SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Freeman Bill) "

Sökning: WFRF:(Freeman Bill)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Eatough, Ralph P., et al. (författare)
  • Verification of Radiative Transfer Schemes for the EHT
  • 2020
  • Ingår i: Astrophysical Journal. - : American Astronomical Society. - 1538-4357 .- 0004-637X. ; 897:2
  • Tidskriftsartikel (refereegranskat)abstract
    • The Event Horizon Telescope (EHT) Collaboration has recently produced the first resolved images of the central supermassive black hole in the giant elliptical galaxy M87. Here we report on tests of the consistency and accuracy of the general relativistic radiative transfer codes used within the collaboration to model M87∗ and Sgr A∗. We compare and evaluate (1) deflection angles for equatorial null geodesics in a Kerr spacetime; (2) images calculated from a series of simple, parameterized matter distributions in the Kerr metric using simplified emissivities and absorptivities; (3) for a subset of codes, images calculated from general relativistic magnetohydrodynamics simulations using different realistic synchrotron emissivities and absorptivities; (4) observables for the 2017 configuration of EHT, including visibility amplitudes and closure phases. The error in total flux is of order 1% when the codes are run with production numerical parameters. The dominant source of discrepancies for small camera distances is the location and detailed setup of the software "camera"that each code uses to produce synthetic images. We find that when numerical parameters are suitably chosen and the camera is sufficiently far away the images converge and that for given transfer coefficients, numerical uncertainties are unlikely to limit parameter estimation for the current generation of EHT observations. The purpose of this paper is to describe a verification and comparison of EHT radiative transfer codes. It is not to verify EHT models more generally.
  •  
2.
  • Porth, Oliver, et al. (författare)
  • The Event Horizon General Relativistic Magnetohydrodynamic Code Comparison Project
  • 2019
  • Ingår i: Astrophysical Journal, Supplement Series. - : American Astronomical Society. - 1538-4365 .- 0067-0049. ; 243:2
  • Tidskriftsartikel (refereegranskat)abstract
    • Recent developments in compact object astrophysics, especially the discovery of merging neutron stars by LIGO, the imaging of the black hole in M87 by the Event Horizon Telescope, and high- precision astrometry of the Galactic Center at close to the event horizon scale by the GRAVITY experiment motivate the development of numerical source models that solve the equations of general relativistic magnetohydrodynamics (GRMHD). Here we compare GRMHD solutions for the evolution of a magnetized accretion flow where turbulence is promoted by the magnetorotational instability from a set of nine GRMHD codes: Athena++, BHAC, Cosmos++, ECHO, H-AMR, iharm3D, HARM-Noble, IllinoisGRMHD, and KORAL. Agreement among the codes improves as resolution increases, as measured by a consistently applied, specially developed set of code performance metrics. We conclude that the community of GRMHD codes is mature, capable, and consistent on these test problems.
  •  
3.
  • Sator, Lea, et al. (författare)
  • Overdiagnosis of COPD in Subjects With Unobstructed Spirometry A BOLD Analysis
  • 2019
  • Ingår i: Chest. - : Elsevier BV. - 0012-3692 .- 1931-3543. ; 156:2, s. 277-288
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: There are several reports on underdiagnosis of COPD, while little is known about COPD overdiagnosis and overtreatment. We describe the overdiagnosis and the prevalence of spirometrically defined false positive COPD, as well as their relationship with overtreatment across 23 population samples in 20 countries participating in the BOLD Study between 2003 and 2012.METHODS: A false positive diagnosis of COPD was considered when participants reported a doctor's diagnosis of COPD, but postbronchodilator spirometry was unobstructed (FEV1/FVC > LLN). Additional analyses were performed using the fixed ratio criterion (FEV1/FVC < 0.7).RESULTS: Among 16,177 participants, 919 (5.7%) reported a previous medical diagnosis of COPD. Postbronchodilator spirometry was unobstructed in 569 subjects (61.9%): false positive COPD. A similar rate of overdiagnosis was seen when using the fixed ratio criterion (55.3%). In a subgroup analysis excluding participants who reported a diagnosis of "chronic bronchitis" or "emphysema" (n = 220), 37.7% had no airflow limitation. The site-specific prevalence of false positive COPD varied greatly, from 1.9% in low- to middle-income countries to 4.9% in high-income countries. In multivariate analysis, overdiagnosis was more common among women, and was associated with higher education; former and current smoking; the presence of wheeze, cough, and phlegm; and concomitant medical diagnosis of asthma or heart disease. Among the subjects with false positive COPD, 45.7% reported current use of respiratory medication. Excluding patients with reported asthma, 34.4% of those with normal spirometry still used a respiratory medication.CONCLUSIONS: False positive COPD is frequent. This might expose nonobstructed subjects to possible adverse effects of respiratory medication.
  •  
4.
  • Studnicka, Michael, et al. (författare)
  • COPD : Should Diagnosis Match Physiology?
  • 2020
  • Ingår i: Chest. - : Elsevier BV. - 0012-3692 .- 1931-3543. ; 157:2, s. 473-475
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy