  • Bolmsjö, Magnus S., et al. (författare)
  • Imaging 123I with a scintillation camera. A study of detection performance and quality factor concepts
  • 1977
  • Ingår i: Physics in Medicine and Biology. - : IOP Publishing. - 0031-9155. ; 22:2, s. 266-277
  • Tidskriftsartikel (refereegranskat)abstract
    • Image quality, resolution and sensitivity of a scintillation camera equipped with various collimators have been investigated using high purity 123I. Pulse height distributions of 123I from a thyroid phantom partly in air and partly immersed in water demonstrated the substantial septa penetration of the 440 and 529 keV gamma rays of 123I with high resolution collimators. Line spread functions were recorded and the modulation transfer function was evaluated from them. The two concepts of 'figure of merit' also used were QB=Sa mod MTF mod 2, where Sa is the plane sensitivity and QC=S2/(S+2B), where S is the true signal from the object and B is the total background or noise due to septa penetration and scatter.
  •  
2.
  • Strand, Sven Erik, et al. (författare)
  • The dual photopeak-area method applied to scintillation camera measurements of effective depth and activity of in vivo 123I-distributions
  • 1977
  • Ingår i: European Journal Of Nuclear Medicine. - 0340-6997. ; 2:2, s. 121-128
  • Tidskriftsartikel (refereegranskat)abstract
    • Attenuation curves and photopeak ratios of 159 keV and 28 keV phtons emitted in the decay of 123I have been studied using a scintillation camera equipped with an extra ADC for recording the pulse height distribution of the energy signal. Cavities of various sizes containing 123I-solution were placed at different depths in a water phantom in order to vary the effective depth, i.e., the thickness of attenuating material above the cavity plus the distance to the centre of activity in the cavity. The centre of activity varies with the distribution of activity in the cavity, size of cavity, and the effective attenuation coefficient derived from the attenuation curves. From the photopeak ratio an average effective depth is determined which can be used for calculating the attenuation correction factor. The dual photopeak ratio has been used in clinical evaluation of thyroid 123I uptake measurements where effective depths ranging from 21 to 43 mm were obtained for the activity in the thyroid. Applications of the photopeak ratio method for renography with 123I-hippuran and blood flow studies using 133Xe or 127Xe and studies with many other radionuclides are also discussed.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2
Typ av publikation
tidskriftsartikel (2)
Typ av innehåll
refereegranskat (2)
Författare/redaktör
Strand, Sven-Erik (2)
Persson, Bertil R.R. (2)
Bolmsjö, Magnus S. (1)
Lärosäte
Lunds universitet (2)
Språk
Engelska (2)
År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy