SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Flivik Gunnar) "

Sökning: WFRF:(Flivik Gunnar)

  • Resultat 1-10 av 53
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Kiernan, Sverrir, et al. (författare)
  • Unexpected varus deformity and concomitant metal ion release and MRI findings of modular-neck hip stems : descriptive RSA study in 75 hips with 8 years’ follow-up
  • 2021
  • Ingår i: Acta Orthopaedica. - : Medical Journals Sweden AB. - 1745-3674 .- 1745-3682. ; 92:1, s. 67-73
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose — Modular-neck hip stems have been identified with corrosion-related problems from the neck–stem junction. We report an ongoing varus deformity of modular-neck hip stems with simultaneous metal ion release observed during a study comparing the migration of modular vs. standard hip stems. Patients and methods — We followed 50 patients with modular and 25 with standard neck stems using radiostereometry (RSA). At 5-year follow-up, we noted a compromised integrity of the modular stem with varus deformity in the neck–stem interface. Changes in head–tip distance as well as whole-blood ion concentration and MRI findings were analyzed. The modular stems were followed further up to 8 years. Results — The head–tip distance decreased continuously by 0.15 mm per year resulting in 1.2 (95% CI 1.0–1.4) mm at 8 years for modular stems, while for the standard stems at 5 years, the decrease was 0.09 (CI 0.0–0.2) mm or 0.02 mm/year. For the modular stems, the reduction in head–tip distance correlated to the increase in whole-blood cobalt concentration at 8 years but not to the MRI grading of tissue reactions. At 5 years, cobalt levels were 4.9 µg/L for modular stems and at 8 years 4.8 µg/L, whereas for standard stems this was 1.0 µg/L. After 8 years, 9 of 72 stems had been revised for different reasons, but only 1 with obvious adverse local tissue reaction (ALTR). Interpretation — We present a surprisingly large progressive deformation at the modular neck–stem junction, but so far without a definite clinical problem. Even the femoral head seems to show slight compression onto the taper over time. A high rate of revisions for the modular type of this stem has raised general concerns, and it has been recalled from the market.
  •  
2.
  • Weber, Erik, et al. (författare)
  • Migration pattern of a short uncemented stem with or without collar : a randomised RSA-study with 2 years follow-up
  • 2021
  • Ingår i: HIP International. - : SAGE Publications. - 1120-7000 .- 1724-6067. ; 31:4, s. 500-506
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: There is an increasing interest in shorter, proximally loading, uncemented femoral stems. The aim of this study was to evaluate a new short stem type, its design based on a well-proven precursor, but with several new design features to facilitate easier insertion and possible preservation of proximal bone stock. It is available with or without a collar. Methods: The study includes 50 patients with primary osteoarthritis, mean age 59 (range 36–75) years, randomised to receive either the collar-fitted or the collarless stem. The patients underwent repeated radiostereometry (RSA) examinations (0, 0.5, 3, 12, 24 months), conventional radiography and filled out both hip-specific (HOOS) and general health (EQ-5D) questionnaires. Results: There was no statistically significant difference between the collared and collarless stems regarding migration and clinical outcome. Both stem types exhibit a similar pattern of initial subsidence (collared 0.63 mm vs. collarless 0.75 mm [p = 0.50]) and retroversion (collared 0.71° vs. collarless 0.97° [p = 0.36]) up to 3 months followed by stabilisation, in similarity with its precursors, suggesting good osseointegration. No stem has been revised or considered loose. Conclusions: The new design features, including shortening the stem, do not compromise migration pattern or osseointegration, regardless collar or not.
  •  
3.
  • Abdulghani, Saba, et al. (författare)
  • The influence of initial pressurization and cup introduction time on the depth of cement penetration in an acetabular model.
  • 2007
  • Ingår i: Acta Orthopaedica. - : Medical Journals Sweden AB. - 1745-3682 .- 1745-3674. ; 78:3, s. 333-339
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Acetabular cementation during total hip arthroplasty is considered difficult mainly due to the appearance and anatomy of the acetabulum. Improved cementation technique has been shown to improve the longevity of acetabular components. Method We designed a ceramic model to investigate the effect of varying the initial cement pressurization and cup introduction times on the depth of cement penetration. 4 groups were prepared, 2 of which involved varying initial cement pressurization and cup introduction times. Group 3 involved initial cement pressurization with no cup introduction, while group 4 involved cup introduction with no prior cement pressurization. Results and interpretation Most cement penetration occurred in the early pressurization phase, and we conclude that a relatively early and longer cement pressurization time and late cup introduction are positive factors for increased cement penetration in the acetabulum model.
  •  
4.
  • Ali, Abdulemir, et al. (författare)
  • Doubtful effect of continuous intraarticular analgesia after total knee arthroplasty.
  • 2015
  • Ingår i: Acta Orthopaedica. - : Medical Journals Sweden AB. - 1745-3682 .- 1745-3674. ; 86:3, s. 373-377
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose - Local infiltration analgesia (LIA) is well established for effective postoperative pain relief in total knee arthroplasty (TKA). To prolong the effect of LIA, infusion pumps with local intraarticular analgesia can be used. We evaluated the effect of such an infusion pump for the first 48 h postoperatively regarding pain, knee function, length of stay (LOS) in hospital, and complications. Patients and methods - 200 patients received peroperative LIA and a continuous intraarticular elastomeric infusion pump set at 2 mL/h. The patients were randomized either to ropivacaine (7.5 mg/mL) or to NaCl (9 mg/mL) in the pump. Visual analog scale (VAS) pain (0-100 mm), analgesic consumption, side effects of medicine, range of motion (ROM), leg-raising ability, LOS, and complications during the first 3 months were recorded. Results - On the first postoperative day, the ropivacaine group had lower VAS pain (33 vs. 40 at 12 noon and 36 vs. 43 at 8 p.m.; p = 0.02 and 0.03, respectively), but after that all recorded variables were similar between the groups. During the first 3 months, the ropivacaine group had a greater number of superficial and deep surgical wound infections (11 patients vs. 2 patients, p = 0.02). There were no other statistically significant differences between the groups. Interpretation - Continuous intraarticular analgesia (CIAA) with ropivacaine after TKA has no relevant clinical effect on VAS pain and does not affect LOS, analgesic consumption, ROM, or leg-raising ability. There may, however, be a higher risk of wound-healing complications including deep infections.
  •  
5.
  • Ali, Abdulemir, et al. (författare)
  • Preoperative Anxiety and Depression Correlate With Dissatisfaction After Total Knee Arthroplasty : A Prospective Longitudinal Cohort Study of 186 Patients, With 4-Year Follow-Up
  • 2017
  • Ingår i: Journal of Arthroplasty. - : Elsevier BV. - 0883-5403. ; 32:3, s. 767-770
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: After more than 4 decades experience of total knee arthroplasty (TKA), there is still a group of patients who are not satisfied with the outcome. In spite of the improvement of many aspects around the procedure, for unexplainable reasons, patient dissatisfaction is still approximately the same. We conducted this study to analyze correlations between preoperative psychological aspects and dissatisfaction after TKA.METHODS: A total of 186 patients were operated with a primary TKA. Patients filled out the Hospital Anxiety and Depression Scale, Visual Analog Pain Scale (0-100), and Knee injury and Osteoarthritis Outcome Score preoperatively and 4 years postoperatively. Four years postoperatively, the patients also scored their satisfaction degree with the outcome of the surgery.RESULTS: Of 186 patients, 27 (15%) reported that they were dissatisfied or uncertain with the result of their TKA 4 years postoperatively. Sixteen of those 27 patients had reported anxiety/depression preoperatively compared with 11 of 159 (7%) in the satisfied or very satisfied groups. Patients with preoperative anxiety or depression had more than 6 times higher risk to be dissatisfied compared with patients with no anxiety or depression (P < .001). Patients with deep prosthetic infection had 3 times higher risk to be dissatisfied with the operation outcome (P = .03). Dissatisfied patients had 1-day longer hospital stay compared with the satisfied group (P < .001).CONCLUSION: Preoperative anxiety and/or depression is an import predictor for dissatisfaction after TKA. Psychological assessment and treatment preoperatively might improve degree of satisfaction.
  •  
6.
  • Andersen, Mikkel Rathsach, et al. (författare)
  • Monoblock versus modular polyethylene insert in uncemented total knee arthroplasty : A randomized RSA study with 2-year follow-up of 53 patients
  • 2016
  • Ingår i: Acta Orthopaedica. - : Medical Journals Sweden AB. - 1745-3674 .- 1745-3682. ; 87:6, s. 607-614
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose — Backside wear of the polyethylene insert in total knee arthroplasty (TKA) can produce clinically significant levels of polyethylene debris, which can lead to loosening of the tibial component. Loosening due to polyethylene debris could theoretically be reduced in tibial components of monoblock polyethylene design, as there is no backside wear. We investigated the effect of 2 different tibial component designs, monoblock and modular polyethylene, on migration of the tibial component in uncemented TKA. Patients and methods — In this randomized study, 53 patients (mean age 61 years), 32 in the monoblock group and 33 in the modular group, were followed for 2 years. Radiostereometric analysis (RSA) was done postoperatively after weight bearing and after 3, 6, 12, and 24 months. The primary endpoint of the study was comparison of the tibial component migration (expressed as maximum total point motion (MTPM)) of the 2 different implant designs. Results — We did not find any statistically significant difference in MTPM between the groups at 3 months (p = 0.2) or at 6 months (p = 0.1), but at 12 and 24 months of follow-up there was a significant difference in MTPM of 0.36 mm (p = 0.02) and 0.42 mm (p = 0.02) between groups, with the highest amount of migration (1.0 mm) in the modular group. The difference in continuous migration (MTPM from 12 and 24 months) between the groups was 0.096 mm (p = 0.5), and when comparing MTPM from 3–24 months, the difference between the groups was 0.23 mm (p = 0.07). Interpretation — In both study groups, we found the early migration pattern expected, with a relatively high initial amount of migration from operation to 3 months of follow-up, followed by stabilization of the implant with little migration thereafter. However, the modular implants had a statistically significantly higher degree of migration compared to the monoblock. We believe that the greater stiffness of the modular implants was the main reason for the difference in migration, but an initial creep in the polyethylene metal-back locking mechanism of the modular group could also be a possible explanation for the observed difference in migration between the 2 study groups.
  •  
7.
  • Andersen, Mikkel Rathsach, et al. (författare)
  • Tibial Component Undersizing Is Related to High Degrees of Implant Migration Following Cementless Total Knee Arthroplasty : A Study of Radiostereometric Analysis Data for 111 Patients with 2-Year Follow-up
  • 2023
  • Ingår i: JBJS Open Access. - 2472-7245. ; 8:3
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Radiostereometric analysis (RSA) studies have shown that the continuous migration of tibial components is predictive of aseptic loosening following total knee arthroplasty (TKA). In the present study, we investigated whether accurate sizing and placement of tibial components are related to the degree of implant migration as measured with use of RSA.Methods:A total of 111 patients who underwent TKA surgery with a cementless tibial component were followed for a period of 2 years postoperatively, during which implant migration was assessed with use of RSA. RSA was performed within 7 days postoperatively and after 3, 6, 12, and 24 months. Postoperative radiographs were evaluated for component size and placement in the tibia. The evaluations were performed by experienced knee surgeons who were blinded to the migration data and clinical outcomes. A multivariable linear regression analysis was conducted.Results:Continuous implant migration (i.e., migration occurring between 12 and 24 months postoperatively) had a negative association with tibial component size (coefficient [B], -0.2; 95% confidence interval [CI], -0.33 to -0.08). Subsidence was associated with the absence of posterior cortical bone support (B, -0.7; 95% CI, -1.09 to -0.28), the absence of lateral cortical bone support (B, 0.8; 95% CI, 0.29 to 1.37), frontal-plane varus malalignment (B, 0.6; 95% CI, 0.12 to 1.16), and component undersizing (B, -0.4; 95% CI, -0.06 to -0.68). Posterior tilt was associated only with undersizing (B, 0.6; 95% CI, 0.27 to 1.11).Conclusions:Undersized cementless tibial components are at a higher risk for poor fixation with continuous migration following TKA. Therefore, a higher risk of aseptic loosening should be expected.Level of Evidence:Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
  •  
8.
  • Belfrage, Ola, et al. (författare)
  • Local treatment of cancellous bone grafts with BMP-7 and zoledronate increases both the bone formation rate and bone density.
  • 2011
  • Ingår i: Acta Orthopaedica. - : Medical Journals Sweden AB. - 1745-3682 .- 1745-3674. ; 82:2, s. 228-233
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose The remodeling of morselized bone grafts in revision surgery can be enhanced by an anabolic substance such as a bone morphogenetic protein (BMP). On the other hand, BMPs boost catabolism and might cause a premature resorption, both of the graft and of the new-formed bone. Bisphosphonates inactivate osteoclasts and can be used to control the resorption. We studied a combination of both drugs as a local admix to a cancellous allograft. Methods Cancellous bone allografts were harvested and freeze-dried. Either saline, BMP-7, the bisphosphonate zoledronate, or a combination of BMP-7 and zoledronate were added in solution. The grafts were placed in bone conduction chambers and implanted in the proximal tibia of 34 rats. The grafts were harvested after 6 weeks and evaluated by histomorphometry. Results Bone volume/total volume (BV/TV) was 50% in the grafts treated with the combination of BMP-7 and zoledronate and 16% in the saline controls (p < 0.001). In the zoledronate group BV/TV was 56%, and in the BMP group it was 14%. The ingrowth distance of new bone into the graft was 3.5 mm for the combination of BMP-7 and zoledronate and 2.6 mm in the saline control (p = 0.002). The net amount of retained remodeled bone was more than 4 times higher when BMP-7 and zoledronate were combined than in the controls. Interpretation An anabolic drug like BMP-7 can be combined with an anti-catabolic bisphosphonate as local bone graft adjunct, and the combination increases the amount of remaining bone after remodeling is complete.
  •  
9.
  • Belfrage, Ola, et al. (författare)
  • Locally administered bisphosphonate in hip stem revisions using the bone impaction grafting technique : a randomised, placebo-controlled study with DXA and five-year RSA follow-up
  • 2019
  • Ingår i: HIP International. - : SAGE Publications. - 1120-7000 .- 1724-6067. ; 29:1, s. 26-34
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Bisphosphonates have previously been shown to increase the density of impacted graft bone. In the present study we hypothesise that bisphosphonates also reduce early stem subsidence. We examined the effect of locally applied bisphosphonate to allografts on prosthetic micromotion and bone density in femoral stem revision with impaction grafting. Methods: 37 patients were randomised to either clodronate or saline as local adjunct to the morsellised allograft bone. 24 patients were finally analysed per protocol and evaluated by dual-energy x-ray absorptiometry (DXA) during the first year and with radiostereometric analysis (RSA) for 5 years. Results: There were no significant differences neither in bone density, nor in migratory behaviour between the groups. The femoral stems had subsided 3.6 mm in both groups (p = 0.99) at 5 years and there was no difference as measured over time with mixed models analysis. The clinical outcome was good in both groups. Conclusion: Clodronate as a local addendum to allograft bone in hip revision did not increase bone density or reduce micromotion of the implant.
  •  
10.
  • Belfrage, Ola, et al. (författare)
  • Preserved periprosthetic bone stock at 5 years post-operatively with uncemented short hip stem in both collared and collarless version
  • 2022
  • Ingår i: Archives of Orthopaedic and Trauma Surgery. - : Springer Science and Business Media LLC. - 0936-8051 .- 1434-3916. ; 142:11, s. 3489-3496
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction: Previous bone density studies have generally shown bone resorption around both cemented and uncemented total hip arthroplasty (THA) stems. This is presumed to be due to stress shielding. Short stems have been introduced partly to preserve bone in the proximal femur by a more physiological loading of the bone. The purpose of this study was to evaluate bone remodeling around a short, fully hydroxyapatite-coated titanium stem that comes in a collared and collarless version. Patients and methods: A prospective cohort of 50 patients included in a study evaluating the Furlong Evolution stem has been followed for 5 years. Examination was done with dual energy X-ray absorptiometry (DXA) postoperatively, at 1, 2 and 5 years. Clinical outcome was followed with radiography and both general and hip specific outcome measures. Results: The two versions of the stem behaved similarly regarding bone remodeling. After an initial decrease up to 1 year, bone mineral density (BMD) increased in all Gruen zones up to 2 years and at 5 years bone stock was still preserved compared with postoperatively (net BMD + 1.2% (95% CI − 0.4 to 2.8)). Increase in BMD occurred mainly in the greater trochanter and distally around the stem with a decrease in the calcar area. Both versions showed excellent clinical outcome up to 5 years. Conclusion: This short stem seems to preserve proximal bone stock up to 5 years, exhibiting similar behaviour both with and without a collar. Trial registration number and date of registration: ClinicalTrials.gov, (identifier: NCT01894854). July 10, 2013.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 53

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy