SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Liu Hongde)
 

Sökning: WFRF:(Liu Hongde) > (2022) > Nonlinearity in mas...

Nonlinearity in mass spectrometry for quantitative multi-component gas analysis in reaction processes

Li, Rongbin (författare)
Univ Sci & Technol Beijing, Sch Met & Ecol Engn, Beijing 100083, Peoples R China.
Xia, Hongde (författare)
Chinese Acad Sci, Inst Engn Thermophys, Beijing 100190, Peoples R China.
Huang, Qian (författare)
Chinese Acad Sci, Inst Engn Thermophys, Beijing 100190, Peoples R China.
visa fler...
Hedström, Peter, 1955- (författare)
KTH,Materialvetenskap
Mu, Wangzhong, Dr. 1985- (författare)
KTH,Materialvetenskap
Wei, Kai (författare)
Chinese Acad Sci, Inst Engn Thermophys, Beijing 100190, Peoples R China.
Liu, Fengqin (författare)
Univ Sci & Technol Beijing, Sch Met & Ecol Engn, Beijing 100083, Peoples R China.
Zhao, Hongliang (författare)
Univ Sci & Technol Beijing, Sch Met & Ecol Engn, Beijing 100083, Peoples R China.
visa färre...
Univ Sci & Technol Beijing, Sch Met & Ecol Engn, Beijing 100083, Peoples R China Chinese Acad Sci, Inst Engn Thermophys, Beijing 100190, Peoples R China. (creator_code:org_t)
Elsevier BV, 2022
2022
Engelska.
Ingår i: Analytica Chimica Acta. - : Elsevier BV. - 0003-2670 .- 1873-4324. ; 1194, s. 339412-
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Quantitative mass spectrometry analysis for multi-component gas phase reaction processes is a typical multi-input and multi-output (MIMO) nonlinear problem. Conventional calibration and analytical methods that are based on the common hypothesis of linearity of the detected signal and gas parameters, could result in misjudgment of the reaction mechanism and inaccuracy in the determination of the reaction kinetics. In the present work, theoretical derivations based on equivalent characteristic spectrum analysis (ECSA (R)), discrete mode experiments and continuous mode experiments were performed, and the nonlinearity of mass spectrometry was confirmed. It is only possible to determine the physical parameters such as flow rate and/or concentrations of gases by properly handling the nonlinearity of mass spectrometry. In such case comprehensive reaction mechanisms and even the kinetics of the process can be accurately characterized. Well-handled nonlinear mass spectrometry analysis ensures a reliable and highly accurate identification for the multi-component gas phase reaction processes, and ensures high signal-to-noise ratio for detecting the small-flow gases at a wide range of carrier gas flow.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)

Nyckelord

Mass spectrometry
Multi-component gases
Reaction
Nonlinearity

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy