1.
  • Bröde, Peter, et al. (författare)
  • Non-evaporative effects of a wet mid layer on heat transfer through protective clothing
  • 2008
  • Ingår i: European Journal of Applied Physiology. - : Springer Science and Business Media LLC. - 1439-6327 .- 1439-6319. ; 104:2, s. 341-349
  • Tidskriftsartikel (refereegranskat)abstract
    • In order to assess the non-evaporative components of the reduced thermal insulation of wet clothing, experiments were performed with a manikin and with human subjects in which two layers of underwear separated by an impermeable barrier were worn under an impermeable overgarment at 20 °C, 80% RH and 0.5 ms-1 air velocity. By comparing manikin measurements with dry and wetted mid underwear layer, the increase in heat loss caused by a wet layer kept away from the skin was determined, which turned out to be small (5-6 Wm-2), irrespective of the inner underwear layer being dry or wetted, and was only one third of the evaporative heat loss calculated from weight change, i.e. evaporative cooling efficiency was far below unity. In the experiments with 8 males, each subject participated in two sessions with the mid underwear layer either dry or wetted, where they stood still for the first 30 minutes and then performed treadmill work for 60 minutes. Reduced heat strain due to lower insulation with the wetted mid layer was observed with decreased microclimate and skin temperatures, lowered sweat loss and cardiac strain. Accordingly, total clothing insulation calculated over the walking period from heat balance equations was reduced by 0.02 m2 °C W-1 (16%), while for the standing period the same decrease in insulation, representing 9% reduction only showed up after allowing for the lower evaporative cooling efficiency in the calculations. As evaporation to the environment and inside the clothing was restricted, the observed small alterations may be attributed to the wet mid layer’s increased conductivity, which, however, appears to be of minor importance compared to the evaporative effects in the assessment of the thermal properties of wet clothing.
  •  
2.
  • Havenith, George, et al. (författare)
  • Apparent latent heat of evaporation from clothing: attenuation and “heat pipe” effects
  • 2008
  • Ingår i: Journal of Applied Physiology. - : American Physiological Society. - 1522-1601 .- 8750-7587. ; 104:1, s. 142-149
  • Tidskriftsartikel (refereegranskat)abstract
    • Investigating claims that a clothed person’s mass loss does not always represent their evaporative heat loss (EVAP), a thermal manikin study was performed measuring heat balance components in more detail than human studies would permit. Using clothing with different levels of vapor permeability and measuring heat losses from skin controlled at 34°C in ambient temperatures of 10, 20, and 34°C with constant vapor pressure (1 kPa), additional heat losses from wet skin compared with dry skin were analyzed. EVAP based on mass loss (Emass) measurement and direct measurement of the extra heat loss by the manikin due to wet skin (Eapp) were compared. A clear discrepancy was observed. Emass overestimated Eapp in warm environments, and both under and overestimations were observed in cool environments, depending on the clothing vapor permeability. At 34°C, apparent latent heat ((lambda)app) of pure evaporative cooling was lower than the physical value ((lambda); 2,430 J/g) and reduced with increasing vapor resistance up to 45%. At lower temperatures, (lambda)app increases due to additional skin heat loss via evaporation of moisture that condenses inside the clothing, analogous to a heat pipe. For impermeable clothing, (lambda)app even exceeds (lambda) by four times that value at 10°C. These findings demonstrate that the traditional way of calculating evaporative heat loss of a clothed person can lead to substantial errors, especially for clothing with low permeability, which can be positive or negative, depending on the climate and clothing type. The model presented explains human subject data on EVAP that previously seemed contradictive.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2
Typ av publikation
tidskriftsartikel (2)
Typ av innehåll
refereegranskat (2)
Författare/redaktör
Kuklane, Kalev (2)
Holmér, Ingvar (2)
Bröde, Peter (2)
Meinander, Harriet (2)
Havenith, George (2)
Candas, Victor (2)
visa fler...
den Hartog, Emiel (1)
Griefahn, Barbara (1)
den Hartog, Emiel A. (1)
visa färre...
Lärosäte
Språk
Engelska (2)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (2)
År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy