SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Bloch M) srt2:(1995-1999)"

Sökning: WFRF:(Bloch M) > (1995-1999)

  • Resultat 1-10 av 10
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Axelsson, L., et al. (författare)
  • Study of the unbound nucleus 11N by elastic resonance scattering
  • 1996
  • Ingår i: Physical Review C (Nuclear Physics). - 0556-2813 .- 2469-9985 .- 2469-9993. ; 54:4, s. 1511-1514
  • Tidskriftsartikel (refereegranskat)abstract
    • Resonances in the unbound nucleus 11N have been studied, using the resonance scattering reaction 10C+p. The data give evidence for three states above the 10C+p threshold with energies 1.30, 2.04, and 3.72 MeV. These states can be interpreted, in a potential-model analysis, as the ground state and the first two excited states with spin-parity 1 / 2+, 1 / 2-, and 5 / 2+ arising from the shell-model orbitals 1s1 / 2, 0p1 / 2, and 0d5 / 2. A narrow state superposed on a broad structure found at higher energy could be interpreted as the mirror state of the 3 / 2- in 11Be shifted down in energy. This shift would suggest a large radius of the potential.
  •  
2.
  •  
3.
  •  
4.
  • Albrecht, E, et al. (författare)
  • Operation, optimisation, and performance of the DELPHI RICH detectors
  • 1999
  • Ingår i: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT. - : ELSEVIER SCIENCE BV. - 0168-9002. ; 433:1-2, s. 47-58
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • The Ring Imaging Cherenkov detectors of DELPHI represent a large-scale particle identification system which covers almost the full angular acceptance of DELPHI. The combination of liquid and gas radiators (C4F10, C5F12, and C6F14) provides particle identi
  •  
5.
  •  
6.
  • Adam, W, et al. (författare)
  • Current achievements of the DELPHI ring imaging Cherenkov detector
  • 1996
  • Ingår i: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT. - : ELSEVIER SCIENCE BV. - 0168-9002. ; 371:1-2, s. 12-15
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • The DELPHI experiment has already collected 2.5 million Z(0) decays with the ring imaging Cherenkov detector (RICH) operational. This detector, covering most of the solid angle, is designed to perform pi/K separation from 0.8 to 20 GeV/c and K/p separatio
  •  
7.
  •  
8.
  • Almqvist, E, et al. (författare)
  • Risk reversals in predictive testing for Huntington disease.
  • 1997
  • Ingår i: American Journal of Human Genetics. - : Elsevier BV. - 0002-9297 .- 1537-6605. ; 61:4, s. 945-52
  • Tidskriftsartikel (refereegranskat)abstract
    • The first predictive testing for Huntington disease (HD) was based on analysis of linked polymorphic DNA markers to estimate the likelihood of inheriting the mutation for HD. Limits to accuracy included recombination between the DNA markers and the mutation, pedigree structure, and whether DNA samples were available from family members. With direct tests for the HD mutation, we have assessed the accuracy of results obtained by linkage approaches when requested to do so by the test individuals. For six such individuals, there was significant disparity between the tests. Three went from a decreased risk to an increased risk, while in another three the risk was decreased. Knowledge of the potential reasons for these changes in results and impact of these risk reversals on both patients and the counseling team can assist in the development of strategies for the prevention and, where necessary, management of a risk reversal in any predictive testing program.
  •  
9.
  • Almqvist, E W, et al. (författare)
  • A worldwide assessment of the frequency of suicide, suicide attempts, or psychiatric hospitalization after predictive testing for Huntington disease.
  • 1999
  • Ingår i: American Journal of Human Genetics. - 0002-9297 .- 1537-6605. ; 64:5, s. 1293-304
  • Tidskriftsartikel (refereegranskat)abstract
    • Prior to the implementation of predictive-testing programs for Huntington disease (HD), significant concern was raised concerning the likelihood of catastrophic events (CEs), particularly in those persons receiving an increased-risk result. We have investigated the frequency of CEs-that is, suicide, suicide attempt, and psychiatric hospitalization-after an HD predictive-testing result, through questionnaires sent to predictive-testing centers worldwide. A total of 44 persons (0.97%) in a cohort of 4,527 test participants had a CE: 5 successful suicides, 21 suicide attempts, and 18 hospitalizations for psychiatric reasons. All persons committing suicide had signs of HD, whereas 11 (52.4%) of 21 persons attempting suicide and 8 (44.4%) of 18 who had a psychiatric hospitalization were symptomatic. A total of 11 (84.6%) of 13 asymptomatic persons who experienced a CE during the first year after HD predictive testing received an increased-risk result. Factors associated with an increased risk of a CE included (a) a psychiatric history
  •  
10.
  • Vatnitsky, S, et al. (författare)
  • Proton dosimetry intercomparison based on the ICRU report 59 protocol
  • 1999
  • Ingår i: Radiotherapy and Oncology. - 0167-8140 .- 1879-0887. ; 51:3, s. 273-279
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND AND PURPOSE:A new protocol for calibration of proton beams was established by the ICRU in report 59 on proton dosimetry. In this paper we report the results of an international proton dosimetry intercomparison, which was held at Loma Linda University Medical Center. The goals of the intercomparison were, first, to estimate the level of consistency in absorbed dose delivered to patients if proton beams at various clinics were calibrated with the new ICRU protocol, and second, to evaluate the differences in absorbed dose determination due to differences in 60Co-based ionization chamber calibration factors.MATERIALS AND METHODS:Eleven institutions participated in the intercomparison. Measurements were performed in a polystyrene phantom at a depth of 10.27 cm water equivalent thickness in a 6-cm modulated proton beam with an accelerator energy of 155 MeV and an incident energy of approximately 135 MeV. Most participants used ionization chambers calibrated in terms of exposure or air kerma. Four ionization chambers had 60Co-based calibration in terms of absorbed dose-to-water. Two chambers were calibrated in a 60Co beam at the NIST both in terms of air kerma and absorbed dose-to-water to provide a comparison of ionization chambers with different calibrations.RESULTS:The intercomparison showed that use of the ICRU report 59 protocol would result in absorbed doses being delivered to patients at their participating institutions to within +/-0.9% (one standard deviation). The maximum difference between doses determined by the participants was found to be 2.9%. Differences between proton doses derived from the measurements with ionization chambers with N(K)-, or N(W) - calibration type depended on chamber type.CONCLUSIONS:Using ionization chambers with 60Co calibration factors traceable to standard laboratories and the ICRU report 59 protocol, a distribution of stated proton absorbed dose is achieved with a difference less than 3%. The ICRU protocol should be adopted for clinical proton beam calibration. A comparison of proton doses derived from measurements with different chambers indicates that the difference in results cannot be explained only by differences in 60Co calibration factors.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 10

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy