SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Ridolfi M.) "

Sökning: WFRF:(Ridolfi M.)

  • Resultat 1-10 av 13
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Kerzenmacher, T., et al. (författare)
  • Validation of NO2 and NO from the Atmospheric Chemistry Experiment (ACE)
  • 2008
  • Ingår i: Atmospheric Chemistry and Physics. - : Copernicus GmbH. - 1680-7316 .- 1680-7324. ; 8:19, s. 5801--5841-
  • Tidskriftsartikel (refereegranskat)abstract
    • Vertical profiles of NO2 and NO have been obtained from solar occultation measurements by the Atmospheric Chemistry Experiment (ACE), using an infrared Fourier Transform Spectrometer (ACE-FTS) and (for NO2) an ultraviolet-visible-near-infrared spectrometer, MAESTRO (Measurement of Aerosol Extinction in the Stratosphere and Troposphere Retrieved by Occultation). In this paper, the quality of the ACE-FTS version 2.2 NO2 and NO and the MAESTRO version 1.2 NO2 data are assessed using other solar occultation measurements (HALOE, SAGE II, SAGE III, POAM III, SCIAMACHY), stellar occultation measurements (GOMOS), limb measurements (MIPAS, OSIRIS), nadir measurements (SCIAMACHY), balloon-borne measurements (SPIRALE, SAOZ) and ground-based measurements (UV-VIS, FTIR). Time differences between the comparison measurements were reduced using either a tight coincidence criterion, or where possible, chemical box models. ACE-FTS NO2 and NO and the MAESTRO NO2 are generally consistent with the correlative data. The ACE-FTS and MAESTRO NO2 volume mixing ratio (VMR) profiles agree with the profiles from other satellite data sets to within about 20% between 25 and 40 km, with the exception of MIPAS ESA (for ACE-FTS) and SAGE II (for ACE-FTS (sunrise) and MAESTRO) and suggest a negative bias between 23 and 40 km of about 10%. MAESTRO reports larger VMR values than the ACE-FTS. In comparisons with HALOE, ACE-FTS NO VMRs typically (on average) agree to ±8% from 22 to 64 km and to +10% from 93 to 105 km, with maxima of 21% and 36%, respectively. Partial column comparisons for NO2 show that there is quite good agreement between the ACE instruments and the FTIRs, with a mean difference of +7.3% for ACE-FTS and +12.8% for MAESTRO.
  •  
2.
  • Wolff, M.A., et al. (författare)
  • Validation of HNO3, ClONO2 and N2O5 from the Atmospheric Chemistry Experiment Fourier Transform Spectrometer (ACE-FTS)
  • 2008
  • Ingår i: Atmospheric Chemistry and Physics. - : Copernicus GmbH. - 1680-7316 .- 1680-7324. ; 8:13, s. 3529-3562
  • Tidskriftsartikel (refereegranskat)abstract
    • The Atmospheric Chemistry Experiment (ACE) satellite was launched on 12 August 2003. Its two instruments measure vertical profiles of over 30 atmospheric trace gases by analyzing solar occultation spectra in the ultraviolet/visible and infrared wavelength regions. The reservoir gases HNO3, ClONO2, and N2O5 are three of the key species provided by the primary instrument, the ACE Fourier Transform Spectrometer (ACE-FTS). This paper describes the ACE-FTS version 2.2 data products, including the N2O5 update, for the three species and presents validation comparisons with available observations. We have compared volume mixing ratio (VMR) profiles of HNO3, ClONO2, and N2O5 with measurements by other satellite instruments (SMR, MLS, MIPAS), aircraft measurements (ASUR), and single balloon-flights (SPIRALE, FIRS-2). Partial columns of HNO3 and ClONO2 were also compared with measurements by ground-based Fourier Transform Infrared (FTIR) spectrometers. Overall the quality of the ACE-FTS v2.2 HNO3 VMR profiles is good from 18 to 35 km. For the statistical satellite comparisons, the mean absolute differences are generally within ±1 ppbv ±20%) from 18 to 35 km. For MIPAS and MLS comparisons only, mean relative differences lie within±10% between 10 and 36 km. ACE-FTS HNO3 partial columns (~15–30 km) show a slight negative bias of −1.3% relative to the ground-based FTIRs at latitudes ranging from 77.8° S–76.5° N. Good agreement between ACE-FTS ClONO2 and MIPAS, using the Institut für Meteorologie und Klimaforschung and Instituto de Astrofísica de Andalucía (IMK-IAA) data processor is seen. Mean absolute differences are typically within ±0.01 ppbv between 16 and 27 km and less than +0.09 ppbv between 27 and 34 km. The ClONO2 partial column comparisons show varying degrees of agreement, depending on the location and the quality of the FTIR measurements. Good agreement was found for the comparisons with the midlatitude Jungfraujoch partial columns for which the mean relative difference is 4.7%. ACE-FTS N2O5 has a low bias relative to MIPAS IMK-IAA, reaching −0.25 ppbv at the altitude of the N2O5 maximum (around 30 km). Mean absolute differences at lower altitudes (16–27 km) are typically −0.05 ppbv for MIPAS nighttime and ±0.02 ppbv for MIPAS daytime measurements.
  •  
3.
  • Welsh, Joshua A., et al. (författare)
  • Minimal information for studies of extracellular vesicles (MISEV2023): From basic to advanced approaches
  • 2024
  • Ingår i: Journal of Extracellular Vesicles. - : John Wiley and Sons Inc. - 2001-3078. ; 13:2
  • Tidskriftsartikel (refereegranskat)abstract
    • Extracellular vesicles (EVs), through their complex cargo, can reflect the state of their cell of origin and change the functions and phenotypes of other cells. These features indicate strong biomarker and therapeutic potential and have generated broad interest, as evidenced by the steady year-on-year increase in the numbers of scientific publications about EVs. Important advances have been made in EV metrology and in understanding and applying EV biology. However, hurdles remain to realising the potential of EVs in domains ranging from basic biology to clinical applications due to challenges in EV nomenclature, separation from non-vesicular extracellular particles, characterisation and functional studies. To address the challenges and opportunities in this rapidly evolving field, the International Society for Extracellular Vesicles (ISEV) updates its ‘Minimal Information for Studies of Extracellular Vesicles’, which was first published in 2014 and then in 2018 as MISEV2014 and MISEV2018, respectively. The goal of the current document, MISEV2023, is to provide researchers with an updated snapshot of available approaches and their advantages and limitations for production, separation and characterisation of EVs from multiple sources, including cell culture, body fluids and solid tissues. In addition to presenting the latest state of the art in basic principles of EV research, this document also covers advanced techniques and approaches that are currently expanding the boundaries of the field. MISEV2023 also includes new sections on EV release and uptake and a brief discussion of in vivo approaches to study EVs. Compiling feedback from ISEV expert task forces and more than 1000 researchers, this document conveys the current state of EV research to facilitate robust scientific discoveries and move the field forward even more rapidly.
  •  
4.
  •  
5.
  • Kiefer, M., et al. (författare)
  • Characterization of MIPAS elevation pointing
  • 2007
  • Ingår i: Atmospheric Chemistry And Physics. - : Copernicus GmbH. - 1680-7316 .- 1680-7324. ; 7:6, s. 1615-1628
  • Tidskriftsartikel (refereegranskat)abstract
    • Sufficient knowledge of the pointing is essential for analyses of limb emission measurements. The scientific retrieval processor for MIPAS on ENVISAT operated at IMK allows the retrieval of pointing information in terms of tangent altitudes along with temperature. The retrieved tangent altitudes are independent of systematic offsets in the engineering Line-Of-Sight (LOS) information delivered with the ESA Level 1b product. The difference of pointing retrieved from the reprocessed high resolution MIPAS spectra and the engineering pointing information was examined with respect to spatial/temporal behaviour. Among others the following characteristics of MIPAS pointing could be identified: Generally the engineering tangent altitudes are too high by 0–1.8 km with conspicuous variations in this range over time. Prior to December of 2003 there was a drift of about 50–100 m/h, which was due to a slow change in the satellite attitude. A correction of this attitude is done twice a day, which leads to discontinuities in the order of 1–1.5 km in the tangent altitudes. Occasionally discontinuities up to 2.5 km are found, as already reported from MIPAS and SCIAMACHY observations. After an update of the orbit position software in December 2003 values of drift and jumps are much reduced. There is a systematic difference in the mispointing between the poles which amounts to 1.5–2 km, i.e. there is a conspicuous orbit-periodic feature. The analysis of the correlation between the instrument's viewing angle azimuth and differential mispointing supports the hypotheses that a major part of this latter phenomenon can be attributed to an error in the roll angle of the satellite/instrument system of approximately 42 mdeg. One conclusion is that ESA level 2 data should be compared to other data exclusively on tangent pressure levels. Complementary to IMK data, ESA operational LOS calibration results were used to characterize MIPAS pointing. For this purpose MIPAS is used as a radiometer while the passage of infrared bright stars through the instrument's field of view is recorded. Deviation from expected time of passage gives information about mispointing. Results are: a pronounced seasonal variation of the LOS is seen before a correction of on-board software took place in December of 2003. Further a pitch bias of 26 mdeg with respect to the platform attitude information is found, which corresponds to 1.45 km tangent altitude offset towards low altitudes.
  •  
6.
  • Blösch, Günter, et al. (författare)
  • Twenty-three unsolved problems in hydrology (UPH) - a community perspective
  • 2019
  • Ingår i: Hydrological Sciences Journal. - : Informa UK Limited. - 0262-6667 .- 2150-3435. ; 64:10, s. 1141-1158
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper is the outcome of a community initiative to identify major unsolved scientific problems in hydrology motivated by a need for stronger harmonisation of research efforts. The procedure involved a public consultation through online media, followed by two workshops through which a large number of potential science questions were collated, prioritised, and synthesised. In spite of the diversity of the participants (230 scientists in total), the process revealed much about community priorities and the state of our science: a preference for continuity in research questions rather than radical departures or redirections from past and current work. Questions remain focused on the process-based understanding of hydrological variability and causality at all space and time scales. Increased attention to environmental change drives a new emphasis on understanding how change propagates across interfaces within the hydrological system and across disciplinary boundaries. In particular, the expansion of the human footprint raises a new set of questions related to human interactions with nature and water cycle feedbacks in the context of complex water management problems. We hope that this reflection and synthesis of the 23 unsolved problems in hydrology will help guide research efforts for some years to come.
  •  
7.
  • Von Clarmann, T., et al. (författare)
  • A blind test retrieval experiment for infrared limb emission spectrometry
  • 2003
  • Ingår i: Journal of Geophysical Research - Atmospheres. - 2169-897X .- 2169-8996. ; 108:D23
  • Tidskriftsartikel (refereegranskat)abstract
    • The functionality and characteristics of six different data processors (i.e., retrieval codes in their actual software and hardware environment) for analysis of high-resolution limb emission infrared spectra recorded by the space-borne Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) have been validated by means of a blind test retrieval experiment based on synthetic spectra. For this purpose a self-consistent set of atmospheric state parameters, including pressure, temperature, vibrational temperatures, and abundances of trace gases and aerosols, has been generated and used as input for radiative transfer calculations for MIPAS measurement geometry and configuration. These spectra were convolved with the MIPAS field of view, spectrally degraded by the MIPAS instrument line shape, and, finally, superimposed with synthetic measurement noise. These synthetic MIPAS measurements were distributed among the participants of the project “Advanced MIPAS level-2 data analysis” (AMIL2DA), who performed temperature and species abundance profile retrievals by inverse radiative transfer calculations. While the retrieved profiles of atmospheric state parameters reflect some characteristics of the individual data processors, it was shown that all the data processors under investigation are capable of producing reliable results in the sense that deviations of retrieved results from the reference profiles are within the margin that is consistent with analytical error estimation.
  •  
8.
  • Alonso Vicario, S., et al. (författare)
  • Unravelling the influence of human behaviour on reducing casualties during flood evacuation
  • 2020
  • Ingår i: Hydrological Sciences Journal. - : Informa UK Limited. - 0262-6667 .- 2150-3435. ; 65:14, s. 2359-2375
  • Tidskriftsartikel (refereegranskat)abstract
    • Floods are the natural hazards that are causing the most deaths worldwide. Flood early warning systems are one of the most cost-efficient methods to reduce death rates, triggering decisions about the evacuation of exposed population. Although previous studies have investigated the effect of human behaviours on evacuation processes, studies analysing a combination of behaviours, flood onset and warning timing are limited. Our objective is to explore how changes on the aforementioned factors can affect casualties. This is done within a modelling framework that includes an agent-based model, a hydraulic model, and a traffic model, which is implemented for the case study of Orvieto (Italy). The results show that the number of casualties is most impacted by people's behaviour. Besides, we found that a delay of 30 min in releasing the warning can boost the number of casualties up to six times. These results may help managers to propose effective emergency plans.
  •  
9.
  •  
10.
  • Pani, R., et al. (författare)
  • Investigation of radiation detection properties of CRY-018 and CRY-019 scintillators for medical imaging
  • 2016
  • Ingår i: Journal of Instrumentation. - : IOP PUBLISHING LTD. - 1748-0221 .- 1748-0221. ; 11
  • Tidskriftsartikel (refereegranskat)abstract
    • During the last years the research for new scintillation crystals has been crucial for the improvement of imaging performance in nuclear medicine applications. Crytur company has recently released two new scintillators named CRY-018 and CRY-019 which are non hygroscopic, have short decay time and low refraction index. They represent the ideal candidates to substitute NaI:Tl and BGO crystals in future PET ad SPECT applications. The purpose of this work is to characterize this unknown crystals, look for possible applications in imaging for nuclear medicine. The results of this work were compared with the results obtained with a LaBr3:ce scintillation crystal. This particular crystal is used as a comparison benchmark because of its strong linear pulse height uniformity response and high energy resolution. Measurements have been performed with a high count rate which is typical for medical applications. Irradiation of the crystals have been performed in three different geometries and in a photon energy range suitable with SPECT and PET applications. The experimental results identify the CRY-018 as an Yttrium and Silicon mixture and the CRY-019 with as Lutetium and Silicon one. Moreover a light yield of about 45% of LaBr3 one, was obtained for both the CRY-018 and CRY-019. This is one of the higher light yield between most of the scintillation crystals usually used in nuclear medicine. Both crystals are characterized by a non-proportionality in the pulse height linearity response. Energy resolutions of 7.4% for CRY-018 and 8.4% for CRY-019 at 661 keV, have been measured. The intrinsic component of the energy resolution has been esteemed for all three scintillators. An intrinsic detection efficiency of about 45% at 122 keV for CRY-018 and 14% at 661 keV for CRY-019 has been measured. Compared with LaBr3:Ce efficiency, which is highly deteriorated by the coating required by the hygroscopicity, CRY-018 and CRY-019 are really interesting considering that these two samples are only 6 mm thick. Crytur's crystals seem to be suitable for nuclear medicine applications.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 13
Typ av publikation
tidskriftsartikel (12)
konferensbidrag (1)
Typ av innehåll
refereegranskat (11)
övrigt vetenskapligt/konstnärligt (2)
Författare/redaktör
Ridolfi, Elena (3)
Guida, M. (3)
Schmidt, H. (2)
Hansson, J. (2)
Manney, G. (2)
Strong, K. (2)
visa fler...
Bernath, P. F. (2)
Brohede, Samuel, 197 ... (2)
McElroy, C. T. (2)
Walker, K. A. (2)
Di Baldassarre, Giul ... (2)
Mazzoleni, Maurizio (2)
Alfonso, L. (2)
Schneider, M. (1)
Krause, Stefan (1)
Russo, F. (1)
Sharma, P. (1)
Kroemer, G (1)
Tian, Z. (1)
Nylander, Tommy (1)
Santee, M. L. (1)
Richter, A. (1)
Batchelor, R. L. (1)
Daffer, W.H. (1)
Drummond, J. R. (1)
Goutail, F. (1)
Hendrick, F. (1)
McLinden, C. A. (1)
Kiessling, R (1)
Masucci, G (1)
Imai, K (1)
Seibert, Jan (1)
Lötvall, Jan, 1956 (1)
Ivanov, Alexander R. (1)
Van Loon, Anne F. (1)
Kalantari, Zahra (1)
Xiao, W (1)
Milz, Mathias (1)
Taylor, J. (1)
Linden, A (1)
Destouni, Georgia (1)
Castelletti, Andrea (1)
McDonnell, Jeffrey J ... (1)
Arheimer, Berit (1)
Zou, J (1)
Alonso Vicario, S. (1)
Bhamidipati, S. (1)
Gharesifard, M. (1)
Pandolfo, C. (1)
Beven, Keith (1)
visa färre...
Lärosäte
Karolinska Institutet (4)
Uppsala universitet (3)
Luleå tekniska universitet (3)
Kungliga Tekniska Högskolan (2)
Lunds universitet (2)
Chalmers tekniska högskola (2)
visa fler...
Göteborgs universitet (1)
Stockholms universitet (1)
Sveriges Lantbruksuniversitet (1)
visa färre...
Språk
Engelska (13)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (6)
Teknik (6)
Medicin och hälsovetenskap (1)
Samhällsvetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy