SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Riambau V.) "

Sökning: WFRF:(Riambau V.)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Ederle, Joerg, et al. (författare)
  • Carotid artery stenting compared with endarterectomy in patients with symptomatic carotid stenosis (International Carotid Stenting Study): an interim analysis of a randomised controlled trial
  • 2010
  • Ingår i: The Lancet. - 1474-547X. ; 375:9719, s. 985-997
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Stents are an alternative treatment to carotid endarterectomy for symptomatic carotid stenosis, but previous trials have not established equivalent safety and efficacy. We compared the safety of carotid artery stenting with that of carotid endarterectomy. Methods The International Carotid Stenting Study (ICSS) is a multicentre, international, randomised controlled trial with blinded adjudication of outcomes. Patients with recently symptomatic carotid artery stenosis were randomly assigned in a 1:1 ratio to receive carotid artery stenting or carotid endarterectomy. Randomisation was by telephone call or fax to a central computerised service and was stratified by centre with minimisation for sex, age, contralateral occlusion, and side of the randomised artery. Patients and investigators were not masked to treatment assignment. Patients were followed up by independent clinicians not directly involved in delivering the randomised treatment. The primary outcome measure of the trial is the 3-year rate of fatal or disabling stroke in any territory, which has not been analysed yet. The main outcome measure for the interim safety analysis was the 120-day rate of stroke, death, or procedural myocardial infarction. Analysis was by intention to treat (ITT). This study is registered, number ISRCTN25337470. Findings The trial enrolled 1713 patients (stenting group, n=855; endarterectomy group, n=858). Two patients in the stenting group and one in the endarterectomy group withdrew immediately after randomisation, and were not included in the ITT analysis. Between randomisation and 120 days, there were 34 (Kaplan-Meier estimate 4.0%) events of disabling stroke or death in the stenting group compared with 27 (3.2%) events in the endarterectomy group (hazard ratio [HR] 1.28, 95% CI 0.77-2.11). The incidence of stroke, death, or procedural myocardial infarction was 8.5% in the stenting group compared with 5.2% in the endarterectomy group (72 vs 44 events; HR 1.69, 1.16-2.45, p=0.006), Risks of any stroke (65 vs 35 events; HR 1.92, 1.27-2.89) and all-cause death (19 vs seven events; HR 2.76, 1.16-6.56) were higher in the stenting group than in the endarterectomy group. Three procedural myocardial infarctions were recorded in the stenting group, all of which were fatal, compared with four, all non-fatal, in the endarterectomy group. There was one event of cranial nerve palsy in the stenting group compared with 45 in the endarterectomy group. There were also fewer haematomas of any severity in the stenting group than in the endarterectomy group (31 vs 50 events; p=0.0197). Interpretation Completion of long-term follow-up is needed to establish the efficacy of carotid artery stenting compared with endarterectomy. In the meantime, carotid endarterectomy should remain the treatment of choice for patients suitable for surgery.
  •  
2.
  •  
3.
  •  
4.
  •  
5.
  • Uberoi, R, et al. (författare)
  • Global Post-Market Clinical Follow-up of the Treovance Stent-Graft for Endovascular Aneurysm Repair: One-Year Results From the RATIONALE Registry
  • 2018
  • Ingår i: Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists. - : SAGE Publications. - 1545-1550. ; 25:6, s. 726-734
  • Tidskriftsartikel (refereegranskat)abstract
    • To evaluate the safety and performance of the Treovance stent-graft. Methods: The global, multicenter RATIONALE registry ( ClinicalTrials.gov; identifier NCT03449875) prospectively enrolled 202 patients (mean age 73.0±7.8 years; 187 men) with abdominal aortic aneurysms (AAA) suitable for endovascular aneurysm repair (EVAR) using the Treovance. The composite primary safety endpoint was site-reported all-cause mortality and major morbidity. The primary efficacy outcome was clinical success. Further outcomes evaluated included technical success; stent-graft migration, patency, and integrity; endoleak; and aneurysm size changes. Results: Technical success was 96% (194/202); 8 patients had unresolved type I endoleaks at the end of the procedure. There was no 30-day mortality and 1% major morbidity (1 myocardial infarction and 1 bowel ischemia). Clinical success at 1 year was confirmed in 194 (96%) patients; 6 of 8 patients had new/persistent endoleaks and 2 had aneurysm expansion without identified endoleak. A total of 8 (4%) reinterventions were required during the mean 13.7±3.1 months of follow-up (median 12.8). At 1 year, the Kaplan-Meier estimate for freedom from reintervention was 95.6% (95% CI 91.4% to 97.8%). Other estimates were 95.5% (95% CI 91.7% to 97.6%) for freedom from endoleak type I/III and 97.4% (95% CI 94.2% to 98.9%) for freedom from aneurysm expansion. Thirteen (6.4%) patients died; no death was aneurysm related. Conclusion: The RATIONALE registry showed favorable safety and clinical performance of the Treovance stent-graft for the treatment of infrarenal AAAs in a real-world setting.
  •  
6.
  • Verhoeven, E. L. G., et al. (författare)
  • Real-world Performance of the New C3 Gore Excluder Stent-Graft : 1-year Results from the European C3 Module of the Global Registry for Endovascular Aortic Treatment (GREAT)
  • 2014
  • Ingår i: European Journal of Vascular and Endovascular Surgery. - : Elsevier BV. - 1078-5884 .- 1532-2165. ; 48:2, s. 131-137
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: The European C3 module of the Global Registry for Endovascular Aortic Treatment (GREAT) provides "real-world" outcomes for the new C3 Gore Excluder stent-graft, and evaluates the new deployment mechanism. This report presents the 1-year results from 400 patients enrolled in this registry. Methods: Between August 2010 and December 2012, 400 patients (86.8% male, mean age 73.9 +/- 7.8 years) from 13 European sites were enrolled in this registry. Patient demographics, treatment indication, case planning, operative details including repositioning and technical results, and clinical outcome were analyzed. Results: Technical success was achieved in 396/400 (99%) patients. Two patients needed intraoperative open conversion, one for iliac rupture, the second because the stent-graft was pulled down during a cross-over catheterization in an angulated anatomy. Two patients required an unplanned chimney renal stent to treat partial coverage of the left renal artery because of upward displacement of the stent-graft. Graft repositioning occurred in 192/399 (48.1%) patients, most frequently for level readjustment with regard to the renal arteries, and less commonly for contralateral gate reorientation. Final intended position of the stent-graft below the renal arteries was achieved in 96.2% of patients. Thirty-day mortality was two (0.5%) patients. Early reintervention (<= 30 days) was required in two (0.5%) patients. Mean follow-up duration was 15.9 +/- 8.8 months (range 0-37 months). Late reintervention (>30 days) was required in 26 (6.5%) patients. Estimated freedom from reintervention at 1 year was 95.2% (95% CI 92.3-97%), and at 2 years 91.5% (95% CI 86.8-94.5%). Estimated patient survival at 1 year was 96% (95% CI 93.3-97.6%) and at 2 years 90.6% (95% CI 85.6-93.9%). Conclusions: Early real-world experience shows that the new C3 delivery system offers advantages in terms of device repositioning resulting in high deployment accuracy. Longer follow-up is required to confirm that this high deployment accuracy results in improved long-term durability.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy