SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0167 5273 "

Sökning: L773:0167 5273

  • Resultat 441-450 av 773
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
441.
  • Linker, N. J., et al. (författare)
  • Early versus delayed implantation of a loop recorder in patients with unexplained syncope - Effects on care pathway and diagnostic yield
  • 2013
  • Ingår i: International Journal of Cardiology. - : Elsevier BV. - 0167-5273. ; 170:2, s. 146-151
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: This study looked to assess the care pathway and diagnostic yield in patients who received an implantable loop recorder (ILR) after an "initial phase of the diagnostic work-up" (initial work-up) or after a "full evaluation" of unexplained syncope. Methods and results: Physicians classified the timing of an ILR implant in 514 patients as either following an "initial work-up" (n = 128; 25%) or "full evaluation" (n = 386; 75%). Patients with an "initial work-up" underwent a median (IQ range) of 8 (6-14) tests prior to ILR implant compared to 14 (10-21) tests after "full evaluation" (p<0.0001). Hospitalization and injury before implant were less common in patients with an "initial work-up": 53 vs. 75%, p<0001, and 23% vs. 39%, p<0.001, as were visits to specialists, e. g. neurologist, 32% vs. 50%, p<0.001. At one year after implant, the syncope recurrence rate was 32% in the initial work-up group and 36% in the full evaluation group, and the incidence of recurrences with an ILR-guided diagnosis was 52% and 75% respectively. Diagnoses were cardiac in 90% after "initial work-up" vs. 79% after "full evaluation". Conclusions: Patients who only underwent an "initial work-up" had fewer investigations and a lower incidence of injury or hospitalization. The diagnostic yield from the ILR was high in both groups. Patients in both groups underwent more investigations than suggested in the ESC guidelines and could have benefitted from limiting the initial evaluation before an ILR is implanted. (c) 2013 Elsevier Ireland Ltd. All rights reserved.
  •  
442.
  • Lipton, J. A., et al. (författare)
  • High frequency QRS electrocardiogram analysis during exercise stress testing for detecting ischemia
  • 2008
  • Ingår i: International Journal of Cardiology. - : Elsevier BV. - 0167-5273. ; 124:2, s. 198-203
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction ECG stress testing is an inexpensive and non-invasive detector of myocardial ischemia; addition of high-frequency QRS analysis (HFQRS) may improve accuracy. This study compared HFQRS during exercise in patients with and without ischemia as defined by multiple criteria. Material and methods High-resolution ECGs were recorded for 139 patients undergoing T99-sestamibi/T201-thallium stress testing. Twenty-three were positive by at least two and 37 were negative for ischemia by all three of the following criteria: nuclear scan, ST-segment analysis and typical angina. Sixty-four not meeting criteria for positive or negative, six with adenosine test and nine patients with ECG recording artifacts were excluded. Mean age of the study group was 62 ± 10 years, 83% were male. Ischemic patients had a higher incidence of previous myocardial infarction and coronary intervention than non-ischemic patients (74% vs. 46%; P = 0.03 and 70% vs. 43%; P = 0.05, respectively), but had a lower body mass index (28.7 ± 5 vs. 33.0 ± 8; P = 0.015). HFQRS analysis consisting of signal averaging (150–250 Hz) and calculation of root mean squared values for each lead at different time points was performed and was similar between the groups. The relative change in HFQRS (RCQ) was calculated for each lead: {(maxHFQRS − minHFQRS) / maxHFQRS}. For each patient an RCQ index was calculated by averaging the two leads with the greatest RCQ value. The RCQ index was greater in ischemic vs. non-ischemic patients (45% vs. 34%; P = 0.0069). Conclusion Maximum decrease in HFQRS, as quantified by RCQ index, was greater in ischemic vs. non-ischemic patients. Use of the RCQ index may improve the diagnosis of ischemia during exercise stress testing.
  •  
443.
  • Lisi, Matteo, et al. (författare)
  • Mitral annular longitudinal function preservation after mitral valve repair : the MARTE study
  • 2012
  • Ingår i: International Journal of Cardiology. - : Elsevier. - 0167-5273 .- 1874-1754. ; 157:2, s. 212-215
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: In patients with chronic mitral regurgitation (MR), undergoing surgical mitral valve repair, current Guidelines only recommend standard echocardiographic indices i.e. left ventricular (LV) ejection fraction (EF), and LV end-systolic and end-diastolic diameters as preoperative variables. However LV EF is often preserved until advanced stages of the valve disease. Aim of this study was to evaluate changes in LV systolic longitudinal function, 3months after mitral valve repair in patients with chronic degenerative MR and normal preoperative EF.METHODS: We measured M-mode mitral lateral annulus systolic excursion (MAPSE) and Tissue Doppler (TD) peak systolic annular velocity (S(m)) in 31 patients with moderate to severe MR and normal EF (59.9±4.7%) candidates for mitral valve repair, preoperatively and 3months after surgery.RESULTS: After mitral valve repair, S(m) increased from 7.8±1.4 to 9.6±2.2cm/s (p<0.0001) and MAPSE increased from 1.33±0.26 to 1.55±0.25cm (p=0.0013). EF decreased from 59.9±4.7 to 51.3±5.9% (p<0.0001). As expected, LV diameters and volumes, wall thicknesses, midwall fractional shortening (mFS), and left atrial (LA) size were all reduced after surgery.CONCLUSIONS: This study suggests that assessment of LV long axis systolic velocity and amplitude of excursion by echocardiography is more sensitive than simple determination of EF for revealing the beneficial impact of MR surgery on overall systolic function.
  •  
444.
  • Lisi, Matteo, 1982-, et al. (författare)
  • Severity of aortic stenosis predicts early post-operative normalization of left atrial size and function detected by myocardial strain
  • 2013
  • Ingår i: International Journal of Cardiology. - : Elsevier BV. - 0167-5273 .- 1874-1754. ; 167:4, s. 1450-1455
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Aortic stenosis (AS) causes significant disturbances in left ventricular (LV) and left atrial (LA) function irrespective of the extent of myocardial hypertrophy which associates the increased afterload. We hypothesize that aortic valve replacement (AVR) and removal of LV outflow tract obstruction should result in LA size and function recovery, even partial, and were set to study this in a group of patients with AVR for AS.METHODS: Peak atrial longitudinal strain (PALS) was evaluated in 43 patients with severe isolated AS and normal EF (56.6±3.8%) and no obstructive coronary artery disease candidates for AVR, pre-operatively and then 40days and 3months after surgery. Results were compared with those from 34 age- and gender-matched healthy controls.RESULTS: LVEF remained unchanged and LV mass regressed after AVR. Global PALS was reduced pre-operatively and increased 40days after surgery (p=0.002) and showed only a slight further increase at 3months follow-up (p<0.0001). Indexed LA volume was increased before surgery, but significantly fell 40days after surgery (p<0.0001) and showed only a slight further reduction after 3months (p<0.0001). Trans-aortic mean gradient change after surgery was the only independent predictor of the recovery of LA size and function.CONCLUSIONS: AVR reverses LA abnormalities and regains normal atrial function, a behavior which is directly related to the severity of pre-operative LV outflow tract obstruction. Early identification of LA size enlargement and functional disturbances might contribute to better patient's recruitment for AVR.
  •  
445.
  • Ljung Faxen, Ulrika, et al. (författare)
  • HFpEF and HFrEF exhibit different phenotypes as assessed by leptin and adiponectin
  • 2017
  • Ingår i: International Journal of Cardiology. - : Elsevier BV. - 0167-5273 .- 1874-1754. ; 228, s. 709-716
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Heart failure with reduced ejection fraction (HFrEF) exhibits a reverse metabolic profile. Whether this profile exists in HF with preserved ejection fraction (HFpEF) is unknown. We tested the hypothesis that HFpEF and HFrEF are similar regarding concentrations of and prognostic impact of leptin and adiponectin.Methods: In patients with HFpEF(n = 79), HFrEF(n = 84), and controls(n = 71), we analyzed serum leptin and adiponectin concentrations, their correlations, and associations with outcome.Results: Leptin levels in HFpEF and HFrEF were increased (p < 0.05) compared to controls; with the highest levels in HFpEF, median (IQR), 23.1 (10.2-51.0), vs. HFrEF 15.0 (6.2-33.2), and vs. controls 10.8 (5.4-18.9) ng/mL. There was no difference between HFpEF and HFrEF p=0.125 (adjusted for gender, BMI and age). Leptin was inversely associated with NT-proBNP (r = -0.364 p = 0.001) and associated with better outcome in HFrEF (HR per ln increase of leptin 0.76, 95% CI 0.58-0.99, p = 0.044) but not in HFpEF.Crude levels of adiponectin were similar in HFpEF: 11.8 (7.9-20.1), HFrEF: 13.7 (7.0-21.1), and controls: 10.5 (7.4-15.1) mu g/L. In men, adjusted similarly as leptin, there was no difference between HFpEF and HFrEF, p = 0.310 but, compared to controls, higher levels in HFpEF (p - 0.044) and HFrEF (p - 0.001). Adiponectin correlated positively with NT-proBNP; r = 0.396 p < 0.001 and higher levels were associated with adverse outcome only in HFrEF (HR per ln increase 2.88 (95% CI 1.02-8.14, p = 0.045).Conclusion: HFpEF and HFrEF share elevated levels of leptin and adiponectin. However, the concept of reverse metabolic profile could not be confirmed in HFpEF, suggesting that HFpEF might have a conventional metabolic profile, rather than a distinct HF syndrome.
  •  
446.
  • Ljung Faxen, Ulrika, et al. (författare)
  • N-terminal pro-B-type natriuretic peptide in chronic heart failure: The impact of sex across the ejection fraction spectrum
  • 2019
  • Ingår i: International Journal of Cardiology. - : ELSEVIER IRELAND LTD. - 0167-5273 .- 1874-1754. ; 21, s. 225-225
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: The aim was to assess sex-specific differences in N-terminal B-type natriuretic peptide (NT-proBNP) regarding concentrations, predictors of high concentrations, and prognostic role, in a large and unselected population with chronic heart failure (HF) with preserved (HFpEF), mid-range (HFmrEF), and reduced ejection fraction (HFrEF). Methods and results: In 9847 outpatients with HFpEF, HFmrEF, and HFrEF (49 vs. 35 vs. 25% females, respectively) from the Swedish HF Registry, median NT-proBNP concentrations were 1598 ng/L in females vs. 1310 ng/L in males in HFpEF, 1764 vs. 1464 ng/L in HFmrEF, and 2543 vs. 2226 ng/L in HFrEF (p amp;lt; 0.05 for all). The differences persisted after multiple adjustment. The largest sex-difference in NT-proBNP levels was observed in HFpEF with sinus rhythm, where median concentrations were 1.4 folds higher in females (923 vs. 647 ng/L). Independent predictors of NT-proBNP levels (defined as above the different medians according to sex and HF phenotype) were overall consistent across sexes and EF. NT-proBNP levels were similarly associated with risk of all-cause death/HF hospitalization in both sexes regardless of EF. Conclusion: Concentrations of NT-proBNPwere higher in females across the EF spectrum, with larger relative differences in HFpEF with sinus rhythm. However, similar predictors of high levels were observed in both sexes. There were no sex-differences in the prognostic role of NT-proBNP. These findings support the use of NT-proBNP for prognostic purposes in chronic HF, regardless of sex. (c) 2019 Elsevier B.V. All rights reserved.
  •  
447.
  • Ljung, Lina, et al. (författare)
  • Sensitivity of undetectable level of high-sensitivity troponin T at presentation in a large non-ST-segment elevation myocardial infarction cohort of early presenters
  • 2019
  • Ingår i: International Journal of Cardiology. - : Elsevier BV. - 0167-5273 .- 1874-1754. ; 284, s. 6-11
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: We aimed to evaluate the diagnostic sensitivity for myocardial infarction (MI) when using an undetectable level of high-sensitivity cardiac troponin T (hs-cTnT < 5 ng/L) at presentation combined with a non-ischemic electrocardiogram (ECG), to rule out MI in a non-ST-segment elevation MI (NSTEMI) cohort presenting ≤2 h from symptom onset. We also aimed to compare baseline characteristics and 30-day outcome in NSTEMI patients presenting with and without hs-cTnT < 5 ng/L.METHODS: All patients admitted to five centers in Sweden 2011-2015, after the introduction of hs-cTnT, who presented ≤2 h from symptom onset and received a final diagnosis of NSTEMI, were identified through the SWEDEHEART registry. These data and data of hs-cTnT levels were verified in the hospitals' medical records. The registry provided baseline and outcome data.RESULTS: Twenty-four (2.6%) of 911 NSTEMI patients presented with hs-cTnT < 5 ng/L. In patients presenting >1-≤2 h from symptom onset the sensitivity for MI when combining hs-cTnT and ECG was 99.4% (95% CI 98.4%-99.8%). In patients presenting ≤1 h, and in patients aged ≤65 years without prior MI, the sensitivity was insufficient. NSTEMI patients presenting with hs-cTnT < 5 ng/L were younger and had less often a prior MI. A total of 62.5 vs. 63.5% of the NSTEMI patients presenting with and without hs-cTnT < 5 ng/L underwent revascularization within 30 days and 4.5 and 3.2% died respectively.CONCLUSIONS: Hs-cTnT < 5 ng/L at presentation combined with a non-ischemic ECG may be used to rule out MI in patients presenting as early as >1 h from symptom onset with a sufficient sensitivity.
  •  
448.
  •  
449.
  •  
450.
  • Lund, LH, et al. (författare)
  • Iron deficiency in heart failure
  • 2020
  • Ingår i: International journal of cardiology. - : Elsevier BV. - 1874-1754 .- 0167-5273. ; 299, s. 207-207
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 441-450 av 773
Typ av publikation
tidskriftsartikel (747)
forskningsöversikt (24)
annan publikation (1)
konferensbidrag (1)
Typ av innehåll
refereegranskat (683)
övrigt vetenskapligt/konstnärligt (90)
Författare/redaktör
Henein, Michael Y. (59)
Herlitz, Johan, 1949 (36)
Karlsson, Thomas, 19 ... (34)
Herlitz, Johan (32)
Omerovic, Elmir, 196 ... (26)
Dellborg, Mikael, 19 ... (25)
visa fler...
Fu, Michael, 1963 (25)
Moons, Philip, 1968 (22)
Y-Hassan, S (22)
Redfors, Björn (20)
Agewall, S (19)
Johansson, Bengt (19)
Henein, Michael (19)
Lindqvist, Per (18)
Dahlström, Ulf (18)
Caidahl, Kenneth, 19 ... (17)
Hartford, Marianne, ... (16)
Holzmann, MJ (15)
Savarese, G (14)
Lund, LH (14)
Thilén, Ulf (14)
Lund, Lars H. (13)
Rosengren, Annika, 1 ... (13)
Sundquist, Kristina (12)
Jernberg, Tomas (12)
Budts, Werner (12)
Nicoll, Rachel (12)
Shao, Yangzhen, 1981 (12)
Linde, C (11)
Sartipy, U (11)
Mörner, Stellan (11)
Swedberg, Karl, 1944 (10)
Sundquist, Jan (10)
Carlsson, Axel C. (10)
Willenheimer, Ronnie (10)
Eriksson, Peter J, 1 ... (10)
Karlson, Björn W., 1 ... (9)
Bajraktari, Gani (9)
Janszky, I (9)
Karlson, BW (9)
Alehagen, Urban (8)
Wolk, Alicja (8)
Karlsson, T (8)
Erlinge, David (8)
Li, Wei (8)
Lindahl, Bertil (8)
Christersson, Christ ... (8)
Bång, Angela (8)
Zhao, Ying (8)
Hjalmarson, Å (8)
visa färre...
Lärosäte
Karolinska Institutet (322)
Göteborgs universitet (215)
Lunds universitet (124)
Umeå universitet (119)
Uppsala universitet (116)
Linköpings universitet (67)
visa fler...
Högskolan i Borås (63)
Örebro universitet (24)
Stockholms universitet (10)
Högskolan Väst (9)
Högskolan i Skövde (7)
Chalmers tekniska högskola (7)
Kungliga Tekniska Högskolan (6)
Linnéuniversitetet (5)
Högskolan Dalarna (3)
Jönköping University (2)
Högskolan i Gävle (1)
Mälardalens universitet (1)
Mittuniversitetet (1)
visa färre...
Språk
Engelska (773)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (507)
Samhällsvetenskap (9)
Naturvetenskap (4)
Teknik (3)
Humaniora (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy