SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Raichlen J) "

Sökning: WFRF:(Raichlen J)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Speakman, John R., et al. (författare)
  • Total daily energy expenditure has declined over the past three decades due to declining basal expenditure, not reduced activity expenditure
  • 2023
  • Ingår i: Nature Metabolism. - : NATURE PORTFOLIO. - 2522-5812. ; 5:4, s. 579-588
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • Obesity is caused by a prolonged positive energy balance(1,2). Whether reduced energy expenditure stemming from reduced activity levels contributes is debated(3,4). Here we show that in both sexes, total energy expenditure (TEE) adjusted for body composition and age declined since the late 1980s, while adjusted activity energy expenditure increased over time. We use the International Atomic Energy Agency Doubly Labelled Water database on energy expenditure of adults in the United States and Europe (n = 4,799) to explore patterns in total (TEE: n = 4,799), basal (BEE: n = 1,432) and physical activity energy expenditure (n = 1,432) over time. In males, adjusted BEE decreased significantly, but in females this did not reach significance. A larger dataset of basal metabolic rate (equivalent to BEE) measurements of 9,912 adults across 163 studies spanning 100 years replicates the decline in BEE in both sexes. We conclude that increasing obesity in the United States/Europe has probably not been fuelled by reduced physical activity leading to lowered TEE. We identify here a decline in adjusted BEE as a previously unrecognized factor.
  •  
3.
  • Peters, S. A. E., et al. (författare)
  • Increased age, high body mass index and low HDL-C levels are related to an echolucent carotid intima-media : the METEOR study
  • 2012
  • Ingår i: Journal of Internal Medicine. - : Wiley. - 0954-6820 .- 1365-2796. ; 272:3, s. 257-266
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction. Echolucent plaques are related to a higher cardiovascular risk. Studies to investigate the relationship between echolucency and cardiovascular risk in the early stages of atherosclerosis are limited. We studied the relationship between cardiovascular risk factors and echolucency of the carotid intimamedia in low-risk individuals.Methods. Data were analysed from the Measuring Effects on Intima-Media Thickness: an Evaluation of Rosuvastatin (METEOR) study, a randomized placebo-controlled trial including 984 individuals which showed that rosuvastatin attenuated the rate of change of carotid intimamedia thickness (CIMT). In this post hoc analysis, duplicate baseline ultrasound images from the far wall of the left and right common carotid arteries were used for the evaluation of the echolucency of the carotid intimamedia, measured by grey-scale median (GSM) on a scale of 0256. Low GSM values reflect echolucent, whereas high values reflect echogenic structures. The relationship between baseline GSM and cardiovascular risk factors was evaluated using linear regression models.Results. Mean baseline GSM (+/- SD) was 84 +/- 29. Lower GSM of the carotid intimamedia was associated with older age, high body mass index (BMI) and low levels of high-density lipoprotein cholesterol (HDL-C) [beta -4.49, 95% confidence interval (CI) -6.50 to -2.49; beta -4.51, 95% CI -6.43 to -2.60; beta 2.45, 95% CI 0.47 to 4.42, respectively]. Common CIMT was inversely related to GSM of the carotid intimamedia (beta -3.94, 95% CI -1.98 to -5.89).Conclusion. Older age, high BMI and low levels of HDL-C are related to echolucency of the carotid intimamedia. Hence, echolucency of the carotid intimamedia may be used as a marker of cardiovascular risk profile to provide more information than thickness alone.
  •  
4.
  • Peters, S A E, et al. (författare)
  • Manual or semi-automated edge detection of the maximal far wall common carotid intima-media thickness : a direct comparison
  • 2012
  • Ingår i: Journal of Internal Medicine. - : Wiley. - 0954-6820 .- 1365-2796. ; 271:3, s. 247-256
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Automated edge detection is thought to be superior to manual edge detection in quantification of the far wall common carotid intima-media thickness (CIMT), yet published evidence making a direct comparison is not available. Methods: Data were used from the METEOR study, a randomized placebo-controlled trial among 984 individuals showing that rosuvastatin attenuated the rate of change of 2 year change in CIMT among low-risk individuals with subclinical atherosclerosis. For this post hoc analysis, CIMT images of the far wall of the common carotid artery were evaluated using manual and semi-automated edge detection and reproducibility, relation to cardiovascular risk factors, rates of change over time and effects of lipid-lowering therapy were assessed. Results: Reproducibility was high for both reading methods. Direction, magnitude and statistical significance of risk factor relations were similar across methods. Rate of change in CIMT in participants assigned to placebo was 0.0066 mm per year (SE: 0.0027) for manually and 0.0072 mm per year (SE: 0.0029) for semi-automatically read images. The effect of lipid-lowering therapy on CIMT changes was -0.0103 mm per year (SE: 0.0032) for manual reading and -0.0111 mm per year (SE: 0.0034) for semi-automated reading. Conclusion: Manual and semi-automated readings of the maximal far wall of the common CIMT images both result in high reproducibility, show similar risk factor relations, rates of change and treatment effects. Hence, choices between semi-automated and manual reading software for CIMT studies likely should be based on logistical and cost considerations rather than differences in expected data quality when the choice is made to use far wall common CIMT measurements.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy