SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Lu W) ;lar1:(ri)"

Sökning: WFRF:(Lu W) > RISE

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Wang, J., et al. (författare)
  • Final report of the CCQM-K145 : Toxic and essential elements in bovine liver
  • 2020
  • Ingår i: Metrologia. - : IOP Publishing Ltd. - 0026-1394 .- 1681-7575. ; 57:1 A
  • Tidskriftsartikel (refereegranskat)abstract
    • Liver plays a major role in metabolism and acts as a source of energy for the body by storing glycogen. With the growing interest and investigation in the biological effects in recent years, it is important and necessary to develop accurate and comparable analytical methods for elements in bio-samples. It has, however, been 10 years since the tissue sample (bovine liver) of CCQM-K49 key comparison. The purpose of CCQM-K145 is to ensure the comparable and traceable measurement results for essential and toxic elements such as P, S, Zn, Mn, Ni, Mo, Sr, Cr, Co, Pb, As and Hg in bovine liver among NMIs and other designated measurement bodies worldwide. The comparison was agreed by IAWG as 6th IAWG Benchmarking Exercise with Zn and Ni as exemplary elements at the meeting in Korea in the early October 2016. The results of CCQM-K145 are expected to cover the measurement capability and support CMCs claiming for inorganic elements in the similar biological tissue materials and food samples. 30 NMIs and DIs registered in CCQM-K145. With respect to the methodology, a variety of techniques such as IDMS, ICP-OES, ICP-MS(non-ID), AAS and NAA were adopted by the participants. For Zn, Ni, Sr, Pb and Hg measurements, most participants chose ID-ICP-MS method, which showed the better performance in terms of consistency and reliability of the measurement results. In aspect of the traceability for the measurement results in CCQM-K145, most participants used their own (in house) CRMs or other NMI's CRMs to guarantee trace to SI unit. Most participants used similar matrix CRMs for quality control or method validation. Base on different statistic way to calculate the reference mass fraction values and associated uncertainties for each measurand, removal of the suspected extreme values, and discussion at the IAWG meetings, the median values are proposed as the KCRV for Zn, Ni, Mn, Mo, Cr, Pb and Hg; the arithmetic mean values are proposed as the KCRV for P, S, Sr, Co and As. In general, the performances of the majority of CCQM-K145 participants are very good, illustrating their measurement capabilities for Zn, Ni, P, S, Mn, Mo, Sr, Cr, As, Co, Pb and Hg in a complex biological tissue matrix. Bovine liver contains many kinds of nutrients and microelements, it can be regarded as a typical representative material of biological tissue and food. In CCQM-K145, the analytes involved alkali metals and transition elements, metalloids/semi-metals and non metals with a range of mass fraction from mg/g to μg/kg. CCQM-K145 also tested the ability of NMIs/DIs to determine elements that were easy to be lost and polluted, and interfered significantly. The chemical pretreatment methods of samples used in the comparison is suitable for general food and biological matrix samples. A variety of measurement methods used in the comparison represent the main instrumental technology for elemental analysis. Therefore, for supporting CMC claim, CCQM-K145 is readily applicable to measurement of more elements in a wide range of biological materials (including liquids and solids) and meat products. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
  •  
2.
  • Zhang, Lu, et al. (författare)
  • Kernel Adaptive Filtering for Nonlinearity-Tolerant Optical Direct Detection Systems
  • 2018
  • Ingår i: ). - : Institute of Electrical and Electronics Engineers Inc.. ; , s. 1-3
  • Konferensbidrag (refereegranskat)abstract
    • Kernel adaptive filtering (KAF) is proposed for nonlinearity-tolerant optical direct detection. for 7×128 Gbit/s PAM4 transmission over 33.6km 7-core-fiber, KAF only needs 10 equalizer taps to reach KP4-FEC limit (BER@2.2e-4), whereas decision-feedback-equalizer needs 43 equalizer taps to reach HD-FEC limit (BER@3.8e-3).
  •  
3.
  • Ozolins, Oskars, et al. (författare)
  • 7×149 Gbit/s PAM4 transmission over 1 km multicore fiber for short-reach optical interconnects
  • 2018
  • Ingår i: Optics InfoBase Conference Papers. - : Optics Info Base, Optical Society of America. - 9781557528209
  • Konferensbidrag (refereegranskat)abstract
    • We transmit 80 Gbaud/λ/core PAM4 signal enabled by 1.55 μm EML over 1 km 7-core fiber. The solution achieves single-wavelength and single-fiber 1.04 Tbit/s post-FEC transmission enhancing bandwidth-density for short-reach optical interconnects.
  •  
4.
  • Wagner, J., et al. (författare)
  • First 230? : GHz VLBI fringes on 3C 279 using the APEX Telescope (Research Note)
  • 2015
  • Ingår i: Astronomy and Astrophysics. - : EDP Sciences. - 0004-6361 .- 1432-0746. ; 581
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims. We report about a 230? GHz very long baseline interferometry (VLBI) fringe finder observation of blazar 3C 279 with the APEX telescope in Chile, the phased submillimeter array (SMA), and the SMT of the Arizona Radio Observatory (ARO). Methods. We installed VLBI equipment and measured the APEX station position to 1? cm accuracy (1σ). We then observed 3C 279 on 2012 May 7 in a 5? h 230? GHz VLBI track with baseline lengths of 2800? Mλ to 7200? Mλ and a finest fringe spacing of 28.6? μas. Results. Fringes were detected on all baselines with signal-to-noise ratios of 12 to 55 in 420? s. The correlated flux density on the longest baseline was ∼0.3? Jy beam-1, out of a total flux density of 19.8? Jy. Visibility data suggest an emission region ≤ 38? μas in size, and at least two components, possibly polarized. We find a lower limit of the brightness temperature of the inner jet region of about 1010? K. Lastly, we find an upper limit of 20% on the linear polarization fraction at a fringe spacing of ∼ 38? μas. Conclusions. With APEX the angular resolution of 230? GHz VLBI improves to 28.6? μas. This allows one to resolve the last-photon ring around the Galactic Center black hole event horizon, expected to be 40? μas in diameter, and probe radio jet launching at unprecedented resolution, down to a few gravitational radii in galaxies like M 87. To probe the structure in the inner parsecs of 3C 279 in detail, follow-up observations with APEX and five other mm-VLBI stations have been conducted (March 2013) and are being analyzed.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy