SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Canepa A.) srt2:(2005-2009)"

Sökning: WFRF:(Canepa A.) > (2005-2009)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Schael, S, et al. (författare)
  • Precision electroweak measurements on the Z resonance
  • 2006
  • Ingår i: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 427:5-6, s. 257-454
  • Forskningsöversikt (refereegranskat)abstract
    • We report on the final electroweak measurements performed with data taken at the Z resonance by the experiments operating at the electron-positron colliders SLC and LEP. The data consist of 17 million Z decays accumulated by the ALEPH, DELPHI, L3 and OPAL experiments at LEP, and 600 thousand Z decays by the SLID experiment using a polarised beam at SLC. The measurements include cross-sections, forward-backward asymmetries and polarised asymmetries. The mass and width of the Z boson, m(Z) and Gamma(Z), and its couplings to fermions, for example the p parameter and the effective electroweak mixing angle for leptons, are precisely measured: m(Z) = 91.1875 +/- 0.0021 GeV, Gamma(Z) = 2.4952 +/- 0.0023 GeV, rho(l) = 1.0050 +/- 0.0010, sin(2)theta(eff)(lept) = 0.23153 +/- 0.00016. The number of light neutrino species is determined to be 2.9840 +/- 0.0082, in agreement with the three observed generations of fundamental fermions. The results are compared to the predictions of the Standard Model (SM). At the Z-pole, electroweak radiative corrections beyond the running of the QED and QCD coupling constants are observed with a significance of five standard deviations, and in agreement with the Standard Model. Of the many Z-pole measurements, the forward-backward asymmetry in b-quark production shows the largest difference with respect to its SM expectation, at the level of 2.8 standard deviations. Through radiative corrections evaluated in the framework of the Standard Model, the Z-pole data are also used to predict the mass of the top quark, m(t) = 173(+10)(+13) GeV, and the mass of the W boson, m(W) = 80.363 +/- 0.032 GeV. These indirect constraints are compared to the direct measurements, providing a stringent test of the SM. Using in addition the direct measurements of m(t) and m(W), the mass of the as yet unobserved SM Higgs boson is predicted with a relative uncertainty of about 50% and found to be less than 285 GeV at 95% confidence level. (c) 2006 Elsevier B.V. All rights reserved.
  •  
2.
  • Marotti, R.E., et al. (författare)
  • Characterization of ZnO and ZnO : Al thin films deposited by the sol–gel dip-coating technique
  • 2008
  • Ingår i: Thin Solid Films. - : Elsevier. - 0040-6090 .- 1879-2731. ; 517:3, s. 1077-1080
  • Tidskriftsartikel (refereegranskat)abstract
    • Nanocrystalline zinc oxide films have been obtained by the sol–gel process. The films were deposited from precursor solutions by dip-coating on quartz substrates, and subsequently transformed into nanocrystalline pure or aluminium-doped ZnO films after a thermal treatment. The film microstructure and composition characterization was studied by X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS). The optical properties were studied by transmittance spectroscopy. The water adsorption energy was measured by temperature programmed desorption (TPD) in the range 90–700 K. The optical transmittance in the UV region gives bandgap energy values of 3.27 eV for undoped samples, and higher than 3.30 eV for the Al-doped ones. The increase in bandgap energy in Al-doped samples may be explained by band-filling effects. The band edge absorption coefficient increases monotonically for the Al-doped samples but has a shoulder for the undoped ones, which may be assigned to room-temperature excitonic absorption.
  •  
3.
  • Lindblad, YT, et al. (författare)
  • Hyperinsulinemia and insulin resistance, early cardiovascular risk factors in children with chronic kidney disease
  • 2008
  • Ingår i: Blood purification. - : S. Karger AG. - 1421-9735 .- 0253-5068. ; 26:6, s. 518-525
  • Tidskriftsartikel (refereegranskat)abstract
    • <i>Background/Aims:</i> Pediatric chronic kidney disease (CKD) is associated with increased risk of cardiovascular disease. Still, hyperinsulinemia and insulin resistance, common cardiovascular risk factors, are not extensively investigated in children with CKD. We hypothesize that insulin abnormalities are present also in pediatric mild to moderate CKD, and associated with inflammation and malnutrition. <i>Methods:</i> We enrolled 26 children with CKD, and 34 healthy controls for analyses of blood samples and body composition. Insulin resistance was assessed using the homeostasis model assessment for insulin resistance (HOMA-IR). <i>Results:</i> The patients had higher insulin levels and HOMA-IR compared to the controls (p < 0.01 and p < 0.005), and they correlated inversely with estimated glomerular filtration rate (rho = –0.52, p < 0.01; rho = –0.37, p = 0.08). No association was found with inflammation or malnutrition. <i>Conclusion:</i> High insulin levels and HOMA-IR appear to be common in pediatric CKD patients, already in mild to moderate renal failure. We hypothesize that hyperinsulinemia and insulin resistance alone might be important risk factors for cardiovascular disease in children with CKD.
  •  
4.
  • Rich, Rebecca L., et al. (författare)
  • A global benchmark study using affinity-based biosensors
  • 2009
  • Ingår i: Analytical Biochemistry. - : Elsevier BV. - 0003-2697 .- 1096-0309. ; 386:2, s. 194-216
  • Tidskriftsartikel (refereegranskat)abstract
    • To explore the variability in biosensor studies, 150 participants from 20 countries were given the same protein samples and asked to determine kinetic rate constants for the interaction. We chose a protein system that was amenable to analysis using different biosensor platforms as well as by users of different expertise levels. The two proteins (a 50-kDa Fab and a 60-kDa glutathione S-transferase [GST] antigen) form a relatively high-affinity complex, so participants needed to optimize several experimental parameters, including ligand immobilization and regeneration conditions as well as analyte concentrations and injection/dissociation times. Although most participants collected binding responses that could be fit to yield kinetic parameters, the quality of a few data sets could have been improved by optimizing the assay design. Once these outliers were removed, the average reported affinity across the remaining panel of participants was 620 pM with a standard deviation of 980 pM. These results demonstrate that when this biosensor assay was designed and executed appropriately, the reported rate constants were consistent, and independent of which protein was immobilized and which biosensor was used.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy