    • Work has been intensified around the integration of textile and measurement technology for physiological measurements in the last years. As a result nowadays it is possible to find available commercial products for cardiovascular personal healthcare monitoring. Most of the efforts have been focused in the acquisition of EKG for cardiovascular monitoring where textile electrodes have shown satisfactory performance. Electrical Bioimpedance is another type of physiological measurement that can be used for personal healthcare monitoring where the integration and the performance of the textile electrodes has not been investigated that thoroughly. In this work, the influence of the textile electrodes on the measurements and on the estimation of the Cole (R(0), R(infinity), f(C) and alpha) and body composition (TBW, ICW, ECW and FFM) parameters has been especially addressed. Complex Spectroscopy 4-electrode wrist-to-ankle electrical bioimpedance measurements taken with conventional Ag/AgCl and textile-electrodes on customized bracelets have been compared and analyzed in the frequency range 3 to 500 kHz. The obtained results suggest that the use of textile electrodes do not influence remarkably on the complex spectral measurements neither in the estimation of Cole nor body composition parameter. In any case any possible effect introduced by the use of textile is smaller than the effect of preparing the skin by the using abrasive conductive paste.
  •  
25.
  • Marquez Ruiz, Juan Carlos, et al. (författare)
  • Skin-Electrode Contact Area in Electrical Bioimpedance Spectroscopy. Influence in Total Body Composition Assessment.
  • 2011
  • Ingår i: Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS. - : IEEE. - 9781424441228 ; 2011, s. 1867-70
  • Konferensbidrag (refereegranskat)abstract
    • Electrical Bioimpedance Spectroscopy (EBIS) has been widely use for assessment of total body composition and fluid distribution. (EBIS) measurements are commonly performed with electrolytic electrodes placed on the wrist and the ankle with a rather small skin–electrode contact area. The use of textile garments for EBI requires the integration of textrodes with a larger contact area surrounding the limbs in order to compensate the absence of electrolytic medium commonly present in traditional Ag/AgCl gel electrodes. Recently it has been shown that mismatch between the measurements electrodes might cause alterations on the EBIS measurements. When performing EBIS measurements with textrodes certain differences have been observed, especially at high frequencies, respect the same EBIS measurements using Ag/AgCl electrodes. In this work the influence of increasing the skinelectrode area on the estimation of body composition parameters has been study performing experimental EBIS measurement. The results indicate that an increment on the area of the skin-electrode interface did produce noticeable changes in the bioimpedance spectra as well as in the body composition parameters. This influence must be taken into consideration when designing and testing textile-enable EBIS measurement systems.
  •  
26.
  • Pau, Ivan, et al. (författare)
  • Home e-health system integration in the Smart Home through a common media server.
  • 2009
  • Ingår i: EMBC: 2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20. - 9781424432967 ; 2009, s. 6171-4
  • Konferensbidrag (refereegranskat)abstract
    • Home e-health systems and services are revealed as one of the most important challenges to promote Quality of Life related to Health in the Information Society. Leading companies have worked on e-health systems although the majority of them are addressed to hospital or primary care settings. The solution detailed in this paper offers a personal health system to be integrated with Smart Home services platform to support home based e-care. Thus, the home e-health system and architecture detailed in this research work is ready to supply a seamless personal care solution both from the biomedical data analysis, service provision, security guarantee and information management s point of view. The solution is ready to be integrated within the Accessible Digital Home, a living lab managed by Universidad Politécnica de Madrid for R&D activities.
  •  
27.
  •  
28.
  • Seoane, Fernando, 1976-, et al. (författare)
  • Adaptive frequency distribution for Electrical Bioimpedance Spectroscopy measurements
  • 2012
  • Ingår i: Engineering in Medicine and Biology Society (EMBC), 2012 Annual International Conference of the IEEE. - : IEEE. - 9781424441198 ; 2012, s. 562-5
  • Konferensbidrag (refereegranskat)abstract
    • This paper presents a novel frequency distribution scheme intended to provide more accurate estimations of Cole parameters. Nowadays a logarithmic frequency distribution is mostly used in Electrical Bioimpedance Spectroscopy (EBIS) applications. However it is not optimized following any criterion. Our hypothesis is that an EBIS signal contains more information where the variation of the measurement regarding the frequency is larger; and that there ought to be more measuring frequencies where there is more information. Results show that for EBIS data with characteristic frequencies up to 200 kHz the error obtained with both frequency distribution schemes is similar. However, for EBIS data with higher values of characteristic frequency the error produced when estimating the values from EBIS measurements using an adaptive frequency distribution is smaller. Thus it may useful for EBIS applications with high values of characteristic frequency, e.g. cerebral bioimpedance.
  •  
29.
  • Seoane, Fernando, 1976-, et al. (författare)
  • Brain electrical impedance at various frequencies : the effect of hypoxia
  • 2004
  • Ingår i: Proceedings of the 26th Annual International Conference of the IEEE EMBS, San Francisco, CA, USA • September 1-5, 2004. - : IEEE Engineering in Medicine and Biology Society. - 0780384393 ; 3, s. 2322-5
  • Konferensbidrag (refereegranskat)abstract
    • Non-invasive multi-frequency measurements of transcephalic impedance, both reactance and resistance, can efficiently detect cell swelling of brain tissue and can be used for early detection of threatening brain damage. We have performed experiments on piglets to monitor transcephalic impedance during hypoxia. The obtained results have confirmed the hypothesis that changes in the size of cells modify the tissue impedance. During tissue inflammation after induced hypoxia, cerebral tissue exhibits changes in both reactance and resistance. Those changes are remarkably high, up to 71% over the baseline, and easy to measure especially at certain frequencies. A better understanding of the electrical behaviour of cerebral tissue during cell swelling would lead us to develop effective non-invasive clinical tools and methods for early diagnosis of cerebral edema and brain damage prevention.
  •  
30.
  • Seoane, Fernando, 1976-, et al. (författare)
  • Current Source for Wideband Electrical Bioimpedance Spectroscopy Based on a Single Operational Amplifier
  • 2006
  • Ingår i: WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6. - : IFMBE. - 9783540368397 ; , s. 707-710
  • Konferensbidrag (refereegranskat)abstract
    • Traditionally, measurements of electrical bioimpedance for medical diagnostic purposes have used only low frequencies, usually below 100 kHz. The analysis focused only on the resistive part of the impedance; very often at low frequencies the reactive part of the impedance is negligible. Recent studies of the electrical bioimpedance spectrum, both real and imaginary parts, have indicated new potential applications e.g. detection of meningitis, skin cancer assessment and brain cellular edema detection. An important functional unit in a wideband impedance spectrometer is the current source used to inject the current into the tissue under study. A current source must provide an output current virtually constant over the frequency range of interest and independent of the load at the output. Several designs have been proposed over the years but the performance of them all degraded markedly near bellow 1 MHz e.g. Ackmann in 1993, Bragos et al in 1994 and Bertemes-Filho et al in 2000. The development of electronic technology has made available devices that allow us to obtain a current source with large output impedance, larger than 100 k Omega, above I MHz and based in a simple single Op-Amp circuit topology. Simulation results and experimental measurements are compared and the most important parameters of the VCCS are analytically studied and experimentally tested, including the dependency to changes in the circuit elements and the incidence of the Op-Amp parameters on the current source features.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 21-30 av 37
Typ av publikation
konferensbidrag (37)
Typ av innehåll
refereegranskat (27)
övrigt vetenskapligt/konstnärligt (10)
Författare/redaktör
Lindecrantz, Kaj, 19 ... (15)
Seoane, Fernando, 19 ... (12)
Seoane, Fernando (10)
Thordstein, Magnus (6)
Kjellmer, Ingemar, 1 ... (5)
visa fler...
Löfhede, Johan (5)
Abtahi, Farhad (4)
Löfgren, Nils, 1969 (4)
Lu, Ke (3)
Seoane Martinez, Fer ... (3)
Flisberg, Anders, 19 ... (3)
Löfgren, N. (3)
Marquez, Juan Carlos (3)
Löfhede, Johan, 1978 (3)
Abtahi, Farhad, 1981 ... (2)
Dizon, M (2)
Johansson, M (2)
Kjellmer, I (2)
Thordstein, M. (2)
Atefi, Seyed Reza, 1 ... (2)
Buendia, Ruben, 1983 ... (2)
Ferreira, Javier, 19 ... (2)
bragos, Ramon (2)
Olsson, T (1)
Rödby, Kristian (1)
Ji, Guangchao (1)
Aslamy, Benjamin (1)
Boujabir, Imaneh (1)
Anund, Anna (1)
Fors, Carina (1)
Abtahi, Shirin (1)
Berndtsson, Andreas (1)
Löfgren, Nils (1)
Abtahi, F. (1)
Gyllesten, I. C. (1)
Björlin, Anders (1)
Östlund, Anders (1)
Persson, Mikael (1)
Mallard, Carina, 196 ... (1)
Ekman, Inger, 1952 (1)
Degerman, Johan, 197 ... (1)
Kjellmer, Ingemar (1)
Persson, Mikael, 195 ... (1)
Sjöqvist, Bengt-Arne ... (1)
Ekman, I. (1)
Buendia, Ruben (1)
Seoane Martinéz, Fer ... (1)
Dean, Justin M (1)
Ferreira Gonzalez, J ... (1)
visa färre...
Lärosäte
Kungliga Tekniska Högskolan (20)
Chalmers tekniska högskola (15)
Karolinska Institutet (8)
Göteborgs universitet (5)
Språk
Engelska (35)
Svenska (2)
Forskningsämne (UKÄ/SCB)
Teknik (27)
Medicin och hälsovetenskap (21)
Naturvetenskap (3)
Samhällsvetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy