SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Kilbourne Caroline A.)
 

Sökning: WFRF:(Kilbourne Caroline A.) > (2019) > Poisson vs. Gaussia...

Poisson vs. Gaussian statistics for sparse X-ray data : Application to the soft X-ray spectrometer

Yamada, Shinya (författare)
Tokyo Metropolitan Univ, Dept Phys, 1-1 Minami Osawa, Hachioji, Tokyo 1920397, Japan.
Axelsson, Magnus (författare)
KTH,Partikel- och astropartikelfysik,Tokyo Metropolitan Univ, Dept Phys, 1-1 Minami Osawa, Hachioji, Tokyo 1920397, Japan.
Ishisaki, Yoshitaka (författare)
Tokyo Metropolitan Univ, Dept Phys, 1-1 Minami Osawa, Hachioji, Tokyo 1920397, Japan.
visa fler...
Konami, Saori (författare)
Tokyo Metropolitan Univ, Dept Phys, 1-1 Minami Osawa, Hachioji, Tokyo 1920397, Japan.
Takemura, Nozomi (författare)
Tokyo Metropolitan Univ, Dept Phys, 1-1 Minami Osawa, Hachioji, Tokyo 1920397, Japan.
Kelley, Richard L. (författare)
NASA, Goddard Space Flight Ctr, 8800 Greenbelt Rd, Greenbelt, MD 20771 USA.;Lawrence Livermore Natl Lab, 7000 East Ave, Livermore, CA 94550 USA.
Kilbourne, Caroline A. (författare)
NASA, Goddard Space Flight Ctr, 8800 Greenbelt Rd, Greenbelt, MD 20771 USA.;Lawrence Livermore Natl Lab, 7000 East Ave, Livermore, CA 94550 USA.
Leutenegger, Maurice A. (författare)
NASA, Goddard Space Flight Ctr, 8800 Greenbelt Rd, Greenbelt, MD 20771 USA.;Lawrence Livermore Natl Lab, 7000 East Ave, Livermore, CA 94550 USA.
Porter, F. Scott (författare)
NASA, Goddard Space Flight Ctr, 8800 Greenbelt Rd, Greenbelt, MD 20771 USA.;Lawrence Livermore Natl Lab, 7000 East Ave, Livermore, CA 94550 USA.
Eckart, Megan E. (författare)
Yale Univ, Dept Phys, POB 208120, New Haven, CT 06520 USA.
Szymkowiak, Andrew (författare)
Yale Univ, Dept Phys, POB 208120, New Haven, CT 06520 USA.
visa färre...
Tokyo Metropolitan Univ, Dept Phys, 1-1 Minami Osawa, Hachioji, Tokyo 1920397, Japan Partikel- och astropartikelfysik (creator_code:org_t)
2019-07-19
2019
Engelska.
Ingår i: Publications of the Astronomical Society of Japan. - : OXFORD UNIV PRESS. - 0004-6264 .- 2053-051X. ; 71:4
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Reliable results when fitting X-ray data require proper consideration of the statistics involved. We probe the impact of Gaussian versus Poisson statistics at low count levels using both the standard chi(2) method and maximum likelihood based on Poisson studied and quantified through simulated spectra with known properties. We then test the results through analysis of Mn K alpha calibration data taken with the flight spare microcalorimeter for the Hitomi soft X-ray spectrometer. Through comparison with simulations, our results show that the chi(2) method tends to give overly optimistic estimates of the detector energy resolution, in particular when there are few counts. Given an energy resolution of similar to 5eV and a line with about 100 photons, the line width becomes similar to 10% lower in the chi(2) method than in Poisson statistics. This is a consequence of the uncertainties being dominated by counting statistics, and therefore highlights the need to choose the appropriate fit statistic.

Ämnesord

NATURVETENSKAP  -- Fysik -- Astronomi, astrofysik och kosmologi (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Astronomy, Astrophysics and Cosmology (hsv//eng)

Nyckelord

instrumentation: detectors
methods: data analysis
methods: statistical

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy