SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Murat P.) srt2:(2010-2014)"

Sökning: WFRF:(Murat P.) > (2010-2014)

  • Resultat 1-10 av 13
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Aaltonen, T., et al. (författare)
  • Combination of Tevatron Searches for the Standard Model Higgs Boson in the W+W- Decay Mode
  • 2010
  • Ingår i: Physical Review Letters. - 0031-9007 .- 1079-7114. ; 104:6, s. 061802-
  • Tidskriftsartikel (refereegranskat)abstract
    • We combine searches by the CDF and D0 Collaborations for a Higgs boson decaying to W+W-. The data correspond to an integrated total luminosity of 4.8 (CDF) and 5.4 (D0) fb(-1) of p (p) over bar collisions at root s = 1.96 TeV at the Fermilab Tevatron collider. No excess is observed above background expectation, and resulting limits on Higgs boson production exclude a standard model Higgs boson in the mass range 162-166 GeV at the 95% C.L.
  •  
2.
  • Aaltonen, T., et al. (författare)
  • Combination of CDF and D0 measurements of the W boson helicity in top quark decays
  • 2012
  • Ingår i: Physical Review D. - 1550-7998 .- 1550-2368. ; 85:7, s. 071106-
  • Tidskriftsartikel (refereegranskat)abstract
    • We report the combination of recent measurements of the helicity of the W boson from top quark decay by the CDF and D0 collaborations, based on data samples corresponding to integrated luminosities of 2.7-5.4 fb(-1) of p (p) over bar collisions collected during Run II of the Fermilab Tevatron collider. Combining measurements that simultaneously determine the fractions of W bosons with longitudinal (f(0)) and right-handed (f(+)) helicities, we find f(0) = 0.722 +/- 0.081[+/- 0.062(stat) +/- 0.052(syst)] and f(+) = -0.033 +/- 0.046[+/- 0.034(stat) +/- 0.031(syst)]. Combining measurements where one of the helicity fractions is fixed to the value expected in the standard model, we find f(0) = 0.682 +/- 0.057[+/- 0.035(stat) +/- 0.046(syst)] for fixed f(+) and f(+) = -0.015 +/- 0.035[+/- 0.018(stat) +/- 0.030(syst)] for fixed f(0). The results are consistent with standard model expectations.
  •  
3.
  • Aaltonen, T., et al. (författare)
  • Evidence for a Particle Produced in Association with Weak Bosons and Decaying to a Bottom-Antibottom Quark Pair in Higgs Boson Searches at the Tevatron
  • 2012
  • Ingår i: Physical Review Letters. - 0031-9007 .- 1079-7114. ; 109:7, s. 071804-
  • Tidskriftsartikel (refereegranskat)abstract
    • We combine searches by the CDF and D0 Collaborations for the associated production of a Higgs boson with a W or Z boson and subsequent decay of the Higgs boson to a bottom-antibottom quark pair. The data, originating from Fermilab Tevatron p (p) over bar collisions at root s = 1.96 TeV, correspond to integrated luminosities of up to 9.7 fb(-1). The searches are conducted for a Higgs boson with mass in the range 100-150 GeV/c(2). We observe an excess of events in the data compared with the background predictions, which is most significant in the mass range between 120 and 135 GeV/c(2). The largest local significance is 3.3 standard deviations, corresponding to a global significance of 3.1 standard deviations. We interpret this as evidence for the presence of a new particle consistent with the standard model Higgs boson, which is produced in association with a weak vector boson and decays to a bottom-antibottom quark pair.
  •  
4.
  • Aaltonen, T., et al. (författare)
  • Combination of measurements of the top-quark pair production cross section from the Tevatron Collider
  • 2014
  • Ingår i: Physical Review D. - 1550-7998 .- 1550-2368. ; 89:7
  • Tidskriftsartikel (refereegranskat)abstract
    • We combine six measurements of the inclusive top-quark pair (t(sic)) production cross section (sigma(t)(sic)) from data collected with the CDF and D0 detectors at the Fermilab Tevatron with proton-antiproton collisions at root s = 1.96 TeV. The data correspond to integrated luminosities of up to 8.8 fb(-1). We obtain a value of sigma tt = 7.60 +/- 0.41 pb for a top-quark mass of m(t) = 172.5 GeV. The contributions to the uncertainty are 0.20 pb from statistical sources, 0.29 pb from systematic sources, and 0.21 pb from the uncertainty on the integrated luminosity. The result is in good agreement with the standard model expectation of 7.35(-0.33)(+0.28) pb at next-to-next-to-leading order and next-to-next-to leading logarithms in perturbative QCD.
  •  
5.
  • Aaltonen, T., et al. (författare)
  • Higgs boson studies at the Tevatron
  • 2013
  • Ingår i: Physical Review D. - 1550-7998 .- 1550-2368. ; 88:5, s. 052014-
  • Tidskriftsartikel (refereegranskat)abstract
    • We combine searches by the CDF and D0 Collaborations for the standard model Higgs boson with mass in the range 90-200 GeV/c(2) produced in the gluon-gluon fusion, WH, ZH, t (t) over barH, and vector boson fusion processes, and decaying in the H -> b (b) over bar, H -> W+W-, H -> ZZ, H -> tau(+)tau(-), and H -> gamma gamma modes. The data correspond to integrated luminosities of up to 10 fb(-1) and were collected at the Fermilab Tevatron in p (p) over bar collisions at root s = 1.96 TeV. The searches are also interpreted in the context of fermiophobic and fourth generation models. We observe a significant excess of events in the mass range between 115 and 140 GeV/c(2). The local significance corresponds to 3.0 standard deviations at m(H) = 125 GeV/c(2), consistent with the mass of the Higgs boson observed at the LHC, and we expect a local significance of 1.9 standard deviations. We separately combine searches for H -> b (b) over bar, H -> W+W-, H -> tau(+)tau(-), and H -> gamma gamma. The observed signal strengths in all channels are consistent with the presence of a standard model Higgs boson with a mass of 125 GeV/c(2).
  •  
6.
  • Aaltonen, T., et al. (författare)
  • Observation of s-Channel Production of Single Top Quarks at the Tevatron
  • 2014
  • Ingår i: Physical Review Letters. - 0031-9007 .- 1079-7114. ; 112:23
  • Tidskriftsartikel (refereegranskat)abstract
    • We report the first observation of single-top-quark production in the s channel through the combination of the CDF and D0 measurements of the cross section in proton-antiproton collisions at a center-of-mass energy of 1.96 TeV. The data correspond to total integrated luminosities of up to 9.7 fb(-1) per experiment. The measured cross section is sigma(s) = 1.29(-0.24)(+0.26) pb. The probability of observing a statistical fluctuation of the background to a cross section of the observed size or larger is 1.8 x 10(-10), corresponding to a significance of 6.3 standard deviations for the presence of an s-channel contribution to the production of single-top quarks.
  •  
7.
  • Aaltonen, T., et al. (författare)
  • Combination of CDF and D0 W-Boson mass measurements
  • 2013
  • Ingår i: Physical Review D. - 1550-7998 .- 1550-2368. ; 88:5, s. 052018-
  • Tidskriftsartikel (refereegranskat)abstract
    • We summarize and combine direct measurements of the mass of the W boson in root s = 1.96 TeV proton-antiproton collision data collected by CDF and D0 experiments at the Fermilab Tevatron Collider. Earlier measurements from CDF and D0 are combined with the two latest, more precise measurements: a CDF measurement in the electron and muon channels using data corresponding to 2.2 fb(-1) of integrated luminosity, and a D0 measurement in the electron channel using data corresponding to 4.3 fb(-1) of integrated luminosity. The resulting Tevatron average for the mass of the W boson is M-W = 80387 +/- 16 MeV. Including measurements obtained in electron-positron collisions at LEP yields the most precise value of M-W = 80385 +/- 15 MeV.
  •  
8.
  • Reed, R. A., et al. (författare)
  • Anthology of the Development of Radiation Transport Tools as Applied to Single Event Effects
  • 2013
  • Ingår i: IEEE Transactions on Nuclear Science. - : Institute of Electrical and Electronics Engineers (IEEE). - 0018-9499 .- 1558-1578. ; 60:3, s. 1876-1911
  • Tidskriftsartikel (refereegranskat)abstract
    • This anthology contains contributions from eleven different groups, each developing and/or applying Monte Carlo-based radiation transport tools to simulate a variety of effects that result from energy transferred to a semiconductor material by a single particle event. The topics span from basic mechanisms for single-particle induced failures to applied tasks like developing websites to predict on-orbit single event failure rates using Monte Carlo radiation transport tools.
  •  
9.
  • Petri, Michelle, et al. (författare)
  • Derivation and validation of the systemic lupus international collaborating clinics classification criteria for systemic lupus erythematosus
  • 2012
  • Ingår i: Arthritis and Rheumatism. - : Wiley. - 1529-0131 .- 0004-3591. ; 64:8, s. 2677-2686
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective The Systemic Lupus International Collaborating Clinics (SLICC) group revised and validated the American College of Rheumatology (ACR) systemic lupus erythematosus (SLE) classification criteria in order to improve clinical relevance, meet stringent methodology requirements, and incorporate new knowledge regarding the immunology of SLE. Methods The classification criteria were derived from a set of 702 expert-rated patient scenarios. Recursive partitioning was used to derive an initial rule that was simplified and refined based on SLICC physician consensus. The SLICC group validated the classification criteria in a new validation sample of 690 new expert-rated patient scenarios. Results Seventeen criteria were identified. In the derivation set, the SLICC classification criteria resulted in fewer misclassifications compared with the current ACR classification criteria (49 versus 70; P = 0.0082) and had greater sensitivity (94% versus 86%; P < 0.0001) and equal specificity (92% versus 93%; P = 0.39). In the validation set, the SLICC classification criteria resulted in fewer misclassifications compared with the current ACR classification criteria (62 versus 74; P = 0.24) and had greater sensitivity (97% versus 83%; P < 0.0001) but lower specificity (84% versus 96%; P < 0.0001). Conclusion The new SLICC classification criteria performed well in a large set of patient scenarios rated by experts. According to the SLICC rule for the classification of SLE, the patient must satisfy at least 4 criteria, including at least one clinical criterion and one immunologic criterion OR the patient must have biopsy-proven lupus nephritis in the presence of antinuclear antibodies or antidouble-stranded DNA antibodies.
  •  
10.
  • Brownstein, Catherine A., et al. (författare)
  • An international effort towards developing standards for best practices in analysis, interpretation and reporting of clinical genome sequencing results in the CLARITY Challenge
  • 2014
  • Ingår i: Genome Biology. - : Springer Science and Business Media LLC. - 1465-6906 .- 1474-760X. ; 15:3, s. R53-
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: There is tremendous potential for genome sequencing to improve clinical diagnosis and care once it becomes routinely accessible, but this will require formalizing research methods into clinical best practices in the areas of sequence data generation, analysis, interpretation and reporting. The CLARITY Challenge was designed to spur convergence in methods for diagnosing genetic disease starting from clinical case history and genome sequencing data. DNA samples were obtained from three families with heritable genetic disorders and genomic sequence data were donated by sequencing platform vendors. The challenge was to analyze and interpret these data with the goals of identifying disease-causing variants and reporting the findings in a clinically useful format. Participating contestant groups were solicited broadly, and an independent panel of judges evaluated their performance. Results: A total of 30 international groups were engaged. The entries reveal a general convergence of practices on most elements of the analysis and interpretation process. However, even given this commonality of approach, only two groups identified the consensus candidate variants in all disease cases, demonstrating a need for consistent fine-tuning of the generally accepted methods. There was greater diversity of the final clinical report content and in the patient consenting process, demonstrating that these areas require additional exploration and standardization. Conclusions: The CLARITY Challenge provides a comprehensive assessment of current practices for using genome sequencing to diagnose and report genetic diseases. There is remarkable convergence in bioinformatic techniques, but medical interpretation and reporting are areas that require further development by many groups.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 13

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy