SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Muto M) srt2:(2015-2019)"

Sökning: WFRF:(Muto M) > (2015-2019)

  • Resultat 1-8 av 8
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Grady, C., et al. (författare)
  • The outer disks of Herbig stars from the UV to NIR
  • 2015
  • Ingår i: Astrophysics and Space Science. - : Springer Science and Business Media LLC. - 0004-640X .- 1572-946X. ; 355:2, s. 253-266
  • Forskningsöversikt (refereegranskat)abstract
    • Spatially-resolved imaging of Herbig stars and related objects began with HST, but intensified with commissioning of high-contrast imagers on 8-m class telescopes. The bulk of the data taken from the ground have been polarized intensity imagery at H-band, with the majority of the sources observed as part of the Strategic Exploration of Exoplanets and Disks with Subaru (SEEDS) survey. Sufficiently many systems have been imaged that we discuss disk properties in scattered, polarized light in terms of groups defined by the IR spectral energy distribution. We find novel phenomena in many of the disks, including spiral density waves, and discuss the disks in terms of clearing mechanisms. Some of the disks have sufficient data to map the dust and gas components, including water ice dissociation products.
  •  
2.
  • Akiyama, E., et al. (författare)
  • DISCOVERY OF A DISK GAP CANDIDATE AT 20 AU IN TW HYDRAE
  • 2015
  • Ingår i: Astrophysical Journal Letters. - 2041-8205 .- 2041-8213. ; 802:2
  • Tidskriftsartikel (refereegranskat)abstract
    • We present a new Subaru/HiCIAO high-contrast H-band polarized intensity (PI) image of a nearby transitional disk associated with TW Hydrae. The scattered light from the disk was detected from 0 ''.2 to 1 ''.5 (11-81 AU) and the PI image shows a clear axisymmetric depression in PI at similar to 0 ''.4 (similar to 20 AU) from the central star, similar to the similar to 80 AU gap previously reported from Hubble Space Telescope images. The azimuthal PI profile also shows that the disk beyond 0 ''.2 is almost axisymmetric. We discuss two possible scenarios explaining the origin of the PI depression: (1) a gap structure may exist at similar to 20 AU from the central star because of a shallow slope seen in the PI profile, and (2) grain growth may be occurring in the inner region of the disk. Multi-band observations at near-infrared and millimeter/submillimeter wavelengths play a complementary role in investigating dust opacity and may help reveal the origin of the gap more precisely.
  •  
3.
  •  
4.
  •  
5.
  • Rusz, Ján, et al. (författare)
  • Magnetic measurements with atomic-plane resolution
  • 2016
  • Ingår i: Nature Communications. - : Springer Science and Business Media LLC. - 2041-1723. ; 7
  • Tidskriftsartikel (refereegranskat)abstract
    • Rapid development of magnetic nanotechnologies calls for experimental techniques capable of providing magnetic information with subnanometre spatial resolution. Available probes of magnetism either detect only surface properties, such as spin-polarized scanning tunnelling microscopy, magnetic force microscopy or spin-polarized low-energy electron microscopy, or they are bulk probes with limited spatial resolution or quantitativeness, such as X-ray magnetic circular dichroism or classical electron magnetic circular dichroism (EMCD). Atomic resolution EMCD methods have been proposed, although not yet experimentally realized. Here, we demonstrate an EMCD technique with an atomic size electron probe utilizing a probe-corrected scanning transmission electron microscope in its standard operation mode. The crucial element of the method is a ramp in the phase of the electron beam wavefunction, introduced by a controlled beam displacement. We detect EMCD signals with atomic-plane resolution, thereby bringing near-atomic resolution magnetic circular dichroism spectroscopy to hundreds of laboratories worldwide.
  •  
6.
  • Follette, Katherine B., et al. (författare)
  • SEEDS ADAPTIVE OPTICS IMAGING OF THE ASYMMETRIC TRANSITION DISK OPH IRS 48 IN SCATTERED LIGHT
  • 2015
  • Ingår i: Astrophysical Journal. - 0004-637X .- 1538-4357. ; 798:2
  • Tidskriftsartikel (refereegranskat)abstract
    • We present the first resolved near-infrared imagery of the transition disk Oph IRS 48 (WLY 2-48), which was recently observed with ALMA to have a strongly asymmetric submillimeter flux distribution. H-band polarized intensity images show a similar to 60 AU radius scattered light cavity with two pronounced arcs of emission, one from northeast to southeast and one smaller, fainter, and more distant arc in the northwest. K-band scattered light imagery reveals a similar morphology, but with a clear third arc along the southwestern rim of the disk cavity. This arc meets the northwestern arc at nearly a right angle, revealing the presence of a spiral arm or local surface brightness deficit in the disk, and explaining the east-west brightness asymmetry in the H-band data. We also present 0.8-5.4 mu m IRTF SpeX spectra of this object, which allow us to constrain the spectral class to A0 +/- 1 and measure a low mass accretion rate of 10(-8.5) M-circle dot yr(-1), both consistent with previous estimates. We investigate a variety of reddening laws in order to fit the multiwavelength spectral energy distribution of Oph IRS 48 and find a best fit consistent with a younger, higher luminosity star than previous estimates.
  •  
7.
  • Rusz, Jan, 1979-, et al. (författare)
  • Localization of magnetic circular dichroic spectra in transmission electron microscopy experiments with atomic plane resolution
  • 2017
  • Ingår i: Physical Review B. - : AMER PHYSICAL SOC. - 2469-9950 .- 2469-9969. ; 95:17
  • Tidskriftsartikel (refereegranskat)abstract
    • Inelastic electron scattering is a consequence of mostly Coulomb interaction between electrons in the sample and electron beam and, as such, it is a nonlocal event. In atomic resolution experiments, it thus opens the following question: How far is the origin of the inelastic scattering signal that is observed when the electron beam is passing nearby an atomic column or plane? We analyze computationally the delocalization of the magnetic signal in electron magnetic circular dichroism (EMCD) experiments in the so-called three-beam orientation, allowing one to image individual atomic planes. We compare the classical EMCD setup using the double-difference procedure (DD-EMCD) to a recently introduced atomic plane resolution EMCD (APR-EMCD) geometry, assuming the same probe size. We observe a strong localization of the EMCD signal to the closest atomic plane, confirming the potential of EMCD to study an evolution of magnetic properties near surfaces or interfaces with atomic plane resolution. The localization of the EMCD signal is remarkably higher than the localization of the nonmagnetic component of the inelastic scattering cross section. We also analyze double-channeling effects and find them particularly strong for the DD-EMCD method, while for APR-EMCD they appear to be minor. The DD-EMCD signal, on the other hand, appears to be more robust with respect to sample thickness than that of the APR-EMCD.
  •  
8.
  • Thersleff, Thomas, et al. (författare)
  • Single-pass STEM-EMCD on a zone axis using a patterned aperture : progress in experimental and data treatment methods
  • 2019
  • Ingår i: Scientific Reports. - : Springer Science and Business Media LLC. - 2045-2322. ; 9
  • Tidskriftsartikel (refereegranskat)abstract
    • Measuring magnetic moments in ferromagnetic materials at atomic resolution is theoretically possible using the electron magnetic circular dichroism (EMCD) technique in a (scanning) transmission electron microscope ((S)TEM). However, experimental and data processing hurdles currently hamper the realization of this goal. Experimentally, the sample must be tilted to a zone-axis orientation, yielding a complex distribution of magnetic scattering intensity, and the same sample region must be scanned multiple times with sub-atomic spatial registration necessary at each pass. Furthermore, the weak nature of the EMCD signal requires advanced data processing techniques to reliably detect and quantify the result. In this manuscript, we detail our experimental and data processing progress towards achieving single-pass zone-axis EMCD using a patterned aperture. First, we provide a comprehensive data acquisition and analysis strategy for this and other EMCD experiments that should scale down to atomic resolution experiments. Second, we demonstrate that, at low spatial resolution, promising EMCD candidate signals can be extracted, and that these are sensitive to both crystallographic orientation and momentum transfer.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-8 av 8

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy