SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "swepub ;pers:(Hultman Lars)"

Sökning: swepub > Hultman Lars

  • Resultat 11-20 av 896
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
11.
  •  
12.
  • Sarius, N. G., et al. (författare)
  • Contact Resistance of Ti-Si-C-Ag and Ti-Si-C-Ag-Pd Nanocomposite Coatings
  • 2012
  • Ingår i: Journal of Electronic Materials. - : Springer Science and Business Media LLC. - 0361-5235 .- 1543-186X. ; 41:3, s. 560-567
  • Tidskriftsartikel (refereegranskat)abstract
    • Ti-Si-C-Ag-Pd and Ti-Si-C-Ag nanocomposite coatings were deposited by direct-current magnetron sputtering on Cu substrates with an electroplated Ni layer. Analytical electron microscopy, x-ray diffraction, and x-ray photoelectron spectroscopy show that the nanocomposites consist of TiC, Ag:Pd, and amorphous SiC. The contact resistance of these coatings against a spherical Au-Co surface was measured for applied contact forces up to 5 N. Ti-Si-C-Ag-Pd coatings with Ag:Pd top coating had similar to 10 times lower contact resistance at contact forces below 1 N (similar to 10 m Omega at similar to 0.1 N), and 2 to 3 times lower for contact forces around 5 N (< 1 m Omega at 5 N), compared with the Ti-Si-C-Ag coating.
  •  
13.
  • Tengstrand, Olof, et al. (författare)
  • Structure and electrical properties of Nb-Ge-C nanocomposite coatings
  • 2014
  • Ingår i: Journal of Vacuum Science & Technology. A. Vacuum, Surfaces, and Films. - : American Vacuum Society. - 0734-2101 .- 1520-8559. ; 32:4, s. 041509-
  • Tidskriftsartikel (refereegranskat)abstract
    • Nb-Ge-C nanocomposite thin films were deposited by dc magnetron sputtering using three elemental targets. The films consist of substoichiometric NbCx in a nanometer-thick matrix of amorphous C and Ge. Films with no Ge contain grains that are elongated in the growth direction with a (111) preferred crystallographic orientation. With the addition of similar to 12 at. % Ge, the grains are more equiaxed and exhibit a more random orientation. At even higher Ge contents, the structure also becomes denser. The porous structure of the low Ge content films result in O uptake from the ambient. With higher C content in the films both the amount of amorphous C and C/Nb-ratio increases. The contact resistance was measured by four-point technique as a function of contact force between 0 and 10 N. The lowest contact resistance (1.7 m Omega) is obtained at 10 N. The resistivity varies between 470 and 1700 mu Omega center dot cm depending on porosity and O content.  
  •  
14.
  • Frodelius, Jenny, et al. (författare)
  • Ti2AlC coatings deposited by High Velocity Oxy-Fuel spraying
  • 2008
  • Ingår i: Surface & Coatings Technology. - : Elsevier. - 0257-8972 .- 1879-3347. ; 202:24, s. 5976-5981
  • Tidskriftsartikel (refereegranskat)abstract
    • High Velocity Oxy-Fuel has been utilized to spray coatings from Ti2AlC (MAXTHAL 211®) powders. X-ray diffraction showed that the coatings consist predominantly of Ti2AlC with inclusions of the phases Ti3AlC2, TiC, and Al–Ti alloys. The fraction of Ti2AlC in coatings sprayed with a powder size of 38 μm was found to increase with decreasing power of the spraying flame as controlled by the total gas flow of H2 and O2. A more coarse powder (56 μm) is less sensitive to the total gas flow and retains higher volume fraction of MAX-phase in the coatings, however, at the expense of increasing porosity. X-ray pole figure measurements showed a preferred crystal orientation in the coatings with the Ti2AlC (000l) planes aligned to the substrate surface. Bending tests show a good adhesion to stainless steel substrates and indentation yields a hardness of 3–5 GPa for the coatings sprayed with a powder size of 38 μm.
  •  
15.
  • Albani, Giorgia, et al. (författare)
  • Evolution in boron-based GEM detectors for diffraction measurements : From planar to 3D converters
  • 2016
  • Ingår i: Measurement science and technology. - : IOP Publishing. - 0957-0233 .- 1361-6501. ; 27:11
  • Tidskriftsartikel (refereegranskat)abstract
    • The so-called '3He-crisis' has motivated the neutron detector community to undertake an intense R&D programme in order to develop technologies alternative to standard 3He tubes and suitable for neutron detection systems in future spallation sources such as the European spallation source (ESS). Boron-based GEM (gas electron multiplier) detectors are a promising '3He-free' technology for thermal neutron detection in neutron scattering experiments. In this paper the evolution of boron-based GEM detectors from planar to 3D converters with an application in diffraction measurements is presented. The use of 3D converters coupled with GEMs allows for an optimization of the detector performances. Three different detectors were used for diffraction measurements on the INES instrument at the ISIS spallation source. The performances of the GEM-detectors are compared with those of conventional 3He tubes installed on the INES instrument. The conceptual detector with the 3D converter used in this paper reached a count rate per unit area of about 25% relative to the currently installed 3He tube. Its timing resolution is similar and the signal-to-background ratio (S/B) is 2 times lower.
  •  
16.
  • Anastasopoulos, M., et al. (författare)
  • Multi-Grid detector for neutron spectroscopy : Results obtained on time-of-flight spectrometer CNCS
  • 2017
  • Ingår i: Journal of Instrumentation. - : IOP PUBLISHING LTD. - 1748-0221 .- 1748-0221. ; 12:4
  • Tidskriftsartikel (refereegranskat)abstract
    • The Multi-Grid detector technology has evolved from the proof-of-principle and characterisation stages. Here we report on the performance of the Multi-Grid detector, the MG.CNCS prototype, which has been installed and tested at the Cold Neutron Chopper Spectrometer, CNCS at SNS. This has allowed a side-by-side comparison to the performance of 3He detectors on an operational instrument. The demonstrator has an active area of 0.2 m2. It is specifically tailored to the specifications of CNCS. The detector was installed in June 2016 and has operated since then, collecting neutron scattering data in parallel to the He-3 detectors of CNCS. In this paper, we present a comprehensive analysis of this data, in particular on instrument energy resolution, rate capability, background and relative efficiency. Stability, gamma-ray and fast neutron sensitivity have also been investigated. The effect of scattering in the detector components has been measured and provides input to comparison for Monte Carlo simulations. All data is presented in comparison to that measured by the 3He detectors simultaneously, showing that all features recorded by one detector are also recorded by the other. The energy resolution matches closely. We find that the Multi-Grid is able to match the data collected by 3He, and see an indication of a considerable advantage in the count rate capability. Based on these results, we are confident that the Multi-Grid detector will be capable of producing high quality scientific data on chopper spectrometers utilising the unprecedented neutron flux of the ESS.
  •  
17.
  • Höglund, Carina, et al. (författare)
  • Growth and oxidization stability of cubic Zr1-xGdxN solid solution thin films
  • 2015
  • Ingår i: Journal of Applied Physics. - : American Institute of Physics (AIP). - 0021-8979 .- 1089-7550. ; 117:19
  • Tidskriftsartikel (refereegranskat)abstract
    • We report Zr1-xGdxN thin films deposited by magnetron sputter deposition. We show a solid solubility of the highly neutron absorbing GdN into ZrN along the whole compositional range, which is in excellent agreement with our recent predictions by first-principles calculations. An oxidization study in air shows that Zr1-xGdxN with x reaching from 1 to close to 0 fully oxidizes, but that the oxidization is slowed down by an increased amount of ZrN or stopped by applying a capping layer of ZrN. The crystalline quality of Zr0.5Gd0.5N films increases with substrate temperatures increasing from 100 degrees C to 900 degrees C.
  •  
18.
  • Höglund, Carina, et al. (författare)
  • Stability of (B4C)-B-10 thin films under neutron radiation
  • 2015
  • Ingår i: Radiation Physics and Chemistry. - : Elsevier BV. - 0969-806X .- 1879-0895. ; 113, s. 14-19
  • Tidskriftsartikel (refereegranskat)abstract
    • Thin films of (B4C)-B-10 have shown to be very suitable as neutron-converting material in the next generation of neutron detectors, replacing the previous predominantly used He-3. In this contribution we show under realistic conditions that (B4C)-B-10 films are not damaged by the neutron irradiation and interactions, which they will be exposed to under many years in a neutron detector. 1 mu m thick (B4C)-B-10 thin films were deposited onto Al or Si substrates using dc magnetron sputtering. As-deposited films were exposed to a cold neutron beam with fluences of up to 1.1 x 10(14) cm(-2) and a mean wavelength of 6.9 angstrom. Both irradiated and as-deposited reference samples were characterized with time-of-flight elastic recoil detection analysis, scanning electron microscopy, transmission electron microscopy, X-ray photoemission spectroscopy, and X-ray diffraction. We show that only 1.8 ppm of the B-10 atoms were consumed and that the film composition does not change by the neutron interaction within the measurement accuracy. The irradiation does not deteriorate the film adhesion and there is no indication that it results in increased residual stress values of the as-deposited films of 0.095 GPa. From what is visible with the naked eye and down to atomic level studies, no change from the irradiation could be found using the above-mentioned characterization techniques. (C) 2015 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
  •  
19.
  • Schmidt, Susann, et al. (författare)
  • Low-temperature growth of boron carbide coatings by direct current magnetron sputtering and high-power impulse magnetron sputtering
  • 2016
  • Ingår i: Journal of Materials Science. - New York : Springer Science and Business Media LLC. - 0022-2461 .- 1573-4803. ; 51:23, s. 10418-10428
  • Tidskriftsartikel (refereegranskat)abstract
    • B4C coatings for 10B-based neutron detector applications were deposited using high-power impulse magnetron sputtering (HiPIMS) and direct current magnetron sputtering (DCMS) processes. The coatings were deposited on Si(001) as well as on flat and macrostructured (grooved) Al blades in an industrial coating unit using B4C compound targets in Ar. The HiPIMS and DCMS processes were conducted at substrate temperatures of 100 and 400 °C and the Ar pressure was varied between 300 and 800 mPa. Neutron detector-relevant coating characterization was performed and the coating properties were evaluated with regard to their growth rate, density, level of impurities, and residual coating stress. The coating properties are mainly influenced by general process parameters such as the Ar pressure and substrate temperature. The deposition mode shows only minor effects on the coating quality and no effects on the step coverage. At a substrate temperature of 100 °C and an Ar pressure of 800 mPa, well-adhering and functional coatings were deposited in both deposition modes; the coatings showed a density of 2.2 g/cm3, a B/C ratio of ~3.9, and the lowest compressive residual stresses of 180 MPa. The best coating quality was obtained in DCMS mode using an Ar pressure of 300 mPa and a substrate temperature of 400 °C. Such process parameters yielded coatings with a slightly higher density of 2.3 g/cm3, a B/C ratio of ~4, and the compressive residual stresses limited to 220 MPa.
  •  
20.
  • Birch, J, et al. (författare)
  • Investigation of background in large-area neutron detectors due to alpha emission from impurities in aluminium
  • 2015
  • Ingår i: Journal of Instrumentation. - : IOP PUBLISHING LTD. - 1748-0221. ; 10
  • Tidskriftsartikel (refereegranskat)abstract
    • Thermal neutron detector based on films of (B4C)-B-10 have been developed as an alternative to He-3 detectors. In particular, The Multi-Grid detector concept is considered for future large area detectors for ESS and ILL instruments. An excellent signal-to-background ratio is essential to attain expected scientific results. Aluminium is the most natural material for the mechanical structure of of the Multi-Grid detector and other similar concepts due to its mechanical and neutronic properties. Due to natural concentration of alpha emitters, however, the background from alpha particles misidentified as neutrons can be unacceptably high. We present our experience operating a detector prototype affected by this issue. Monte Carlo simulations have been used to confirm the background as alpha particles. The issues have been addressed in the more recent implementations of the Multi-Grid detector by the use of purified aluminium as well as Ni-plating of standard aluminium. The result is the reduction in background by two orders of magnitude. A new large-area prototype has been built incorporating these modifications.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 11-20 av 896
Typ av publikation
tidskriftsartikel (716)
annan publikation (46)
doktorsavhandling (43)
konferensbidrag (39)
licentiatavhandling (29)
forskningsöversikt (9)
visa fler...
bokkapitel (9)
patent (5)
visa färre...
Typ av innehåll
refereegranskat (745)
övrigt vetenskapligt/konstnärligt (144)
populärvet., debatt m.m. (7)
Författare/redaktör
Lu, Jun (164)
Birch, Jens (123)
Greczynski, Grzegorz (93)
Eklund, Per (88)
Jensen, Jens (81)
visa fler...
Petrov, Ivan (80)
Rosén, Johanna (70)
Hultman, Lars, 1960- (65)
Palisaitis, Justinas (61)
Högberg, Hans (57)
Hultman, Lars, Profe ... (53)
Greene, Joseph E (52)
Persson, Per O A (46)
Hultman, Lars, Profe ... (46)
Odén, Magnus (44)
Persson, Per (42)
Jansson, Ulf (42)
Alling, Björn (35)
Schmidt, Susann (31)
Höglund, Carina (29)
Chirita, Valeriu (27)
Hsiao, Ching-Lien (27)
Broitman, Esteban (25)
Sangiovanni, Davide (25)
Pozina, Galia (24)
Dahlqvist, Martin (23)
Hellgren, N. (21)
Persson, Per O. Å. (21)
Barsoum, Michel W. (21)
Czigány, Zs. (21)
Greczynski, Grzegorz ... (21)
Ghafoor, Naureen (20)
Abrikosov, Igor (19)
Eriksson, Fredrik (19)
Yakimova, Rositsa (19)
Birch, Jens, 1960- (19)
Tasnádi, Ferenc (18)
Janzén, Erik (17)
Monemar, Bo (17)
Bakhit, Babak (17)
Neidhardt, Jörg (17)
Broitman, E. (17)
Beckers, Manfred (16)
Czigany, Zsolt (16)
Halim, Joseph (15)
Emmerlich, Jens (15)
Flink, Axel (15)
Stafström, Sven (15)
Magnuson, Martin, 19 ... (15)
visa färre...
Lärosäte
Linköpings universitet (862)
Uppsala universitet (87)
Kungliga Tekniska Högskolan (34)
Lunds universitet (19)
Chalmers tekniska högskola (11)
RISE (9)
visa fler...
Luleå tekniska universitet (7)
Jönköping University (6)
Mittuniversitetet (5)
Örebro universitet (2)
Göteborgs universitet (1)
Umeå universitet (1)
Högskolan Väst (1)
Karlstads universitet (1)
visa färre...
Språk
Engelska (890)
Svenska (2)
Latin (2)
Tyska (1)
Odefinierat språk (1)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (359)
Teknik (113)
Humaniora (3)
Medicin och hälsovetenskap (1)
Samhällsvetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy