SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Mahteme Haile)
 

Sökning: WFRF:(Mahteme Haile) > (2005-2009) > Anundi Helena > Peritonectomy with ...

Peritonectomy with high voltage electrocautery generates higher levels of ultrafine smoke particles

Andréasson, Sara Näslund (författare)
Uppsala universitet,Kolorektalkirurgi
Anundi, Helena (författare)
Uppsala universitet,Institutionen för medicinska vetenskaper,Eva Vingård
Sahlberg, Bo (författare)
Uppsala universitet,Institutionen för medicinska vetenskaper,Eva Vingård
visa fler...
Ericsson, Claes-Gunnar (författare)
Uppsala universitet,Institutionen för medicinska vetenskaper,Eva Vingård
Wålinder, Robert (författare)
Uppsala universitet,Institutionen för medicinska vetenskaper,Eva Vingård
Enlund, G. (författare)
Påhlman, Lars (författare)
Uppsala universitet,Kolorektalkirurgi
Mahteme, Haile (författare)
Uppsala universitet,Kolorektalkirurgi
visa färre...
 (creator_code:org_t)
Elsevier BV, 2008
2008
Engelska.
Ingår i: European Journal of Surgical Oncology. - : Elsevier BV. - 0748-7983 .- 1532-2157. ; 35:7, s. 780-784
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND: To adequately perform peritonectomy, the use of an electrocautery device at a high voltage is recommended. The aim of this study was to analyse the amount of airborne and ultrafine particles (UFP) generated during peritonectomy and to compare this with standard colon and rectal cancer surgery (CRC). METHOD: UFP was measured approximately 2-3cm from the breathing area of the surgeon (personal sampling) and 3m from where the electrocautery smoke was generated (stationary sampling) from 14 consecutive peritonectomy procedures and 11 standard CRC resections. The sampling was by P-Trak UFP counter that has the capacity to detect particle size ranging from 0.02 to 1mum. RESULTS: The cumulative level of UFP of personal sampling in the peritonectomy group was higher (9.3x10(6)particle/ml/h (pt/ml/h)) than in the control group (4.8x10(5)pt/ml/h). A higher cumulative level of UFP in stationary sampling was observed in the PC group (2.6x10(6) pt/ml/h) than in the control group (3.9x10(4)pt/ml/h). CONCLUSION: Peritonectomy procedure with high voltage electrocautery generates elevated levels of UFP than standard CRC surgery does. The level of UFP produced by a peritonectomy is comparable to cigarette smoking. More efficient smoke evacuator systems are needed in order to reduce the levels of UFP generated during electrocautery surgery.

Nyckelord

Peritonectomy
Peritoneal carcinomatosis
Ultrafine particles
Occupational
MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy