SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Gohlke Baerwolf Christa) srt2:(2014)"

Sökning: WFRF:(Gohlke Baerwolf Christa) > (2014)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Greve, Anders M., et al. (författare)
  • Stroke in Patients With Aortic Stenosis The Simvastatin and Ezetimibe in Aortic Stenosis Study
  • 2014
  • Ingår i: Stroke. - : American Heart Association. - 0039-2499 .- 1524-4628. ; 45:7, s. 1939-1946
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and Purpose-There are limited data on risk stratification of stroke in aortic stenosis. This study examined predictors of stroke in aortic stenosis, the prognostic implications of stroke, and how aortic valve replacement (AVR) with or without concomitant coronary artery bypass grafting influenced the predicted outcomes. Methods-Patients with mild-to-moderate aortic stenosis enrolled in the Simvastatin and Ezetimibe in Aortic Stenosis (SEAS) study. Diabetes mellitus, known atherosclerotic disease, and oral anticoagulation were exclusion criteria. Ischemic stroke was the primary end point, and poststroke survival a secondary outcome. Cox models treating AVR as a time-varying covariate were adjusted for atrial fibrillation and congestive heart failure, hypertension, age >= 75 years, diabetes mellitus, stroke/transient ischemic attack, vascular disease, age 65-74 years and female sex (CHA(2)DS(2)-VASc) scores. Results-One thousand five hundred nine patients were followed for 4.3 +/- 0.8 years (6529 patient-years). Rates of stroke were 5.6 versus 21.8 per 1000 patient-years pre- and post-AVR; 429 (28%) underwent AVR and 139 (9%) died. Atrial fibrillation (hazard ratio [HR], 2.7; 95% confidence interval [CI], 1.1-6.6), CHA(2)DS(2)-VASc score (HR 1.4 per unit; 95% CI, 1.1-1.8), diastolic blood pressure (HR, 1.4 per 10 mm Hg; 95% CI, 1.1-1.8), and AVR with concomitant coronary artery bypass grafting (HR, 3.2; 95% CI, 1.4-7.2, all P <= 0.026) were independently associated with stroke. Incident stroke predicted death (HR, 8.1; 95% CI, 4.7-14.0; P<0.001). Conclusions-In patients with aortic stenosis not prescribed oral anticoagulation, atrial fibrillation, AVR with concomitant coronary artery bypass grafting, and CHA(2)DS(2)-VASc score were the major predictors of stroke. Incident stroke was strongly associated with mortality.
  •  
2.
  • Greve, Anders M., et al. (författare)
  • Usefulness of the electrocardiogram in predicting cardiovascular mortality in asymptomatic adults with aortic stenosis (from the Simvastatin and Ezetimibe in Aortic Stenosis study)
  • 2014
  • Ingår i: American Journal of Cardiology. - : Elsevier. - 0002-9149 .- 1879-1913. ; 114:5, s. 751-756
  • Tidskriftsartikel (refereegranskat)abstract
    • Hypertension and coronary heart disease are common in aortic stenosis (AS) and may impair prognosis for similar AS severity. Different changes in the electrocardiogram may be reflective of the separate impacts of AS, hypertension, and coronary heart disease, which could lead to enhanced risk stratification in AS. The aim of this study was therefore to examine if combining prognostically relevant electrocardiographic (ECG) findings improves prediction of cardiovascular mortality in asymptomatic AS. All patients with baseline electrocardiograms in the SEAS study were included. The primary end point was cardiovascular death. Backward elimination (p > 0.01) identified heart rate, Q waves, and Cornell voltage-duration product as independently associated with cardiovascular death. Multivariate logistic and Cox regression models were used to evaluate if these 3 ECG variables improved prediction of cardiovascular death. In 1,473 patients followed for a mean of 4.3 years (6,362 patient-years of follow-up), 70 cardiovascular deaths (5%) occurred. In multivariate analysis, heart rate (hazard ratio [FIR] 1.5 per 11.2 minute(-1) [1 SD], 95% confidence interval [CI] 1.2 to 1.8), sum of Q-wave amplitude (HR 1.3 per 2.0 nun [1 SD], 95% CI 1.1 to 1.6), and Cornell voltage-duration product (FIR 1.4 per 763 mm x ms [1 SD], 95% CI 1.2 to 1.7) remained independently associated with cardiovascular death. Combining the prognostic information contained in each of the 3 ECG variables improved integrated discrimination for prediction of cardiovascular death by 2.5%, net reclassification by 14.3%, and area under the curve by 0.06 (all p <= 0.04) beyond other important risk factors. ECG findings add incremental predictive information for cardiovascular mortality in asymptomatic patients with AS.
  •  
3.
  • Jander, Nikolaus, et al. (författare)
  • Indexing aortic valve area by body surface area increases the prevalence of severe aortic stenosis
  • 2014
  • Ingår i: Heart. - : BMJ. - 1355-6037 .- 1468-201X. ; 100:1, s. 28-33
  • Tidskriftsartikel (refereegranskat)abstract
    • Background To account for differences in body size in patients with aortic stenosis, aortic valve area (AVA) is divided by body surface area (BSA) to calculate indexed AVA (AVA(index)). Cut-off values for severe stenosis are <1.0cm(2) for AVA and <0.6cm(2)/m(2) for AVA(index). Objective To investigate the influence of indexation on the prevalence of severe aortic stenosis and on the predictive accuracy regarding clinical outcome. Methods Echocardiographic and anthropometric data from a retrospective cohort of 2843 patients with aortic stenosis (jet velocity >2.5m/s) and from 1525 patients prospectively followed in the simvastatin and ezetimibe in aortic stenosis (SEAS) trial were analysed. Results The prevalence of severe stenosis increased with the AVA(index) criterion compared to AVA from 71% to 80% in the retrospective cohort, and from 29% to 44% in SEAS (both p<0.001). Overall, the predictive accuracy for aortic valve events was virtually identical for AVA and AVA(index) in the SEAS population (mean follow-up of 46months; area under the receiver operating characteristic curve: 0.67 (95% CI 0.64 to 0.70) vs 0.68 (CI 0.65 to 0.71) (NS). However, 213 patients additionally categorised as severe by AVA(index) experienced significantly less valve related events than those fulfilling only the AVA criterion (p<0.001). Conclusions Indexing AVA by BSA (AVA(index)) significantly increases the prevalence of patients with criteria for severe stenosis by including patients with a milder degree of the disease without improving the predictive accuracy for aortic valve related events.
  •  
4.
  • Jander, Nikolaus, et al. (författare)
  • Velocity ratio predicts outcomes in patients with low gradient severe aortic stenosis and preserved EF
  • 2014
  • Ingår i: Heart. - : BMJ. - 1355-6037 .- 1468-201X. ; 100:24, s. 1946-1953
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective To evaluate the usefulness of velocity ratio (VR) in patients with low gradient severe aortic stenosis (LGSAS) and preserved EF.Background LGSAS despite preserved EF represents a clinically challenging entity. Reliance on mean pressure gradient (MPG) may underestimate stenosis severity as has been reported in the context of paradoxical low flow, LGSAS. On the other hand, grading of stenosis severity by aortic valve area (AVA) may overrate stenosis severity due to erroneous underestimation of LV outflow tract (LVOT) diameter, small body size or inconsistencies in cut-off values for severe stenosis. We hypothesised that VR may have conceptual advantages over MPG and AVA, predict clinical outcomes and thereby be useful in the management of patients with LGSAS.Methods Patients from the prospective Simvastatin and Ezetimibe in Aortic Stenosis (SEAS) study with an AVA<1.0 cm(2), MPG <= 40 mm Hg and EF >= 55% and asymptomatic at baseline were stratified according to VR with a cut-off value of 0.25. Outcomes were evaluated according to aortic valve-related events and cardiovascular death.Results Of 435 patients with LGSAS, 197 (45%) had VR<0.25 suggesting severe and 238 (55%) had VR >= 0.25 suggesting non-severe stenosis. Aortic valve-related events (mean follow-up 42 +/- 14 months) were more frequent in patients with VR<0.25 (57% vs 41%; p<0.001) as was cardiovascular death within the first 24 months (p<0.05). In multivariable Cox regression analysis, MPG was the strongest independent predictor of aortic valve events (p<0.001) followed by VR (p<0.02). Adjusting AVA by VR increased predictive accuracy for aortic valve events (area under the receiver operating curve 0.62 (95% CI 0.57 to 0.67) vs 0.56 (95% CI 0.51 to 0.61) for AVA, p=0.02) with net reclassification improvement calculated at 0.36 (95% CI 0.17 to 0.54, p<0.001). VR did not improve the prediction of clinical events by MPG.Conclusions In the difficult setting of LGSAS, VR shows a strong association with valve-related events and - although not outperforming MPG-may be particularly useful in guiding clinical management.
  •  
5.
  • Minners, Jan, et al. (författare)
  • Adjusting parameters of aortic valve stenosis severity by body size
  • 2014
  • Ingår i: Heart. - : BMJ. - 1355-6037 .- 1468-201X. ; 100:13, s. 1024-1030
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Adjustment of cardiac dimensions by measures of body size appears intuitively convincing and in patients with aortic stenosis, aortic valve area (AVA) is commonly adjusted by body surface area (BSA). However, there is little evidence to support such an approach. Objective To identify the adequate measure of body size for the adjustment of aortic stenosis severity. Methods Parameters of aortic stenosis severity (jet velocity, mean pressure gradient (MPG) and AVA) and measures of body size (height, weight, BSA and body mass index (BMI)) were analysed in 2843 consecutive patients with aortic stenosis (jet velocity >= 2.5 m/s) and related to outcomes in a second cohort of 1525 patients from the Simvastatin/Ezetimibe in Aortic Stenosis (SEAS) study. Results Whereas jet velocity and MPG were independent of body size, AVA was significantly correlated with height, weight, BSA and BMI (Pearson correlation coefficient (r) 0.319, 0.281, 0.317 and 0.126, respectively, all p<0.001) to the effect that larger patients presented with larger AVA (less severe stenosis). Of the anthropometric measures used for linear adjustment, BSA was most effective in eliminating the correlation between AVA and body size (r=0.007), rivalled only by allometric (non-linear) models, findings that are confirmed in 1525 prospectively followed patients from the SEAS study. Predictive accuracy for aortic valve events and cardiovascular death during 46 months of follow-up was unchanged by adjusting AVA, regardless of measure of body size (area under the receiver operating curve for AVA 0.72 (CI 0.58 to 0.87) versus, for example, AVA/BSA 0.75 (CI 0.61 to 0.88), p=0.22). Conclusions In the assessment of aortic stenosis, linear adjustment of AVA by BSA improves comparability between patients with diverging body size without, however, increasing the predictive accuracy for clinical events in a population with mild to moderate stenosis.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy