SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Kerek Andras) "

Sökning: WFRF:(Kerek Andras)

  • Resultat 1-10 av 46
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Bäck, Torbjörn, et al. (författare)
  • A TOF-PET system for educational purposes
  • 2002
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 477, s. 82-82
  • Tidskriftsartikel (refereegranskat)abstract
    • A TOF-PET system has been designed and constructed for educational purposes. The aim of this system is to demonstrate the possibilities of positron emission tomography in general and the time-of-flight method in particular to the students of various courses at the Royal Institute of Technology, Stockholm, Sweden. The set-up consists of 48 small BaF2 crystals coupled to fast photomultipliers placed in a ring geometry. The signals of the photomultipliers are fed into fast constant fraction discriminators (CFD). The outputs of these are directed to a specially designed logic VME unit. which combines the CFD signals of 6 neighbouring channels to one signal by adding a different delay to each channel. The logic circuitry produces a prompt pulse for each event that serves as the start pulse for the 8-channel fast TDC. The delayed pulses act as the stop pulses for the TDC. In a computer. the measured times are converted into information about which the photomultipliers fired with the difference in the time of flight. The set-up is described and the results are presented.
  •  
2.
  • Bäck, Torbjörn, et al. (författare)
  • An educational tool for demonstrating the TOF-PET technique
  • 2001
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : AMERICAN PHYSICAL SOC. - 0168-9002 .- 1872-9576. ; 471:1-2, s. 200-204
  • Tidskriftsartikel (refereegranskat)abstract
    • A detector system for positron emission tomography with time-of-flight capability has been built to serve as an educational tool for undergraduate students. The set-up consists of 48 BaF2 scintillator crystals, each coupled to a fast photo-multiplier tube, mounted in a circular geometry. The analogue detector pulses are handled by fast constant fraction discriminators. A dedicated unit reduces the 48 channels to eight channels via delay-fine encoding, and the signals are then fed to an eight channel fast time-to-digital converter. A VME processor sorts the events and sends them to a workstation where the coincident events are extracted. The time resolution of the detectors together with fast VME based electronics allows for time-of-flight measurements to improve on the signal-to-noise ratio in the, reconstructed images. The system can be used for different types of exercises for the students, varying from the fundamentals of scintillator detectors to advanced image reconstruction. The set-up is described and some results are presented. (C) 2001 Elsevier Science B.V. All rights reserved.
  •  
3.
  • Caceres, L., et al. (författare)
  • Nuclear structure studies of F-24
  • 2015
  • Ingår i: Physical Review C. Nuclear Physics. - 0556-2813 .- 1089-490X. ; 92:1
  • Tidskriftsartikel (refereegranskat)abstract
    • The structure of the F-24 nucleus has been studied at GANIL using the beta decay of O-24 and the in-beam.-ray spectroscopy from the fragmentation of Na-27,Na-28, Ne-25,Ne-26, and Mg-29,Mg-30 nuclei. Combining these complementary experimental techniques, the level scheme of F-24 has been constructed up to 3.6 MeV by means of particle-gamma and particle-gamma gamma coincidence relations. Experimental results are compared to shell-model calculations using the standard USDA and USDB interactions as well as ab initio valence-space Hamiltonians calculated from the in-medium similarity renormalization group based on chiral two- and three-nucleon forces. Both methods reproduce the measured level spacings well, and this close agreement allows unidentified spins and parities to be consistently assigned.
  •  
4.
  • Claesson, T., et al. (författare)
  • An X-ray computed tomography demonstrator using a CZT solid-state detector
  • 2002
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - 0168-9002 .- 1872-9576. ; 487:02-jan, s. 202-208
  • Tidskriftsartikel (refereegranskat)abstract
    • A demonstrator of Computed Tomography (CT) has been designed and built for educational purposes. The system is based on a solid-state CdZnTe detector and a standard PC. The mechanics of the system is controlled and data is acquired by programs written in LabVIEW. CT images are reconstructed using MATLAB programs.
  •  
5.
  • Dénes, E., et al. (författare)
  • Radiation tolerance qualification tests of the final source interface unit for the ALICE experiment for the ALICE collaboration
  • 2007
  • Ingår i: Proceedings - 12th Workshop on Electronics for LHC and Future Experiments, LECC 2006. - : CERN. ; , s. 438-441
  • Konferensbidrag (refereegranskat)abstract
    • The ALICE Detector Data Link (DDL) is a high-speed optical link designed to interface the readout electronics of ALICE sub-detectors to the DAQ computers. The Source Interface Unit (SIU) of the DDL will operate in radiation environment. Previous tests showed that a configuration loss of SRAM-based FPGA devices may happen and the frequency of undetected data errors in the FPGA user memory area is also not acceptable. Therefore, we redesigned the SIU card using another FPGA based on flash technology. In order to detect bit errors in the user memory we added parity check logic to the design. The new SIU has been extensively tested using neutron and proton irradiation to verify its radiation tolerance. In this paper we summarize the design changes, introduce the final design, and the results of the radiation tolerance measurements on the final card.
  •  
6.
  • Dénes, E., et al. (författare)
  • Radiation tolerant source interface unit for the ALICE experiment
  • 2005
  • Ingår i: Proceedings - 11th Workshop on Electronics for LHC and Future Experiments, LECC 2005. - : CERN. ; , s. 291-293
  • Konferensbidrag (refereegranskat)abstract
    • The ALICE Detector Data Link (DDL) is a high-speed optical link designed to interface the readout electronics of ALICE sub-detectors to the DAQ computers. The Source Interface Unit (SIU) of the DDL will operate in radiation environment. Tests showed that configuration loss of the Altera APEX II FPGA device used earlier on the DDL SIU card is only marginally acceptable. We developed a new version of the SIU card using Actel ProASIC+ device based on flash memory technology. The new SIU card has been extensively tested using neutron and proton irradiation. In this paper we present the SIU card and describe the results of irradiation measurements.
  •  
7.
  • Emri, M., et al. (författare)
  • Software development framework supporting multimodal tomographic imaging
  • 2007
  • Ingår i: 2006 IEEE Nuclear Science Symposium Conference Record. - : IEEE. - 1424405610 - 9781424405619 ; , s. 1857-1859
  • Konferensbidrag (refereegranskat)abstract
    • Engineers specialized in multimodal tomography regularly face a wide scale of programming tasks requiring an integrated software system to ensure cost efficiency. Accordingly, a software development framework has been worked out comprising libraries for cluster-based data acquisition, image reconstruction, management of data files and complex multimodal volumetric visualization. This framework enabled us to develop complex software for our miniPET project [1]. This software contains a graphical application integrating data acquisition, cluster monitoring, event sorting, image reconstruction, interactive image processing tools for advanced multimodal visualization. It also contains utilities to solve these tasks without graphical user interface. The components of our acquisition program can run on embedded Linux systems making new ways to develop any other types of data acquisition software that uses embedded Linux systems. A versatile development framework is developed containing specific libraries and special file formats that support multimodal tomography. This framework was successfully used to elaborate our complex miniPET software.
  •  
8.
  • Franchoo, S., et al. (författare)
  • RECENT RESULTS FROM GANIL
  • 2009
  • Ingår i: Acta Physica Polonica B. - 0587-4254 .- 1509-5770. ; 40:3, s. 419-425
  • Tidskriftsartikel (refereegranskat)abstract
    • The shell structure of the nucleus implies the existence of magic numbers. Since several years many indications have been accumulated, theoretically as well as through experiments at various laboratories around the world, that if one moves away from stability, the location of the magic numbers shifts as an inescapable consequence of the evolving nature of the nuclear force itself. In this respect, it is the balance between the tensor and spin-orbit components that seems particularly instrumental. Illustrative examples from recent experiments at Ganil, at the neutron-rich and proton-rich side of the nuclear chart for N or Z equal 20 or 28, will be presented here.
  •  
9.
  • Hegyesi, G., et al. (författare)
  • Development of an FPGA-based data acquisition module for small animal PET
  • 2004
  • Ingår i: 2004 IEEE Nuclear Science Symposium Conference Record. - 0780387007 ; , s. 2957-2961
  • Konferensbidrag (refereegranskat)abstract
    • We report on the design of a DAQ module for a small animal PET camera developed at our institutes. During the design an important guideline was to develop a system which is built up from strictly identical DAQ modules, and which has no built-in hardware limitation on the maximum number of modules. The developed DAQ module comprises of an LSO scintillator crystal block, a position sensitive PMT, analog signal conditioning circuits, a digitizer, an FPGA for digital signal processing and a communication module through which the collected data is sent to a cluster of computers for post processing and storage. Instead of implementing hardware coincidence detection between the modules we attach a precise time-stamp to each event in our design, and the coincidence is determined by the data collecting computers during the post processing. The digital CFD algorithm implemented in the FPGA gives a time resolution of 2 to 3 ns FWHM for real detector signals.
  •  
10.
  • Hegyesi, G., et al. (författare)
  • Ethernet based distributed data acquisition system for a small animal PET
  • 2006
  • Ingår i: IEEE Transactions on Nuclear Science. - 0018-9499 .- 1558-1578. ; 53:4, s. 2112-2117
  • Tidskriftsartikel (refereegranskat)abstract
    • We report on the design of a small animal PET scanner being developed at our institutes. The existing setup is the first version of the miniPET machine consisting of four detector modules. Each detector module consists of an 8 x 8 LSO scintillator crystal block, a position sensitive photomultiplier, a digitizer including a digital signal processing board and an Ethernet interface board. There is no hardware coincidence detection implemented in the system and coincidence is determined based on a time stamp attached to every event by a digital CFD algorithm. The algorithm is implemented in the digital signal processing board and generates a time stamp with a coincidence resolution of less than 2 us. The data acquisition system is based on Ethernet network and is highly scalable in size and performance.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 46

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy