1.
  • Andreasson, Ulf, 1968, et al. (författare)
  • Commutability of the certified reference materials for the standardization of beta-amyloid 1-42 assay in human cerebrospinal fluid: lessons for tau and beta-amyloid 1-40 measurements
  • 2018
  • Ingår i: Clinical Chemistry and Laboratory Medicine. - : Walter de Gruyter GmbH. - 1434-6621 .- 1437-4331. ; 56:12, s. 2058-2066
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: The core Alzheimer's disease cerebrospinal fluid (CSF) biomarkers total tau (T-tau), phosphorylated tau (P-tau), beta-amyloid 1-42 (A beta 42) and beta-amyloid 1-40 (A beta 40) are increasing in importance and are now part of the research criteria for the diagnosis of the disease. The main aim of this study is to evaluate whether a set of certified reference materials (CRMs) are commutable for A beta 42 and to serve as a feasibility study for the other markers. This property is a prerequisite for the establishment of CRMs which will then be used by manufacturers to calibrate their assays against. Once the preanalytical factors have been standardized and proper selection criteria are available for subject cohorts this harmonization between methods will allow for universal cut-offs to be determined. Methods: Thirty-four individual CSF samples and three different CRMs where analyzed for T-tau, P-tau, A beta 42 and A beta 40, using up to seven different commercially available methods. For A beta 40 and A beta 42 a mass spectrometry-based procedure was also employed. Results: There were strong pairwise correlations between the different methods (Spearman's p>0.92) for all investigated analytes and the CRMs were not distinguishable from the individual samples. Conclusions: This study shows that the CRMs are commutable for the different assays for A beta 42. For the other analytes the results show that it would be feasible to also produce CRMs for these. However, additional studies are needed as the concentration interval for the CRMs were selected based on A beta 42 concentrations only and did in general not cover satisfactory large concentration intervals for the other analytes.
  •  
2.
  • Boulo, S., et al. (författare)
  • First amyloid β1-42 certified reference material for re-calibrating commercial immunoassays
  • 2020
  • Ingår i: Alzheimer's and Dementia. - : Wiley. - 1552-5260 .- 1552-5279. ; 16:11, s. 1493-1503
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction: Reference materials based on human cerebrospinal fluid were certified for the mass concentration of amyloid beta (Aβ)1-42 (Aβ42). They are intended to be used to calibrate diagnostic assays for Aβ42. Methods: The three certified reference materials (CRMs), ERM-DA480/IFCC, ERM-DA481/IFCC and ERM-DA482/IFCC, were prepared at three concentration levels and characterized using isotope dilution mass spectrometry methods. Roche, EUROIMMUN, and Fujirebio used the three CRMs to re-calibrate their immunoassays. Results: The certified Aβ42 mass concentrations in ERM-DA480/IFCC, ERM-DA481/IFCC, and ERM-DA482/IFCC are 0.45, 0.72, and 1.22μg/L, respectively, with expanded uncertainties (k=2) of 0.07, 0.11, and 0.18μg/L, respectively. Before re-calibration, a good correlation (Pearson's r>0.97), yet large biases, were observed between results from different commercial assays. After re-calibration the between-assay bias was reduced to<5%. Discussion: The Aβ42 CRMs can ensure the equivalence of results between methods and across platforms for the measurement of Aβ42. © 2020 the Alzheimer's Association
  •  
3.
  • Shaw, L. M., et al. (författare)
  • Method comparison study of the Elecsys® β-Amyloid (1–42) CSF assay versus comparator assays and LC-MS/MS
  • 2019
  • Ingår i: Clinical Biochemistry. - : Elsevier BV. - 0009-9120. ; 72:October, s. 7-14
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Alzheimer's disease (AD) biomarkers, such as cerebrospinal fluid (CSF) amyloid-β (1–42; Aβ42), can provide high diagnostic accuracy. Several immunoassays are available for Aβ42 quantitation, but standardisation across assays remains an issue. We compared the Elecsys® β-Amyloid (1–42) CSF assay with three assays and two liquid chromatography tandem mass spectrometry (LC-MS/MS) methods. Methods: Three method comparison studies evaluated the correlation between the Elecsys® β-Amyloid (1–42) CSF assay versus: INNOTEST® β-AMYLOID(1–42) (860 samples) and the Roche Diagnostics-developed LC-MS/MS method (250 samples); INNO-BIA AlzBio3 and the University of Pennsylvania (UPenn)-developed LC-MS/MS method (250 samples); and ADx-EUROIMMUN Beta-Amyloid (1–42) enzyme-linked immunosorbent assay (ELISA) (49 samples). Results: High correlation was demonstrated between Elecsys® β-Amyloid (1–42) CSF and comparator assays: INNOTEST® β-AMYLOID(1–42) (Spearman's ρ, 0.954); INNO-BIA AlzBio3 (Spearman's ρ, 0.864); ADx-EUROIMMUN Beta-Amyloid (1–42) ELISA (Pearson's r, 0.925). Elecsys® assay and LC-MS/MS measurements were highly correlated: Pearson's r, 0.949 (Roche Diagnostics-developed method) and 0.943 (UPenn-developed method). Conclusion: Findings from this multicentre evaluation further support use of the Elecsys® β-Amyloid (1–42) CSF assay to aid AD diagnosis. CSF-based certified reference materials should improve agreement across assays and mass spectrometry-based methods, which is essential to establish a global uniform CSF Aβ42 cut-off to detect amyloid pathology. © 2019
  •  
Skapa referenser, mejla, bekava och länka