SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Zucchelli S.) srt2:(2020-2024)"

Sökning: WFRF:(Zucchelli S.) > (2020-2024)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Jensen, Simon S., et al. (författare)
  • Group 1 ITI Consensus Report : The role of bone dimensions and soft tissue augmentation procedures on the stability of clinical, radiographic, and patient-reported outcomes of implant treatment
  • 2023
  • Ingår i: Clinical Oral Implants Research. - : John Wiley & Sons. - 0905-7161 .- 1600-0501. ; 34, s. 43-49
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: The aims of Working Group 1 were to address the role (i) of the buccolingual bone dimensions after implant placement in healed alveolar ridge sites on the occurrence of biologic and aesthetic complications, and (ii) of soft tissue augmentation (STA) on the stability of clinical, radiographic, and patient-related outcomes of implant treatments.Materials and Methods: Two systematic reviews were prepared in advance of the Consensus Conference and were discussed among the participants of Group 1. Consensus statements, clinical recommendations, recommendations for future research, and reflections on patient perspectives were based on structured group discussions until consensus was reached among the entire group of experts. The statements were then presented and accepted following further discussion and modifications as required by the plenary.Results: Dimensional changes of the alveolar ridge occurred after implant placement in healed sites, and a reduction in buccal bone wall thickness (BBW) of 0.3 to 1.8 mm was observed. In healed sites with a BBW of <1.5 mm after implant placement, increased vertical bone loss, and less favorable clinical and radiographic outcomes were demonstrated. Implants with buccal dehiscence defects undergoing simultaneous guided bone regeneration, showed less vertical bone loss, and more favorable clinical and radiographic outcomes, compared to non-augmented dehiscence defects during initial healing. At healthy single implant sites, probing depths, bleeding and plaque scores, and interproximal bone levels evaluated at 1 year, remained stable for up to 5 years, with or without STA. When single implant sites were augmented with connective tissue grafts, either for soft tissue phenotype modification or buccal soft tissue dehiscence, stable levels of the soft tissue margin, and stable or even increased soft tissue thickness and/or width of keratinized mucosa could be observed from 1 to 5 years. In contrast, non-augmented sites were more prone to show apical migration of the soft tissue margin in the long-term. Favorable aesthetic and patient-reported outcomes after STA were documented to be stable from 1 to 5 years.Results: Dimensional changes of the alveolar ridge occurred after implant placement in healed sites, and a reduction in buccal bone wall thickness (BBW) of 0.3 to 1.8 mm was observed. In healed sites with a BBW of <1.5 mm after implant placement, increased vertical bone loss, and less favorable clinical and radiographic outcomes were demonstrated. Implants with buccal dehiscence defects undergoing simultaneous guided bone regeneration, showed less vertical bone loss, and more favorable clinical and radiographic outcomes, compared to non-augmented dehiscence defects during initial healing. At healthy single implant sites, probing depths, bleeding and plaque scores, and interproximal bone levels evaluated at 1 year, remained stable for up to 5 years, with or without STA. When single implant sites were augmented with connective tissue grafts, either for soft tissue phenotype modification or buccal soft tissue dehiscence, stable levels of the soft tissue margin, and stable or even increased soft tissue thickness and/or width of keratinized mucosa could be observed from 1 to 5 years. In contrast, non-augmented sites were more prone to show apical migration of the soft tissue margin in the long-term. Favorable aesthetic and patient-reported outcomes after STA were documented to be stable from 1 to 5 years. Conclusions: It is concluded that dimensional changes of the alveolar ridge occur after implant placement in healed sites and that sites with a thin BBW after implant placement are prone to exhibit less favorable clinical and radiographic outcomes. In addition, it is concluded that STA can provide stable clinical, radiographic, aesthetic, and patient-reported outcomes in the medium and long-term.
  •  
3.
  •  
4.
  • Zucchelli, A, et al. (författare)
  • Technologies for the Instrumental Evaluation of Physical Function in Persons Affected by Chronic Obstructive Pulmonary Disease: A Systematic Review
  • 2022
  • Ingår i: Sensors (Basel, Switzerland). - : MDPI AG. - 1424-8220. ; 22:17
  • Tidskriftsartikel (refereegranskat)abstract
    • Several systems, sensors, and devices are now available for the instrumental evaluation of physical function in persons with Chronic Obstructive Pulmonary Disease (COPD). We aimed to systematically review the literature about such technologies. The literature search was conducted in all major scientific databases, including articles published between January 2001 and April 2022. Studies reporting measures derived from the instrumental assessment of physical function in individuals with COPD were included and were divided into application and validation studies. The quality of validation studies was assessed with the Consensus-based Standards for the selection of health Measurement Instruments (COSMIN) risk of bias tool. From 8752 articles retrieved, 21 application and 4 validation studies were included in the systematic review. Most application studies employed accelerometers, gait analysis systems, instrumented mattresses, or force plates to evaluate walking. Surface electro-myography or near-infrared spectroscopy were employed in four studies. Validation studies were heterogeneous and presented a risk of bias ranging from inadequate to doubtful. A variety of data regarding physical function can be retrieved from technologies used in COPD studies. However, a general lack of standardization and limitations in study design and sample size hinder the implementation of the instrumental evaluation of function in clinical practice.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy