SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:2405 6316 "

Sökning: L773:2405 6316

  • Resultat 1-10 av 36
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Adjeiwaah, Mary, 1980-, et al. (författare)
  • Sensitivity analysis of different quality assurance methods for magnetic resonance imaging in radiotherapy
  • 2020
  • Ingår i: Physics and Imaging in Radiation Oncology. - : Elsevier. - 2405-6316. ; 13, s. 21-27
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose: There are currently no standard quality assurance (QA) methods for magnetic resonance imaging (MRI) in radiotherapy (RT). This work was aimed at evaluating the ability of two QA protocols to detect common events that affect quality of MR images under RT settings.Materials and methods: The American College of Radiology (ACR) MRI QA phantom was repeatedly scanned using a flexible coil and action limits for key image quality parameters were derived. Using an exploratory survey, issues that reduce MR image quality were identified. The most commonly occurring events were introduced as provocations to produce MR images with degraded quality. From these images, detection sensitivities of the ACR MRI QA protocol and a commercial geometric accuracy phantom were determined.Results: Machine-specific action limits for key image quality parameters set at mean±3σ" role="presentation" style="box-sizing: border-box; margin: 0px; padding: 0px; display: inline-block; line-height: normal; font-size: 16.2px; word-spacing: normal; overflow-wrap: normal; white-space: nowrap; float: none; direction: ltr; max-width: none; max-height: none; min-width: 0px; min-height: 0px; border: 0px; position: relative;">mean±3σ were comparable with the ACR acceptable values. For the geometric accuracy phantom, provocations from uncorrected gradient nonlinearity effects and a piece of metal in the bore of the scanner resulted in worst distortions of 22.2 mm and 3.4 mm, respectively. The ACR phantom was sensitive to uncorrected signal variations, electric interference and a piece of metal in the bore of the scanner but could not adequately detect individual coil element failures.Conclusions: The ACR MRI QA phantom combined with the large field-of-view commercial geometric accuracy phantom were generally sensitive in identifying some common MR image quality issues. The two protocols when combined may provide a tool to monitor the performance of MRI systems in the radiotherapy environment.
  •  
2.
  •  
3.
  • Benedek, Hunor, et al. (författare)
  • The effect of prostate motion during hypofractionated radiotherapy can be reduced by using flattening filter free beams
  • 2018
  • Ingår i: Physics and imaging in radiation oncology. - : Elsevier BV. - 2405-6316. ; 6, s. 66-70
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose: Hypofractionated radiotherapy of prostate cancer reduces the overall treatment time but increases the per-fraction beam-on time due to the higher fraction doses. This increased fraction treatment time results in a larger uncertainty of the prostate position. The purpose of this study was to investigate the effect of prostate motion during flattening filter free (FFF) Volumetric Modulated Arc Therapy (VMAT) in ultrahypofractionation of prostate cancer radiotherapy with preserved plan quality compared to conventional flattened beams.Materials and methods: Nine prostate patients from the Scandinavian HYPO-RT-PC trial were re-planned using VMAT technique with both conventional and flattening filter free beams. Two fractionation schedules were used, one hypofractionated (42.7 Gy in 7 fractions), and one conventional (78.0 Gy in 39 fractions). Pre-treatment verification measurements were performed on all plans and the treatment time was recorded. Measurements with simulated prostate motion were performed for the plans with the longest treatment times. Results: All the 10FFF plans fulfilled the clinical gamma pass rate, 90% (3%, 2 mm), during all simulated prostate motion trajectories. The 10MV plans only fulfilled the clinical pass rate for three of the trajectories. The mean beam-on-time for the hypofractionated plans were reduced from 2.3 min to 1.0 min when using 10FFF compared to 10MV. No clinically relevant differences in dose distribution were identified when comparing the plans with different beam qualities. Conclusion: Flattening-filter free VMAT reduces treatment times, limiting the dosimetric effect of organ motion for ultrahypofractionated prostate cancer with preserved plan quality.
  •  
4.
  • Björeland, Ulrika, et al. (författare)
  • Impact of neoadjuvant androgen deprivation therapy on magnetic resonance imaging features in prostate cancer before radiotherapy
  • 2021
  • Ingår i: Physics and Imaging in Radiation Oncology. - : Elsevier. - 2405-6316. ; 17, s. 117-123
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose: In locally advanced prostate cancer (PC), androgen deprivation therapy (ADT) in combination with whole prostate radiotherapy (RT) is the standard treatment. ADT affects the prostate as well as the tumour on multiparametric magnetic resonance imaging (MRI) with decreased PC conspicuity and impaired localisation of the prostate lesion. Image texture analysis has been suggested to be of aid in separating tumour from normal tissue. The aim of the study was to investigate the impact of ADT on baseline defined MRI features in prostate cancer with the goal to investigate if it might be of use in radiotherapy planning.Materials and methods: Fifty PC patients were included. Multiparametric MRI was performed before, and three months after ADT. At baseline, a tumour volume was delineated on apparent diffusion coefficient (ADC) maps with suspected tumour content and a reference volume in normal prostatic tissue. These volumes were transferred to MRIs after ADT and were analysed with first-order -and invariant Haralick -features.Results: At baseline, the median value and several of the invariant Haralick features of ADC, showed a significant difference between tumour and reference volumes. After ADT, only ADC median value could significantly differentiate the two volumes.Conclusions: Invariant Haralick -features could not distinguish between baseline MRI defined PC and normal tissue after ADT. First-order median value remained significantly different in tumour and reference volumes after ADT, but the difference was less pronounced than before ADT.
  •  
5.
  • Brynolfsson, Patrik, et al. (författare)
  • Tensor-valued diffusion magnetic resonance imaging in a radiotherapy setting
  • 2022
  • Ingår i: Physics and imaging in radiation oncology. - : Elsevier BV. - 2405-6316. ; 24, s. 144-151
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purposeDiagnostic information about cell density variations and microscopic tissue anisotropy can be gained from tensor-valued diffusion magnetic resonance imaging (MRI). These properties of tissue microstructure have the potential to become novel imaging biomarkers for radiotherapy response. However, tensor-valued diffusion encoding is more demanding than conventional encoding, and its compatibility with MR scanners that are dedicated to radiotherapy has not been established. Thus, our aim was to investigate the feasibility of tensor-valued diffusion MRI with radiotherapy dedicated MR equipment.Material and methodsA tensor-valued diffusion protocol was implemented, and five healthy volunteers were scanned with different resolutions using conventional head coil and radiotherapy coil setup with fixation masks. Signal-to-noise-ratio (SNR) was evaluated to assess the risk of signal bias due to rectified noise floor. We also evaluated the repeatability and reproducibility of the microstructure parameters. One patient with brain metastasis was scanned to investigate the image quality and the transferability of the setup to diseased tissue.ResultsA resolution of 3×3×3 mm3 provided images with SNR>3 for 93% of the voxels using radiotherapy coil setup. The parameter maps and repeatability characteristics were comparable to those observed with a conventional head coil. The patient evaluation demonstrated successful parameter analysis also in tumor tissue, with SNR>3 for 93% of the voxels.ConclusionWe demonstrate that tensor-valued diffusion MRI is compatible with radiotherapy fixation masks and coil setup for investigations of microstructure parameters. The reported reproducibility may be used to plan future investigations of imaging biomarkers in brain cancer radiotherapy.
  •  
6.
  • Byskov, Camilla S., et al. (författare)
  • Treatment plan comparison of proton vs photon radiotherapy for lower-grade gliomas
  • 2021
  • Ingår i: Physics and Imaging in Radiation Oncology. - : Elsevier. - 2405-6316. ; 20, s. 98-104
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose: Patients with lower-grade gliomas are long-term survivors after radiotherapy and may benefit from the reduced dose to normal tissue achievable with proton therapy. Here, we aimed to quantify differences in dose to the uninvolved brain and contralateral hippocampus and compare the risk of radiation-induced secondary cancer for photon and proton plans for lower-grade glioma patients. Materials and methods: Twenty-three patients were included in this in-silico planning comparative study and had photon and proton plans calculated (50.4 Gy(RBE = 1.1), 28 Fx) applying similar dose constraints to the target and organs at risk. Automatically calculated photon plans were generated with a 3 mm margin from clinical target volume (CTV) to planning target volume. Manual proton plans were generated using robust optimisation on the CTV. Dose metrics of organs at risk were compared using population mean dose-volume histograms and Wilcoxon signed-rank test. Secondary cancer risk per 10,000 persons per year (PPY) was estimated using dose-volume data and a risk model for secondary cancer induction. Results: CTV coverage (V95%>98%) was similar for the two treatment modalities. Mean dose (D-mean) to the uninvolved brain was significantly reduced from 21.5 Gy (median, IQR 17.1-24.4 Gy) with photons compared to 10.3 Gy(RBE) (8.1-13.9 Gy(RBE)) with protons. D-mean to the contralateral hippocampus was significantly reduced from 6.5 Gy (5.4-11.7 Gy) with photons to 1.5 Gy(RBE) (0.4-6.8 Gy(RBE)) with protons. The estimated secondary cancer risk was reduced from 6.7 PPY (median, range 3.3-10.4 PPY) with photons to 3.0 PPY (1.3-7.5 PPY) with protons. Conclusion: A significant reduction in mean dose to uninvolved brain and contralateral hippocampus was found with proton planning. The estimated secondary cancer risk was reduced with proton therapy.
  •  
7.
  •  
8.
  • Edvardsson, Anneli, et al. (författare)
  • Robustness and dosimetric verification of hippocampal-sparing craniospinal pencil beam scanning proton plans for pediatric medulloblastoma
  • 2024
  • Ingår i: Physics and Imaging in Radiation Oncology. - : Elsevier. - 2405-6316. ; 29
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and PurposeHippocampal-sparing (HS) is a method that can potentially reduce late cognitive complications for pediatric medulloblastoma (MB) patients treated with craniospinal proton therapy (PT). The aim of this study was to investigate robustness and dosimetric plan verification of pencil beam scanning HS PT.Materials and MethodsHS and non-HS PT plans for the whole brain part of craniospinal treatment were created for 15 pediatric MB patients. A robust evaluation of the plans was performed. Plans were recalculated in a water phantom and measured field-by-field using an ion chamber detector at depths corresponding to the central part of hippocampi. All HS and non-HS fields were measured with the standard resolution of the detector and in addition 16 HS fields were measured with high resolution. Measured and planned dose distributions were compared using gamma evaluation.ResultsThe median mean hippocampus dose was reduced from 22.9 Gy (RBE) to 8.9 Gy (RBE), while keeping CTV V95% above 95 % for all nominal HS plans. HS plans were relatively robust regarding hippocampus mean dose, however, less robust regarding target coverage and maximum dose compared to non-HS plans. For standard resolution measurements, median pass rates were 99.7 % for HS and 99.5 % for non-HS plans (p < 0.001). For high-resolution measurements, median pass rates were 100 % in the hippocampus region and 98.2 % in the surrounding region.ConclusionsA substantial reduction of dose in the hippocampus region appeared feasible. Dosimetric accuracy of HS plans was comparable to non-HS plans and agreed well with planned dose distribution in the hippocampus region.
  •  
9.
  • Fransson, Samuel (författare)
  • Comparing multi-image and image augmentation strategies for deep learning-based prostate segmentation
  • 2024
  • Ingår i: Physics and Imaging in Radiation Oncology. - : Elsevier. - 2405-6316. ; 29
  • Tidskriftsartikel (refereegranskat)abstract
    • During MR-Linac-based adaptive radiotherapy, multiple images are acquired per patient. These can be applied in training deep learning networks to reduce annotation efforts. This study examined the advantage of using multiple versus single images for prostate treatment segmentation. Findings indicate minimal improvement in DICE and Hausdorff 95% metrics with multiple images. Maximum difference was seen for the rectum in the low data regime, training with images from five patients. Utilizing a 2D U -net resulted in DICE values of 0.80/0.83 when including 1/5 images per patient, respectively. Including more patients in training reduced the difference. Standard augmentation methods remained more effective.
  •  
10.
  • Fransson, Samuel, et al. (författare)
  • Intrafractional motion models based on principal components in Magnetic Resonance guided prostate radiotherapy
  • 2021
  • Ingår i: Physics and Imaging in Radiation Oncology. - : Elsevier. - 2405-6316. ; 20, s. 17-22
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose: Devices that combine an MR-scanner with a Linac for radiotherapy, referred to as MR-Linac systems, introduce the possibility to acquire high resolution images prior and during treatment. Hence, there is a possibility to acquire individualised learning sets for motion models for each fraction and the construction of intrafractional motion models. We investigated the feasibility for a principal component analysis (PCA) based, intrafractional motion model of the male pelvic region.Materials and methods: 4D-scans of nine healthy male volunteers were utilized, FOV covering the entire pelvic region including prostate, bladder and rectum with manual segmentation of each organ at each time frame. Deformable image registration with an optical flow algorithm was performed for each subject with the first time frame as reference. PCA was performed on a subset of the resulting displacement vector fields to construct individualised motion models evaluated on the remaining fields.Results: The registration algorithm produced accurate registration result, in general DICE overlap >0.95 across all time frames. Cumulative variance of the eigen values from the PCA showed that 50% or more of the motion is explained in the first component for all subjects. However, the size and direction for the components differed between subjects. Adding more than two components did not improve the accuracy significantly and the model was able to explain motion down to about 1 mm.onclusions: An individualised intrafractional male pelvic motion model is feasible. Geometric accuracy was about 1 mm based on 1-2 principal components.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 36
Typ av publikation
tidskriftsartikel (36)
Typ av innehåll
refereegranskat (35)
övrigt vetenskapligt/konstnärligt (1)
Författare/redaktör
Nyholm, Tufve (6)
Olsson, Caroline, 19 ... (3)
Nilsson, Per (3)
Ahnesjö, Anders, 195 ... (3)
Wieslander, Elinore (2)
Munck af Rosenschöld ... (2)
visa fler...
Nordström, Fredrik, ... (2)
Zackrisson, Björn (2)
Garpebring, Anders (2)
Kjellén, Elisabeth (2)
Ceberg, Crister (2)
Bäck, Sven (2)
Strandberg, Sara, 19 ... (2)
Riklund, Katrine, MD ... (2)
Strand, Robin, 1978- (2)
Gagliardi, G. (1)
Karlsson, Magnus (1)
Ceberg, Sofie (1)
Lempart, Michael (1)
Abel, Edvard, 1970 (1)
Björk-Eriksson, Thom ... (1)
Gustafsson, Magnus (1)
Lundberg, Peter (1)
Leonhardt, Henrik, 1 ... (1)
Bergh, Anders (1)
Adjeiwaah, Mary, 198 ... (1)
Bylund, Mikael (1)
Söderström, Karin (1)
Thellenberg Karlsson ... (1)
Adolfsson, Emelie (1)
Carlsson Tedgren, Ås ... (1)
Ahlgren, Göran (1)
Widmark, Anders (1)
Lundstedt, Dan, 1970 (1)
Karlsson, Per, 1963 (1)
Petersson, Kristoffe ... (1)
Brun, Eva (1)
Olsson, Tomas (1)
Axelsson, Jan, 1966- (1)
Szczepankiewicz, Fil ... (1)
Nilsson, Markus (1)
Karlsson, Anna (1)
Traneus, Erik (1)
Grusell, Erik (1)
Isacsson, Ulf (1)
Bergmark, Karin, 196 ... (1)
Nilsson, Mikael (1)
Lassen-Ramshad, Yasm ... (1)
Mäkitie, A (1)
Toma-Daşu, Iuliana (1)
visa färre...
Lärosäte
Lunds universitet (12)
Karolinska Institutet (9)
Göteborgs universitet (8)
Umeå universitet (8)
Uppsala universitet (8)
Linköpings universitet (2)
visa fler...
Kungliga Tekniska Högskolan (1)
Stockholms universitet (1)
visa färre...
Språk
Engelska (36)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (32)
Naturvetenskap (4)
Teknik (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy