SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Atchison David A.)
 

Sökning: WFRF:(Atchison David A.) > (2022) > Adaptive optics vis...

Adaptive optics visual simulators : a review of recent optical designs and applications [Invited]

Marcos, Susana (författare)
Univ Rochester, Inst Opt, Ctr Visual Sci, New York, NY 14642 USA.;Univ Rochester, Flaum Eye Inst, New York, NY 14642 USA.
Artal, Pablo (författare)
Univ Murcia, Lab Opt, Campus Univ Espinardo, Murcia 30100, Spain.
Atchison, David A. (författare)
Queensland Univ Technol, Ctr Vis & Eye Res, Brisbane, Qld 4059, Australia.
visa fler...
Hampson, Karen (författare)
Univ Manchester, Dept Optometry, Manchester M13 9PL, England.
Legras, Richard (författare)
Univ Paris Saclay, ENS Paris Saclay, LuMIn, CNRS,CentraleSupelec, F-91400 Orsay, France.
Lundström, Linda (författare)
KTH,Biomedicinsk fysik och röntgenfysik
Yoon, Geunyoung (författare)
Univ Houston, Coll Optometry, Houston, TX 77004 USA.
visa färre...
Univ Rochester, Inst Opt, Ctr Visual Sci, New York, NY 14642 USA;Univ Rochester, Flaum Eye Inst, New York, NY 14642 USA. Univ Murcia, Lab Opt, Campus Univ Espinardo, Murcia 30100, Spain. (creator_code:org_t)
Optica Publishing Group, 2022
2022
Engelska.
Ingår i: Biomedical Optics Express. - : Optica Publishing Group. - 2156-7085. ; 13:12, s. 6508-6532
  • Forskningsöversikt (refereegranskat)
Abstract Ämnesord
Stäng  
  • In their pioneering work demonstrating measurement and full correction of the eye's optical aberrations, Liang, Williams and Miller, [JOSA A 14, 2884 (1997)] showed improvement in visual performance using adaptive optics (AO). Since then, AO visual simulators have been developed to explore the spatial limits to human vision and as platforms to test non-invasively optical corrections for presbyopia, myopia, or corneal irregularities. These applications have allowed new psychophysics bypassing the optics of the eye, ranging from studying the impact of the interactions of monochromatic and chromatic aberrations on vision to neural adaptation. Other applications address new paradigms of lens designs and corrections of ocular errors. The current paper describes a series of AO visual simulators developed in laboratories around the world, key applications, and current trends and challenges. As the field moves into its second quarter century, new available technologies and a solid reception by the clinical community promise a vigorous and expanding use of AO simulation in years to come.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Oftalmologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Ophthalmology (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
for (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy