SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:1094 687X OR L773:1558 4615 OR L773:9781424492718 OR L773:9781424492701 "

Sökning: L773:1094 687X OR L773:1558 4615 OR L773:9781424492718 OR L773:9781424492701

  • Resultat 1-10 av 16
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Seoane, Fernando, et al. (författare)
  • Slightly superior performance of bioimpedance spectroscopy over single frequency regression equations for assessment of total body water.
  • 2015
  • Ingår i: Engineering in Medicine and Biology Society (EMBC), 2015 37th Annual International Conference of the IEEE. 25-29 Aug. 2015, Milan, Italy.. - : IEEE. - 1094-687X .- 1558-4615. - 9781424492718 - 9781424492701 ; 2015, s. 3707-10
  • Konferensbidrag (refereegranskat)abstract
    • Electrical bioimpedance has been used for several decades to assess body fluid distribution and body composition by using single frequency and bioimpedance spectroscopic (BIS) techniques. It remains uncertain whether BIS methods have better performance compare to single frequency regression equations. In this work the performance of two BIS methods and four different 50 kHz single frequency prediction equations was studied in a data set of wrist-to-ankle tetrapolar BIS measurements (5-1000 kHz) together with reference values of total body water obtained by tritium dilution in 92 patients. Data were compared using regression techniques and Bland-Altman plots. The results of this study showed that all methods produced similarly high correlation and concordance coefficients, indicating good accuracy as a method. Limits of agreement analysis indicated that the population level performance of Sun's prediction equations was very similar to the performance of both BIS methods. However, BIS methods in practice have slightly better predictive performance than the single-frequency equations as judged by higher correlation and the limits of agreement from the Bland-Altman analysis. In any case, the authors believe that an accurate evaluation of performance of the methods cannot be done as long as the evaluation is done using Bland-Altman analysis, the commonly accepted technique for this kind of performance comparisons.
  •  
2.
  •  
3.
  • Baig, M.M., et al. (författare)
  • Tablet-based Patient Monitoring and Decision Support Systems in Hospital Care
  • 2015
  • Ingår i: 2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC). - 9781424492701 ; , s. 1215-1218
  • Konferensbidrag (refereegranskat)abstract
    • Remote patient monitoring with evidence-based decision support is revolutionizing healthcare. This novel approach could enable both patients and healthcare providers to improve quality of care and reduce costs. Clinicians can also view patients' data within the hospital network on tablet computers as well as other ubiquitous devices. Today, a wide range of applications are available on tablet computers which are increasingly integrating into the healthcare mainstream as clinical decision support systems. Despite the benefits of table-based healthcare applications, there are concerns around the accuracy, security and stability of such applications. In this study, we developed five tablet-based application screens for remote patient monitoring at hospital care settings and identified related issues and challenges. The ultimate aim of this research is to integrate decision support algorithms into the monitoring system in order to improve inpatient care and the effectiveness of such applications.
  •  
4.
  •  
5.
  • Gavrilis, Dimitris, et al. (författare)
  • A One-Class Approach to Cardiotocogram Assessment
  • 2015
  • Ingår i: 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. - Piscataway, NJ : IEEE Communications Society. - 9781424492718 ; , s. 518-521
  • Konferensbidrag (refereegranskat)abstract
    • Cardiotocogram (CTG) is the most widely used means for the assessment of fetal condition. CTG consists of two traces one depicting the Fetal Heart Rate (FHR), and the other the Uterine Contractions (UC) activity. Many automatic methods have been proposed for the interpretation of the CTG. Most of them rely either on a binary classification approach or on a multiclass approach to come up with a decision about the class that the tracing belongs to. This work investigates the use of a one-class approach to the assessment of CTGs building a model only for the healthy data. The preliminary results are promising indicating that normal traces could be used as part of an automatic system that can detect deviations from normality.
  •  
6.
  • Hamed, Zaid, et al. (författare)
  • A Programmable Low Power Current Source for Bioimpedance Measurement : Towards a Wearable Personalized Health
  • 2015
  • Ingår i: 2015 37th Annual International Conference of The IEEE ENGINEERING in Medicine and Biology Society (EMBC). - 9781424492701 ; , s. 2038-2042
  • Konferensbidrag (refereegranskat)abstract
    • Bioimpedance is a noninvasive measurement method that facilitates body composition analysis, besides being indicative of many other health parameters. In this work a novel programmable, low complexity, high output impedance, high voltage compliance and wideband current source for bioimpedance applications is presented. Previously, we designed, fabricated and tested in vivo a bio-patch for acquisition of multiple bio-signals [1]. Upon integration with our previous work, this circuit is envisioned to constitute part of a personalized health assistant. Simulation at worst case corners and real operation conditions was carried out using UMC-180 nm 1 poly 6 metal CMOS process. Full duty cycle, shortened or stepped square waves can be generated. Amplitude control of 8 different current levels is supported. Frequency can be tuned up to 1 MHz and an output impedance of 2.8 MO @ 250 KHz is achieved at full current capacity. Total current consumption is comparable to the injected current, making the circuit highly efficient.
  •  
7.
  • Johansson, Anders J (författare)
  • Wave-propagation from medical implants -influence of body shape on radiation pattern
  • 2002
  • Ingår i: Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings. - 1094-687X. ; 2, s. 1409-1410
  • Konferensbidrag (refereegranskat)abstract
    • The influence of a patient's body shape and position on the radiation pattern from an implanted radio transmitter has been simulated. Simulations and comparisons have been made with different body shapes (male, female and child) and different arm positions. It can be concluded from the results that the difference between different body shapes are at least as large as the influence of a patients arm movements.
  •  
8.
  • Mastinu, Enzo, 1987, et al. (författare)
  • Analog Front-Ends comparison: on the way to a portable, lowpower and low-cost EMG controller based on Pattern Recognition
  • 2015
  • Ingår i: Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS. - 1557-170X. - 9781424492718 ; 2015-November, s. 2111-2114
  • Konferensbidrag (refereegranskat)abstract
    • Compact and low-noise Analog Front-Ends (AFEs)are becoming increasingly important for the acquisition ofbioelectric signals in portable system. In this work, we comparetwo popular AFEs available on the market, namely theADS1299 (Texas Instruments) and the RHA2216 (IntanTechnologies). This work develops towards the identification ofsuitable acquisition modules to design an affordable, reliableand portable device for electromyography (EMG) acquisitionand prosthetic control. Device features such as Common ModeRejection (CMR), Input Referred Noise (IRN) and Signal toNoise Ratio (SNR) were evaluated, as well as the resultingaccuracy in myoelectric pattern recognition (MPR) for thedecoding of motion intention. Results reported better noiseperformances and higher MPR accuracy for the ADS1299 andsimilar SNR values for both devices.
  •  
9.
  • Ortiz Catalan, Max Jair, 1982, et al. (författare)
  • Offline Accuracy: A Potentially Misleading Metric in Myoelectric Pattern Recognition for Prosthetic Control.
  • 2015
  • Ingår i: Proceedings of the 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Milan, Italy, 15-19 August 2015. - 1557-170X. - 9781424492718 ; , s. 1140-1143
  • Konferensbidrag (refereegranskat)abstract
    • Offline accuracy has been the preferred performance measure in myoelectric pattern recognition (MPR) for the prediction of motion volition. In this study, different metrics relating the fundamental binary prediction outcomes were analyzed. Our results indicate that global accuracy is biased by 1) the unbalanced number of possible true positive and negative outcomes, and 2) the almost perfect specificity and negative predicted value, which were consistently found across algorithms, topologies, and movements (individual and simultaneous). Therefore, class-specific accuracy is advisable instead. Additionally, we propose the use of precision (positive predictive value) and sensitivity (recall) as a complement to accuracy to better describe the discrimination capabilities of MPR algorithms, as these consider the effect of false predictions. However, all the studied offline metrics failed to predict real-time decoding, and therefore real-time testing continue to be necessary to truly evaluate the clinical usability of MPR.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 16
Typ av publikation
konferensbidrag (14)
tidskriftsartikel (2)
Typ av innehåll
refereegranskat (15)
övrigt vetenskapligt/konstnärligt (1)
Författare/redaktör
Muceli, Silvia, 1981 (4)
Farina, Dario (3)
Ortiz Catalan, Max J ... (2)
Håkansson, Bo, 1953 (2)
GholamHosseini, Hami ... (1)
Lindén, Maria (1)
visa fler...
Wiklund, Urban (1)
Tuomi, Tiinamaija (1)
Groop, Leif (1)
Wymeersch, Henk, 197 ... (1)
Abtahi, Farhad (1)
Lu, Ke (1)
Guangchao, Li (1)
Rödby, Kristian (1)
Seoane, Fernando, 19 ... (1)
Ji, Guangchao (1)
Abtahi, Farhad, 1981 ... (1)
Seoane, Fernando (1)
Johansson, Anders J. (1)
Nikolakopoulos, Geor ... (1)
Suhr, Ole B. (1)
Bergquist, Filip, 19 ... (1)
Nyholm, Dag (1)
Constantinescu, Radu ... (1)
Thomas, Ilias (1)
Memedi, Mevludin, 19 ... (1)
Senek, Marina (1)
Johannsson, Gudmundu ... (1)
Mastinu, Enzo, 1987 (1)
Georgoulas, George (1)
Kravic, Jasmina (1)
Tenhunen, Hannu (1)
Tuomilehto, Jaakko (1)
Bosaeus, Ingvar, 195 ... (1)
Farina, D (1)
Ellegård, Lars, 1958 (1)
Gavrilis, Dimitris (1)
Ibáñez, J. (1)
Baig, M. M. (1)
Cincotti, F. (1)
Gabriel, Rafael (1)
Brånemark, Rickard, ... (1)
Hakaste, Liisa (1)
Ward, L. C. (1)
Champagne, B (1)
Yang, Geng (1)
Colamarino, E. (1)
Mrachacz-Kersting, N ... (1)
Mattia, D. (1)
Cobelli, Claudio (1)
visa färre...
Lärosäte
Chalmers tekniska högskola (7)
Göteborgs universitet (3)
Kungliga Tekniska Högskolan (3)
Lunds universitet (2)
Högskolan i Borås (2)
Karolinska Institutet (2)
visa fler...
Umeå universitet (1)
Uppsala universitet (1)
Luleå tekniska universitet (1)
Mälardalens universitet (1)
Örebro universitet (1)
Högskolan Dalarna (1)
visa färre...
Språk
Engelska (16)
Forskningsämne (UKÄ/SCB)
Teknik (12)
Medicin och hälsovetenskap (7)
Naturvetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy