SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Lambert C) srt2:(2005-2009)"

Sökning: WFRF:(Lambert C) > (2005-2009)

  • Resultat 1-10 av 20
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Strong, K., et al. (författare)
  • Validation of ACE-FTS N2O measurements
  • 2008
  • Ingår i: Atmospheric Chemistry and Physics. - : Copernicus GmbH. - 1680-7316 .- 1680-7324. ; 8, s. 4759-4786
  • Tidskriftsartikel (refereegranskat)abstract
    • The Atmospheric Chemistry Experiment (ACE), also known as SCISAT, was launched on 12 August 2003, carrying two instruments that measure vertical profiles of atmospheric constituents using the solar occultation technique. One of these instruments, the ACE Fourier Transform Spectrometer (ACE-FTS), is measuring volume mixing ratio (VMR) profiles of nitrous oxide (N2O) from the upper troposphere to the lower mesosphere at a vertical resolution of about 3–4 km. In this study, the quality of the ACE-FTS version 2.2 N2O data is assessed through comparisons with coincident measurements made by other satellite, balloon-borne, aircraft, and ground-based instruments. These consist of vertical profile comparisons with the SMR, MLS, and MIPAS satellite instruments, multiple aircraft flights of ASUR, and single balloon flights of SPIRALE and FIRS-2, and partial column comparisons with a network of ground-based Fourier Transform InfraRed spectrometers (FTIRs). Between 6 and 30 km, the mean absolute differences for the satellite comparisons lie between −42 ppbv and +17 ppbv, with most within ±20 ppbv. This corresponds to relative deviations from the mean that are within ±15%, except for comparisons with MIPAS near 30 km, for which they are as large as 22.5%. Between 18 and 30 km, the mean absolute differences for the satellite comparisons are generally within ±10 ppbv. From 30 to 60 km, the mean absolute differences are within ±4 ppbv, and are mostly between −2 and +1 ppbv. Given the small N2O VMR in this region, the relative deviations from the mean are therefore large at these altitudes, with most suggesting a negative bias in the ACE-FTS data between 30 and 50 km. In the comparisons with the FTIRs, the mean relative differences between the ACE-FTS and FTIR partial columns (which cover a mean altitude range of 14 to 27 km) are within ±5.6% for eleven of the twelve contributing stations. This mean relative difference is negative at ten stations, suggesting a small negative bias in the ACE-FTS partial columns over the altitude regions compared. Excellent correlation (R=0.964) is observed between the ACE-FTS and FTIR partial columns, with a slope of 1.01 and an intercept of −0.20 on the line fitted to the data.
  •  
3.
  • Lambert, A., et al. (författare)
  • Validation of the Aura Microwave Limb Sounder middle atmosphere water vapor and nitrous oxide measurements
  • 2007
  • Ingår i: Journal of Geophysical Research. - 0148-0227 .- 2156-2202. ; 112:D24
  • Tidskriftsartikel (refereegranskat)abstract
    • The quality of the version 2.2 (v2.2) middle atmosphere water vapor and nitrous oxide measurements from the Microwave Limb Sounder (MLS) on the Earth Observing System (EOS) Aura satellite is assessed. The impacts of the various sources of systematic error are estimated by a comprehensive set of retrieval simulations. Comparisons with correlative data sets from ground-based, balloon and satellite platforms operating in the UV/ visible, infrared and microwave regions of the spectrum are performed. Precision estimates are also validated, and recommendations are given on the data usage. The v2.2 H 2 O data have been improved over v1.5 by providing higher vertical resolution in the lower stratosphere and better precision above the stratopause. The single-profile precision is ∼0.2-0.3 ppmv (4-9%), and the vertical resolution is ∼3-4 km in the stratosphere. The precision and vertical resolution become worse with increasing height above the stratopause. Over the pressure range 0.1-0.01 hPa the precision degrades from 0.4 to 1.1 ppmv (6-34%), and the vertical resolution degrades to ∼12-16 km. The accuracy is estimated to be 0.2-0.5 ppmv (4-11%) for the pressure range 68-0.01 hPa. The scientifically useful range of the H 2 O data is from 316 to 0.002 hPa, although only the 82-0.002 hPa pressure range is validated here. Substantial improvement has been achieved in the v2.2 N 2 O data over v1.5 by reducing a significant low bias in the stratosphere and eliminating unrealistically high biased mixing ratios in the polar regions. The single-profile precision is ∼13-25 ppbv (7-38%), the vertical resolution is ∼4-6 km and the accuracy is estimated to be 3-70 ppbv (9-25%) for the pressure range 100-4.6 hPa. The scientifically useful range of the N 2 O data is from 100 to 1 hPa. Copyright 2007 by the American Geophysical Union.
  •  
4.
  • Santee, M.L., et al. (författare)
  • Validation of the Aura Microwave Limb Sounder HNO3 Measurements
  • 2007
  • Ingår i: Journal of Geophysical Research. - 0148-0227 .- 2156-2202. ; 112:D24
  • Tidskriftsartikel (refereegranskat)abstract
    • [1] We assess the quality of the version 2.2 (v2.2) HNO(3) measurements from the Microwave Limb Sounder (MLS) on the Earth Observing System Aura satellite. The MLS HNO(3) product has been greatly improved over that in the previous version (v1.5), with smoother profiles, much more realistic behavior at the lowest retrieval levels, and correction of a high bias caused by an error in one of the spectroscopy files used in v1.5 processing. The v2.2 HNO(3) data are scientifically useful over the range 215 to 3.2 hPa, with single-profile precision of similar to 0.7 ppbv throughout. Vertical resolution is 3-4 km in the upper troposphere and lower stratosphere, degrading to similar to 5 km in the middle and upper stratosphere. The impact of various sources of systematic uncertainty has been quantified through a comprehensive set of retrieval simulations. In aggregate, systematic uncertainties are estimated to induce in the v2.2 HNO(3) measurements biases that vary with altitude between +/- 0.5 and +/- 2 ppbv and multiplicative errors of +/- 5-15% throughout the stratosphere, rising to similar to +/- 30% at 215 hPa. Consistent with this uncertainty analysis, comparisons with correlative data sets show that relative to HNO(3) measurements from ground- based, balloon- borne, and satellite instruments operating in both the infrared and microwave regions of the spectrum, MLS v2.2 HNO(3) mixing ratios are uniformly low by 10-30% throughout most of the stratosphere. Comparisons with in situ measurements made from the DC-8 and WB-57 aircraft in the upper troposphere and lowermost stratosphere indicate that the MLS HNO(3) values are low in this region as well, but are useful for scientific studies (with appropriate averaging).
  •  
5.
  •  
6.
  •  
7.
  • Rueda, B., et al. (författare)
  • A large multicentre analysis of CTGF - 2945 promoter polymorphism does not confirm association with systemic sclerosis susceptibility or phenotype
  • 2009
  • Ingår i: Annals of the Rheumatic Diseases. - : BMJ. - 1468-2060 .- 0003-4967. ; 68:10, s. 1618-1620
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: To conduct a replication study to investigate whether the 2945 CTGF genetic variant is associated with systemic sclerosis (SSc) susceptibility or specific SSc phenotype. Methods: The study population comprised 1180 patients with SSc and 1784 healthy controls from seven independent case-control sets of European ancestry (Spanish, French, Dutch, German, British, Swedish and North American). The 2945 CTGF genetic variant was genotyped using a Taqman 59 allelic discrimination assay. Results: An independent association study showed in all the case-control cohorts no association of the CTGF 2945 polymorphism with SSc susceptibility. These findings were confirmed by a meta-analysis giving a pooled OR=1.12 (95% CI 0.99 to 1.25), p=0.06. Investigation of the possible contribution of the 2945 CTGF genetic variant to SSc phenotype showed that stratification according to SSc subtypes (limited or diffuse), selective autoantibodies (anti-topoisomerase I or anticentromere) or pulmonary involvement reached no statistically significant skewing. Conclusion: The results do not confirm previous findings and suggest that the CTGF 2945 promoter polymorphism does not play a major role in SSc susceptibility or clinical phenotype.
  •  
8.
  • Santee, M.L., et al. (författare)
  • Validation of the Aura Microwave Limb Sounder ClO Measurements
  • 2008
  • Ingår i: Journal of Geophysical Research. - 0148-0227 .- 2156-2202. ; 113:D15
  • Tidskriftsartikel (refereegranskat)abstract
    • We assess the quality of the version 2.2 (v2.2) ClO measurements from the Microwave Limb Sounder (MLS) on the Earth Observing System Aura satellite. The MLS v2.2 ClO data are scientifically useful over the range 100 to 1 hPa, with a single- profile precision of similar to 0.1 ppbv throughout most of the vertical domain. Vertical resolution is similar to 3-4 km. Comparisons with climatology and correlative measurements from a variety of different platforms indicate that both the amplitude and the altitude of the peak in the ClO profile in the upper stratosphere are well determined by MLS. The latitudinal and seasonal variations in the ClO distribution in the lower stratosphere are also well determined, but a substantial negative bias is present in both daytime and nighttime mixing ratios at retrieval levels below (i. e., pressures larger than) 22 hPa. Outside of the winter polar vortices, this negative bias can be eliminated by subtracting gridded or zonal mean nighttime values from the individual daytime measurements. In studies for which knowledge of lower stratospheric ClO mixing ratios inside the winter polar vortices to better than a few tenths of a ppbv is needed, however, day - night differences are not recommended and the negative bias must be corrected for by subtracting the estimated value of the bias from the individual measurements at each affected retrieval level.
  •  
9.
  • Beck, R., et al. (författare)
  • GPSDTN : Predictive velocity-enabled delay-tolerant networks for arctic research and sustainability
  • 2007
  • Ingår i: Second International Conference on Internet Monitoring and Protection (ICIMP 2007). - Los Alamitos, Calif : IEEE Computer Society Press. - 9780769529110
  • Konferensbidrag (refereegranskat)abstract
    • A Delay-Tolerant Network (DTN) is a necessity for communication nodes that may need to wait for long periods to form networks. The IETF Delay Tolerant Network Research Group is developing protocols to enable such networks for a broad variety of Earth and interplanetary applications. The Arctic would benefit from a predictive velocity-enabled version of DTN that would facilitate communications between sparse, ephemeral, often mobile and extremely power-limited nodes. We propose to augment DTN with power-aware, buffer-aware location- and time-based predictive routing for ad-hoc meshes to create networks that are inherently location and time (velocity) aware at the network level to support climate research, emergency services and rural education in the Arctic. On Earth, the primary source of location and universal time information for networks is the Global Positioning System (GPS). We refer to this Arctic velocity-enabled Delay-Tolerant Network protocol as "GPSDTN" accordingly. This paper describes our requirements analysis and general implementation strategy for GPSDTN to support Arctic research and sustainability efforts
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 20
Typ av publikation
tidskriftsartikel (14)
konferensbidrag (6)
Typ av innehåll
refereegranskat (18)
övrigt vetenskapligt/konstnärligt (2)
Författare/redaktör
Murtagh, Donal, 1959 (5)
Urban, Joachim, 1964 (5)
Kumar, R. (4)
Bernath, P. F. (4)
Walker, K. A. (4)
Ryk, C. (4)
visa fler...
Froidevaux, L. (4)
Livesey, N.J. (4)
Waters, J.W. (4)
LAMBERT, B (4)
Lambert, A (4)
Manney, G. L. (4)
Santee, M. L. (3)
Daffer, W.H. (3)
Boone, C. D. (3)
Read, W.G. (3)
Drouin, B. J. (3)
Kuttippurath, J. (3)
Toon, G.C. (3)
Hou, S. (2)
Fischer, H. (2)
Schneider, M. (2)
Larsson, P (2)
Strong, K. (2)
Hemminki, K (2)
Mellqvist, Johan, 19 ... (2)
Hesselstrand, Roger (2)
Lambert, Paul C. (2)
Berggren, P. (2)
Blumenstock, T. (2)
Mahieu, E. (2)
Robert, C (2)
Dupuy, E. (2)
Vonk, M. C. (2)
Höpfner, M. (2)
Wild, CP (2)
Catoire, V. (2)
Senten, C. (2)
Camps, M. T. (2)
Demoulin, P. (2)
Jin, J. J. (2)
Jucks, K. (2)
Kerzenmacher, T. E. (2)
Kleinböhl, A. (2)
McConnell, J. C. (2)
Piccolo, C. (2)
Tétard, C. (2)
Routledge, MN (2)
Van den Hoogen, F. H ... (2)
Lambert, N (2)
visa färre...
Lärosäte
Karolinska Institutet (6)
Chalmers tekniska högskola (5)
Lunds universitet (4)
Umeå universitet (2)
Uppsala universitet (2)
Göteborgs universitet (1)
visa fler...
Luleå tekniska universitet (1)
Stockholms universitet (1)
Linköpings universitet (1)
visa färre...
Språk
Engelska (19)
Odefinierat språk (1)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (5)
Medicin och hälsovetenskap (4)
Teknik (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy