SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Fix A.) "

Sökning: WFRF:(Fix A.)

  • Resultat 1-8 av 8
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Aguar-Bartolome, P., et al. (författare)
  • New determination of the eta transition form factor in the Dalitz decay eta -> e(+) e(-) gamma with the Crystal Ball/TAPS detectors at the Mainz Microtron
  • 2014
  • Ingår i: Physical Review C (Nuclear Physics). - 0556-2813. ; 89:4
  • Tidskriftsartikel (refereegranskat)abstract
    • The Dalitz decay eta -> e(+) e(-) gamma has been measured in the gamma p -> eta p reaction with the Crystal Ball and TAPS multiphoton spectrometers, together with the photon-tagging facility at the Mainz Microtron MAMI. The experimental statistic used in this work is one order of magnitude greater than in any previous measurement of eta -> e(+) e(-) gamma. The value obtained for the slope parameter Lambda(-2) of the eta transition form factor, Lambda(-2) = (1.95 +/- 0.15(stat) +/- 0.10(syst)) GeV-2, is in good agreement with recent measurements conducted in eta -> e(+) e(-) gamma and eta -> mu(+) mu(-) gamma decays, as well as with recent form-factor calculations. The uncertainty obtained in the value of Lambda(-2) is lower compared to results from previous measurements of the eta -> e(+) e(-) gamma decay.
  •  
2.
  • Aguar-Bartolome, P., et al. (författare)
  • Measurement of the gamma p -> K-0 Sigma(+) reaction with the Crystal Ball/TAPS detectors at the Mainz Microtron
  • 2013
  • Ingår i: Physical Review C (Nuclear Physics). - 0556-2813. ; 88:4
  • Tidskriftsartikel (refereegranskat)abstract
    • The gamma p -> K-0 Sigma(+) reaction has been measured from threshold to E-gamma = 1.45 GeV (W-CM = 1.9 GeV) using the Crystal Ball and TAPS multiphoton spectrometers together with the photon tagging facility at the Mainz Microtron MAMI. In the present experiment, this reaction was searched for in the 3 pi(0)p final state, by assuming K-S(0) -> pi(0)pi(0) and Sigma(+) -> pi(0)p. The experimental results include total and differential cross sections as well as the polarization of the recoil hyperon. The new data significantly improve empirical knowledge about the gamma p -> K-0 Sigma(+) reaction in the measured energy range. The results are compared to previous measurements and model predictions. It is demonstrated that adding the present gamma p -> K-0 Sigma(+) results to existing data allowed a better description of this reaction with various models.
  •  
3.
  • Kashevarov, V. L., et al. (författare)
  • Experimental study of the gamma p -> pi (0)pi(0) p reaction with the Crystal Ball/TAPS detector system at the Mainz Microtron
  • 2012
  • Ingår i: Physical Review C (Nuclear Physics). - 0556-2813. ; 85:6
  • Tidskriftsartikel (refereegranskat)abstract
    • The gamma p -> pi(0)pi(0) p reaction has been measured from threshold to 1.4 GeV using the Crystal Ball and TAPS photon spectrometers together with the photon tagging facility at the Mainz Microtron. The experimental results include total and differential cross sections as well as specific angular distributions, which were used to extract partial-wave amplitudes. In particular, the energy region below the D-13(1520) resonance was studied.
  •  
4.
  • Akhtar, M., et al. (författare)
  • Evaluation of the safety and immunogenicity of the oral inactivated multivalent enterotoxigenic Escherichia coli vaccine ETVAX in Bangladeshi adults in a double-blind, randomized, placebo-controlled Phase I trial using electrochemiluminescence and ELISA assays for immunogenicity analyses
  • 2019
  • Ingår i: Vaccine. - : Elsevier BV. - 0264-410X. ; 37:37, s. 5645-5656
  • Tidskriftsartikel (refereegranskat)abstract
    • The safety and immunogenicity of the second generation oral enterotoxigenic Escherichia coli (ETEC) vaccine ETVAX, consisting of inactivated recombinant E. coli strains over-expressing the colonization factors (CFs) CFA/I, CS3, CS5 and CS6 and the heat labile toxoid LCTBA, were evaluated in Bangladeshi volunteers. To enable analysis of antibody responses against multiple vaccine antigens for subsequent use in small sample volumes from children, a sensitive electrochemiluminescence (ECL) assay for analysis of intestine-derived antibody-secreting cell responses using the antibodies in lymphocyte secretions (ALS) assay was established using Meso Scale Discovery technology. Three groups of Bangladeshi adults (n = 15 per group) received two oral doses of ETVAX with or without double mutant LT (dmLT) adjuvant or placebo in the initial part of a randomized, double-blind, placebo-controlled, age-descending, dose-escalation trial. CF- and LTB-specific ALS and plasma IgA responses were analyzed by ECL and/or ELISA. ETVAX was safe and well tolerated in the adults. Magnitudes of IgA ALS responses determined by ECL and ELISA correlated well (r = 0.85 to 0.98 for the five primary antigens, P < 0.001) and ECL was selected as the ALS readout method. ALS IgA responses against each of the primary antigens were detected in 87-100% of vaccinees after the first and in 100% after the second vaccine dose. Plasma IgA responses against different CFs and LTB were observed in 62-93% and 100% of vaccinees, respectively. No statistically significant adjuvant effect of dmLT on antibody responses to any antigen was detected, but the overall anti-genic breadth of the plasma IgA response tended to favor the adjuvanted vaccine when responses to 4 or more or 5 vaccine antigens were considered. Responses in placebo recipients were infrequent and mainly detected against single antigens. The promising results in adults supported testing ETVAX in descending age groups of children.
  •  
5.
  • Qadri, F., et al. (författare)
  • Safety and immunogenicity of the oral, inactivated, enterotoxigenic Escherichia coli vaccine ETVAX in Bangladeshi children and infants: a double-blind, randomised, placebo-controlled phase 1/2 trial
  • 2020
  • Ingår i: Lancet Infectious Diseases. - : Elsevier BV. - 1473-3099. ; 20:2, s. 208-219
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Enterotoxigenic Escherichia coil causes diarrhoea, leading to substantial mortality and morbidity in children, but no specific vaccine exists. This trial tested an oral, inactivated, enterotoxigenic E coli vaccine (ETVAX), which has been previously shown to be safe and highly immuongenic in Swedish and Bangladeshi adults. We tested the safety and immunogenicity of ETVAX, consisting of four E coli strains overexpressing the most prevalent colonisation factors (CFA/I, CS3, CSS, and CS6) and a toxoid (LCTBA) administered with or without a double-mutant heat-labile enterotoxin (dmLT) as an adjuvant, in Bangladeshi children. Methods We did a randomised, double-blind, placebo-controlled, dose-escalation, age-descending, phase 1/2 trial in Dhaka, Bangladesh. Healthy children in one of three age groups (24-59 months, 12-23 months, and 6-11 months) were eligible. Children were randomly assigned with block randomisation to receive either ETVAX, with or without dmLT, or placebo. ETVAX (half [5.5 x 10(10) cells], quarter [2.5 x 10(10) cells], or eighth [1.25 x 10(10) cells] adult dose), with or without dmLT adjuvant (2.5 mu g, 5.0 mu g, or 10.0 mu g), or placebo were administered orally in two doses 2 weeks apart. Investigators and participants were masked to treatment allocation. The primary endpoint was safety and tolerability, assessed in all children who received at least one dose of vaccine. Antibody responses to vaccine antigens, defined as at least a two-times increase in antibody levels between baseline and post-immunisation, were assessed as secondary endpoints. This trial is registered with ClinicalTrials.gov , NCT02531802. Findings Between Dec 7, 2015, and Jan 10, 2017, we screened 1500 children across the three age groups, of whom 430 were enrolled and randomly assigned to the different treatment groups (130 aged 24-59 months, 100 aged 12-23 months, and 200 aged 6-11 months). All participants received at least one dose of vaccine. No solicited adverse events occurred that were greater than moderate in severity, and most were mild. The most common solicited event was vomiting (ten [8%] of 130 patients aged 24-59 months, 13 [13%] of 100 aged 12-23 months, and 29 115%1 of 200 aged 6-11 months; mostly of mild severity), which appeared related to dose and age. The addition of dmLT did not modify the safety profile. Three serious adverse events occurred but they were not considered related to the study drug. Mucosal IgA antibody responses in lymphocyte secretions were detected against all primary vaccine antigens (CFA/I, CS3, CSS, CS6, and the LCTBA toxoid) in most participants in the two older age groups, whereas such responses to four of the five antigens were less frequent and of lower magnitude in infants aged 6-11 months than in older children. Faecal secretory IgA immune responses were recorded against all vaccine antigens in infants aged 6-11 months. 78 (56%) of 139 infants aged 6-11 months who were vaccinated developed mucosal responses against at least three of the vaccine antigens versus 14 (29%) of 49 of the infants given placebo. Addition of the adjuvant dmLT enhanced the magnitude, breadth, and kinetics (based on number of responders after the first dose of vaccine) of immune responses in infants. Interpretation The encouraging safety and immunogenicity of ETVAX and benefit of dmLT adjuvant in young children support its further assessment for protective efficacy in children in enterotoxigenic E coli-endemic areas. Copyright (C) 2019 The Author(s). Published by Elsevier Ltd.
  •  
6.
  • Wetzel, G., et al. (författare)
  • Validation of MIPAS-ENVISAT H2O operational data collected between July 2002 and March 2004
  • 2013
  • Ingår i: Atmospheric Chemistry And Physics. - : Copernicus GmbH. - 1680-7316 .- 1680-7324. ; 13:11, s. 5791-5811
  • Tidskriftsartikel (refereegranskat)abstract
    • Water vapour (H2O) is one of the operationally retrieved key species of the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) instrument aboard the Environmental Satellite (ENVISAT) which was launched into its sun-synchronous orbit on 1 March 2002 and operated until April 2012. Within the MIPAS validation activities, independent observations from balloons, aircraft, satellites, and ground-based stations have been compared to European Space Agency (ESA) version 4.61 operational H2O data comprising the time period from July 2002 until March 2004 where MIPAS measured with full spectral resolution. No significant bias in the MIPAS H2O data is seen in the lower stratosphere (above the hygropause) between about 15 and 30 km. Differences of H2O quantities observed by MIPAS and the validation instruments are mostly well within the combined total errors in this altitude region. In the upper stratosphere (above about 30 km), a tendency towards a small positive bias (up to about 10 %) is present in the MIPAS data when compared to its balloon-borne counterpart MIPAS-B, to the satellite instruments HALOE (Halogen Occultation Experiment) and ACE-FTS (Atmospheric Chemistry Experiment, Fourier Transform Spectrometer), and to the millimeter-wave airborne sensor AMSOS (Airborne Microwave Stratospheric Observing System). In the mesosphere the situation is unclear due to the occurrence of different biases when comparing HALOE and ACE-FTS data. Pronounced deviations between MIPAS and the correlative instruments occur in the lowermost stratosphere and upper troposphere, a region where retrievals of H2O are most challenging. Altogether it can be concluded that MIPAS H2O profiles yield valuable information on the vertical distribution of H2O in the stratosphere with an overall accuracy of about 10 to 30% and a precision of typically 5 to 15% - well within the predicted error budget, showing that these global and continuous data are very valuable for scientific studies. However, in the region around the tropopause retrieved MIPAS H2O profiles are less reliable, suffering from a number of obstacles such as retrieval boundary and cloud effects, sharp vertical discontinuities, and frequent horizontal gradients in both temperature and H2O volume mixing ratio (VMR). Some profiles are characterized by retrieval instabilities.
  •  
7.
  •  
8.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-8 av 8

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy