SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Antonsson Ulf) "

Sökning: WFRF:(Antonsson Ulf)

  • Resultat 1-10 av 27
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Antonsson, Ulf, et al. (författare)
  • Funktionsprovning av tätskiktsystem för våtutrymmen 2022
  • 2022
  • Rapport (övrigt vetenskapligt/konstnärligt)abstract
    • Functional testing of waterproofing systems for use behind ceramic tiling based on flexible sheets 2022 This research project is a repetition of previously completed projects. These projects span a long period of time, 12 years. The projects were completed during the period 2010 to 2022. Functional testing The result is better than before. 2022 2019 (1) 2016 (2) 2014 (3) 2010 (4) Result Result Result Result Result Result No leakage 9 (47 %) 6 (32 %) 8 (40 %) 3 (15 %) 0 (0 %) Leakage 10 (53 %) 13 (68 %) 12 (60 %) 17 (85 %) 5 (100 %) In this investigation, most of the leaks are located to penetrations of large and small sewer pipes. In this investigation, we have on several occasions seen that the pipe sleeves have had substandard quality. This has manifested itself in the fact that the polymeric material which is to seal around the pipe during the test has lost its sealing ability. It is probable that the material has developed a residual deformation (settling) which means that the material has lost its ability to seal around the pipe. We have also noticed that pipe cuffs have delaminated, the layers in the cuff during the test have been divided into their components. Leakage has also occurred at inner corners, outer corners and at chafing. Only a few, two, leaks at connections to floor drains have been noted. Better yet, none of the examined waterproofing systems showed leaks that were so extensive that one can speak of a total damage. Water vapour resistance and mass per unit area The vast majority of investigated waterproofing foils have a water vapour resistance of between 2.5 and 4.5 million s m, which is a high or very high value. Results for five waterproofing foils fall below 2.5 million s / m. Based on the determinations of water vapor resistance and basis weight, it can be concluded that probably six of the waterproofing suppliers have developed new or changed foils since the last survey. The trend of wanting to make thinner foils seems to have been broken. Most of the waterproofing foils have a higher vapor passage resistance now than in the previous survey. It is also noteworthy that the PVC sealing layer has a low water vapor passage resistance. The waterproofing foil has basically the same basis weight now compared to the previous survey. Indication of long-term properties To obtain an indication of the amount of added antioxidants that improve the long-term properties of the materials, DSC analyses of the waterproofing foils have been performed. Compared with the previous study, the induction temperatures are at about the same level as before, only small differences occur. The average induction temperature for all polyethylene films is 216 ° C and, in summary, the materials appear to be stabilized at the same level as the previous study. In the same way as in the survey, 2016, most materials seem to be more stabilized for long-term use compared with the previous study, 2014. However, for all analysed materials, to make a reliable service life prediction of the material, a more comprehensive aging study is recommended
  •  
2.
  • Antonsson, Helena, et al. (författare)
  • Evaluation of a Web-Based Training Program for Professional Carers Working With People With Learning Disabilities and Challenging Behavior : A Pilot Study with SSED-Design
  • 2016
  • Ingår i: Issues in Mental Health Nursing. - : Informa UK Limited. - 0161-2840 .- 1096-4673. ; 37:10, s. 734-743
  • Tidskriftsartikel (refereegranskat)abstract
    • The interaction between people with intellectual disabilities and professional carers is often influenced by communicative difficulties contributing challenging behaviours. The aims of this study were to evaluate to a web-based training program aimed at improving carers' abilities to interact with people with learning disabilities who exhibit challenging behaviours and to explore carers' experiences of participating in such a program. A single-subject experimental design and mixed methods were used to integrate qualitative and quantitative data. Triangulation of questionnaires, interviews with carers, and assessments of one woman's behaviour was performed. The participants were professional carers aged 20 to 55 years. The web-based training program increased carers' abilities to handle challenging behaviours and decreased challenging behaviours in daily care. The program improved the opportunities to offer training to carers who work in community-based accommodations with limited time to receive training.
  •  
3.
  • Antonsson, Henrik, 1976, et al. (författare)
  • Nurse plant effect of the cushion plant Silene acaulis (L.) Jacq. in an alpine environment in the subarctic Scandes, Sweden
  • 2009
  • Ingår i: Plant Ecology & Diversity. - : Informa UK Limited. - 1755-0874 .- 1755-1668. ; 2:1, s. 17-25
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Facilitation plays important roles in the structuring of plant communities and several studies have found that it tends to increase with environmental severity in alpine plant communities. In addition, cushion plants have been shown to act as nurse plants, moderating extreme environmental conditions, and providing resources for other species, with substantial effects on local plant diversity. Aims: This study addresses the nurse plant effects of Silene acaulis – a common, circumpolar alpine plant species with a compact cushion-forming growth form – along an altitude transect in the mid- to high-alpine zones in northern Sweden. Methods: The numbers of species in paired S. acaulis cushions and identical-sized control plots along an altitude transect between 1150 m and 1450 m above sea level were compared, and differences in species composition were analysed. Results: At altitudes above c. 1280 m, but not at lower altitudes, more species were found inside the cushions than in their paired control plots. Species composition was similar inside cushions and in control plots. Conclusions: Our results suggest that S. acaulis acts as a nurse plant at altitudes higher than a certain threshold (c. 1280 m at the investigated site). It appears to play an important role in creating focal points for local vascular plant diversity in highalpine environments, where vegetation is open and occurs in small patches. Keywords: facilitation; plant-to-plant interactions; Silene acaulis; species richness; stress
  •  
4.
  •  
5.
  • Antonsson, Ulf, et al. (författare)
  • Bygg- och möbelskiva som tillverkas av återvunna mjölkförpackningar
  • 2022
  • Rapport (övrigt vetenskapligt/konstnärligt)abstract
    • Trenden i samhället är att öka återvinningsgrad av produkter för att skapa ytterligare värden av förbrukade produkter. Detta projekt har initierats av möjligheten att återanvända mjölkkartonger till bygg- och möbelskivor i syfte att minska byggindustrins totala miljöpåverkan genom minskat uttag av primärmaterial och lägre CO2 belastning. Förpackningsmaterial för mat och dryck innehåller ofta ett skikt av plast, av typen PET med syfte att hålla livsmedlet färskt och fritt från atmosfären. Efter användning samlas förpackningar in till förbränning då det inte finns något annat sätt att återvinna/återbruka dessa material. Det är svårt att skilja pappkartong och plast åt vid dagens förbränningsanläggningar och därmed skapas stora förorenande utsläpp (bland annat CO2). Det är önskvärt att hitta ett område där kartonger för livsmedel kan återvinnas till ett annat högvärdigt material och då kan ersätta material med högre miljöbelastning. Att göra en skiva till bygg och möbelindustrin genom att sönderdela kartonger för livsmedel och utan tillsatser pressa dem till en produkt som därmed ersätter mer belastande skivor som gips och OSB ger industrin en möjlighet att ytterligare minska sin miljöpåverkan. Ett potentiellt område kan vara inom byggindustrin, och att då hitta en ersättning eller komplement till de skivmaterial som idag används i väggar och tak. Dagens skivor är tillverkade av blandade material, i form av OSB (träspån och lim) och gips (kalk och papp). Initiala prover, genomförda av tillverkaren ej RISE, av den framtagna skivan har visat på god teknisk prestanda, men byggindustrin är på goda grunder kritisk till nya material, varför det krävs en noggrann kontroll av prestanda på såväl lång som kort sikt för att säkerställa ett kontrollerat byte till mer hållbart material. Metoden att samla in och sönderdela kartonger på ett band för press under tryck och värme, och att skapa en bygg- och möbelskiva producerad av återvunnet material utan andra tillsatser i processen är lovande. Den ingående andelen PET agerar som bindemedel för att skapa skivan som är homogen och stark. Initiala tester har visat en funktionsprestanda mellan OSB och gips, varför målsättningen är att ersätta kombinationer av dessa i flera applikationer. Introduktion av material och produkter kräver en robusthet avseende tekniska egenskaper samt tester i faktiska miljöer för introduktion i byggindustrin. Men ett ökat intresse för och krav ur miljösynpunkt öppnar för möjligheter att skapa värde. För att realisera detta värde finns det ett behov av att testa och verifiera olika tekniska egenskaper av produkten mot de funktionella krav som finns på marknaden för denna typ av produktändamål. Tekniska egenskaper som bör verifieras är bland annat formstabilitet, tålighet mot fukt, akustik, brand och avslutningsvis de miljöegenskaper som uppstår.
  •  
6.
  • Antonsson, Ulf (författare)
  • Delreparation av tätskiktssystem : del 1    Pilotundersökningar i labb
  • 2020
  • Rapport (övrigt vetenskapligt/konstnärligt)abstract
    •  Pilot surveys in labs This project is the first part of an intended major project to verify methods for partial repairs and methods for quality assurance of these repairs. This part of the project is implemented in order to make the next part of the project (Part 2. Field study) credible and valid. The purpose is to investigate whether selected measurement systems are capable of warning of excess moisture where leakage occurs so that there is no consequential damage to the building. The aim of this part is to evaluate and build knowledge about how sensors should be used and the possibility to interpret results from these. The study of the function of the warning systems for moisture and water damage that will be used in the future field study has been carried out in a mock-up that has been developed within the project. The project has been carried out with five different moisture sensor systems. During the entire test period, RISE have carried out measurements of temperature and moisture level in the test set’s timber framework compartments. Measured values from the five moisture sensor systems have been compared to values from RISE's calibrated temperature and humidity sensors. The surveys carried out can be grouped as follows: • Function control of the moisture system's ability to detect elevated moisture levels in each mock-up’s framework. • Loading of undamaged floor and wall penetrations with water  • Loading of pre-damaged floor and wall penetrations with water  • Loading of partially repaired floor and wall penetrations with water  Function control Moisture sensor systems 2, 3, 4 and 5 show a relatively good compliance with RISE's calibrated moisture and temperature sensors, usually only a few percentage points deviation is noted. Note that the test procedure selected is not relevant for Invisense’s moisture sensor system (system 1) as these are located in different positions than the other moisture sensor systems. Loading of undamaged floor and wall penetrations with water  Floor When loading the floors with water, leakage was noted in test space 1 already after two hours of loading. This was recorded by the moisture sensors located in test compartment 1. Wall Already a few minutes after commencement of water spraying, a rising moisture level was observed and also recorded by the moisture sensors in test compartment 3. It is worth noting that this leakage was so small that no free water was detected. An increase in moisture level was recorded at the wall penetrations in test compartment 4 after about 10 hours. At the end of the spraying cycle the moisture sensor sample in compartment 1 also showed a raised value. Loading of pre-damaged floor and wall penetrations with water  Floor All of the floor drains were subjected to pre-test damage, which consisted in removal of the clamping ring, cutting of the collar in one place and splitting it open a few centimetres. All moisture sensor systems used in the floor wells in test compartments 1-4 indicated elevated values. Wall Pre-test damage to all wall penetrations was carried out using an awl that was pressed into the space between the tile and wall box and thus puncturing the sealing collar. All moisture sensor systems used in the wall penetrations in test compartments 1-4 indicated elevated values. Loading of partially repaired floor and wall penetrations with water  Floor After partial repair where all floor drains were replaced, water loading of the floor was again carried out with 100 mm water.  No leakage was detected during the 5-day water load. None of the moisture sensor systems indicated any leakage. Wall After the partial repair where all pipe collars were replaced, water spraying took place again with alternating cold and warm water (1500 times).  No leakage was detected. None of the moisture sensor systems indicated any leakage.Conclusion • All moisture sensor systems in the study have the capability to show that leakage has occurred • It is not the absolute measured value of the moisture level that determines whether the waterproofing system is leaking or not  It is the change in the moisture level in the construction itself that is crucial to the question as to whether it is to be opened up or not.
  •  
7.
  • Antonsson, Ulf (författare)
  • Delreparation av tätskiktssystem – del 2 - Fältundersökning
  • 2022
  • Rapport (övrigt vetenskapligt/konstnärligt)abstract
    • Partial repair of waterproofing systems – Part 2 - Field survey This research project has been terminated prematurely at the request of the funder. The decision to terminate was made as the project has not received suitable objects to the extent required for the project to be carried out as it was planned and promised in the application. It has been unexpectedly difficult to get suitable objects for the project. The idea was that the insurance companies represented in the project team would provide the project with suitable objects. Only four objects have been received for the project. In these objects, humidity sensors have been deployed and measurements have begun. With the Invisense system, only starting measurements to be used as a reference to the next measurement have been carried out. This means that there are no trends to ana-lyse. For the other measurement systems (iioote and Talkpool), the measurements have been ongoing for about six and nine months respectively. In some of the objects, the measurements do not start after installation. It is likely that the sensors do not have contact with the internet via the LoRaWAN technology used. At the objects where measurements start, the moisture level appears to be at a normal level, there does not seem to be any leakage.
  •  
8.
  • Antonsson, Ulf, et al. (författare)
  • Funktionsprovning av tätskiktsystem för våtutrymmen 2016
  • 2016
  • Rapport (övrigt vetenskapligt/konstnärligt)abstract
    • Detta är andra gången ett forskningsprojekt av denna typ genomförs och syftet och målet är att kunna visa på tätskiktssystem som har god prognos att uppfylla kravet på vattentäthet och därmed vara vattenskadesäkrande. Ett annat syfte har varit att se om tillverkarna har tagit till sig av resultaten från den tidigare utförda undersökningen som rapporterades 2014 i SP Rapport 2014:45.
  •  
9.
  • Antonsson, Ulf, et al. (författare)
  • Funktionsprovning av tätskiktsystem förvåtutrymmen 2019
  • 2018
  • Rapport (refereegranskat)abstract
    • Functional testing of waterproofing systems for use behind ceramic tiling based on flexible sheets 2019Functional testingThe result is worse than before.Six (32%) of the nineteen tested waterproofing systems passed the function test without leakage. Thirteen (68%) tests resulted in leakage.This result is worse than that obtained in the previous project in 2016, (1) when eight (40%) of twenty tested waterproofing systems passed the functional test without leakage. There has therefore been some deterioration in the as constructed systems.The result, however, is better than in the project performed in 2014 (2) when only three (15%) of twenty tested waterproofing systems passed without leakage.In this project, several leakages are localised around the penetrations of large and small drainpipes. This is an increase compared to previous studies. We have seen on several occasions that pipe collars have had poor quality. This has been noticed by that the polymer material used for sealing around the tube has lost its water tightness ability during the test. It is most probable that the material has a residual deformation (from setting) that causes the material to lose its ability to seal around the tube. We have also noted that the pipe collars have delaminated i.e. the layers in the collars have been divided into their individual constituents during the test.Leakages have also been caused by connections to gullies, inside corners, outside corners and in joints of foils.Fortunately, none of the investigative systems showed leakage that was so extensive that one could describe it as total damage.Water vapour resistance and mass per unit areaThirteen tested waterproofing on flexible sheet systems show a result between 2,5 and 4,5 million s/m, which is a high or very-high water vapour resistance. Six flexible sheet systems have a result below 2,5 million s/m.In the determination of water vapour resistance and mass per unit area, we can clearly see that some manufacturers have made changes in or replaced their flexible sheet with a new one, compared with the previous investigation (1).We further note that 10 out of 14 flexible sheets have a lower water vapor resistance than in the previous investigation (1). It is also notable that the PVC sealing layer has a low water vapor resistance.Indication of long-term propertiesIn order to obtain an indication of the amount added antioxidants that improves the long-term properties of the materials, the DSC analysis of flexible sheets have been performed. In the same way as in the previous project, 2016, (1) it seems that the flexible sheets to be more stabilized for long-term use compared to the previous study in 2014, (2). However, for all analysed materials, to make a reliable service life prediction of the material, an accelerated ageing at moderate temperature is recommended.
  •  
10.
  • Antonsson, Ulf (författare)
  • Lufttäta klimatskal under verkligaförhållanden
  • 2017
  • Rapport (refereegranskat)abstract
    • Beständigheten hos klimatskalets lufttäthetsystem är helt avgörande för om näranollenergihus, passivhus och plushus kommer att fungera som det var tänkt över tid. Eftersom produkterna som säkerställer lufttätheten oftast befinner sig inuti konstruktionen kan det därför innebära stora ingrepp i byggnader om de behöver bytas ut i förtid. Att i laboratorium i förväg kunna utvärdera beständigheten hos det lufttätande systemet är viktigt och för detta behövs en provningsmetod.Det överordnade syftet med hela projektet är att utveckla en metod där hela system för lufttäthet kan undersökas. Detta så att god lufttäthet och låg energianvändning kan erhållas under lång tid hos framtidens lufttäthetssystem. Denna etapp av projektet har innehållit utveckling och provkörning av en ny provningsmetod. Provningsmetodiken har dokumenterats i SP-metod 5264, utgåva 2, bilaga 2 till denna rapport. Provningsmetoden har fungerat ypperligt vid pilotprovningarna. Man ser en förändring av lufttätheten vid mätningar före respektive efter värmebehandlingen. Provningsmetoden är mycket noggrann och känslig på så sätt att förändring i lufttätheten kan registreras.Provningsmetoden är ett mycket bra verktyg för producenter av lufttäthetssystem vid produktutveckling. Metoden är också lämplig för användning vid utvärdering av lufttäthetssystem för olika godkännandesystem och certifiering. Samtliga provade lufttäthetssystem var mycket lufttäta före värmebehandlingen. Alla systemen visar på resultat under 0,1 l/(s∙m²). Efter värmebehandlingen visar alla undersökta lufttäthetssystem dock en ökande luftgenomsläpplighet, i varierande grad.I projektet har även montage av lufttäthetssystem gjorts i miljöer som valts för att efterlikna realistiska byggarbetsplatsförhållanden. Alla de undersökta lufttäthetssystemen visar på förändringar i lufttätheten då montaget har skett i kall och fuktig miljö och vid montage i dammig miljö. Variationen mellan de olika systemen har dock varit ganska stor.Det är vår uppfattning om alla lufttäthetsystem i framtiden undersöks med hjälp av denna provningsmetod så kommer man att få en stark förbättring av lufttätheten och därmed lägre energianvändning..
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 27
Typ av publikation
rapport (16)
tidskriftsartikel (10)
konferensbidrag (1)
Typ av innehåll
refereegranskat (14)
övrigt vetenskapligt/konstnärligt (13)
Författare/redaktör
Antonsson, Ulf (14)
Karlsson, Ulf (3)
Gisslén, Magnus, 196 ... (3)
Hammarlund-Udenaes, ... (3)
Antonsson, Liselotte (3)
Nordling, Bengt (3)
visa fler...
Demker, Ingvar (3)
Molau, Ulf, 1951 (2)
Esbjörnsson, Joakim (2)
Lindahl, Ulf (2)
Larsson, Maria (2)
Medstrand, Patrik (2)
Andreasson, Fredrik (2)
Björk, Robert G., 19 ... (2)
Antonsson, Anna (2)
Antonsson, Henrik, 1 ... (2)
Samuelson, Ingemar (2)
Sjöqvist, Mia (2)
Jansson, Anders (1)
Hagberg, Lars, 1951 (1)
Svennerholm, Bo, 194 ... (1)
Kåredal, Monica (1)
Gustavsson, Börje (1)
Nilsson, Bengt (1)
Jansson, Anna (1)
Winiwarter, Susanne (1)
Olofsson, Mikael (1)
Edwards, Ylva (1)
Albin, Maria (1)
Nielsen, Jörn (1)
Gustavsson, Per (1)
Tinnerberg, Håkan, 1 ... (1)
Sabirsh, Alan (1)
Johansson, Roger (1)
Strandberg, Bo, 1960 (1)
Antonsson, Ann-Beth (1)
Åström, Sture (1)
Xu, YiYi (1)
Williams Portal, Nat ... (1)
Gerdin, Bengt (1)
Trägårdh, Jan (1)
Antonsson, Helena (1)
Hällgren Graneheim, ... (1)
Isaksson, Ulf (1)
Lundström, Mats O. (1)
Antonsson, J (1)
Owman, Christer (1)
Bok, Gunilla (1)
Peltoperä, Janne (1)
Berntsson, Ulf (1)
visa färre...
Lärosäte
RISE (14)
Göteborgs universitet (6)
Uppsala universitet (4)
Lunds universitet (4)
Karolinska Institutet (4)
Naturvårdsverket (2)
visa fler...
Umeå universitet (1)
Högskolan Väst (1)
IVL Svenska Miljöinstitutet (1)
visa färre...
Språk
Svenska (16)
Engelska (11)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (8)
Teknik (6)
Naturvetenskap (4)
Lantbruksvetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy