41.
  • Hansson, Jonny, et al. (författare)
  • An optimisation strategy in a digital environment applied to neonatal chest imaging.
  • 2005
  • Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 114:1-3, s. 278-85
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of this study was to find the optimum tube voltage for neonatal chest imaging in computed radiography. The study was designed to take full advantage of the benefits of digital imaging, for example, by comparing the tube voltages at constant effective dose. A phantom study using a living rabbit was first conducted. Images were collected at tube voltages ranging from 40 to 90 kV(p). The reproduction of four structures (central vessels, peripheral vessels, carina and thoracic vertebrae) was rated by 10 radiologists. The reproduction of both central and peripheral vessels was relatively independent of tube voltage. The carina was better reproduced at higher tube voltages whereas the opposite was true for the thoracic vertebrae. Based on the higher importance of the reproduction of the carina it was decided that 90 kV(p) was the optimal tube voltage. To validate the result from the phantom study, a follow-up study was conducted in which images of neonates collected at the tube voltage regularly used at Sahlgrenska University Hospital (70 kV(p)) were compared with images collected at the tube voltage proposed by the phantom study. The follow-up study confirmed the results from the phantom study that the reproduction of the carina was better at 90 than at 70 kV(p). In conclusion, for neonatal chest imaging-given the same effective dose-90 kVp gives better reproduction of important structures than the regularly used 70 kV(p).
  •  
42.
  • Hansson, Jonny, et al. (författare)
  • Comparison of three methods for determining CT dose profile: presenting the tritium method
  • 2010
  • Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 1742-3406 .- 0144-8420. ; 139:1-3, s. 434-438
  • Tidskriftsartikel (refereegranskat)abstract
    • The purpose of the present work was to describe a method of using an imaging plate from a computed radiography system to determine the computed tomography (CT) dose profile (the tritium method) and to compare this method with point-dose measurements using a solid-state detector (CT Dose Profiler; RTI Electronics, Mölndal, Sweden) and the indirect method of comparing the air kerma-length product (P(KL)) at different beam collimations. The three methods were used to determine the full width at half maximum (FWHM) of the dose profile of a multi-slice CT at different nominal beam collimations. For all beam collimations, the obtained deviation between the tritium method and the CT Dose Profiler was smaller than 0.1 mm. The maximum relative error was 2 %. For the P(KL) method, the deviation from the CT Dose Profiler was between 0.2 and 0.4 mm, resulting in a relative error larger than 10 % for the smallest beam collimation even after normalisation to a known FWHM. In conclusion, the proposed method of using an imaging plate to determine the FWHM of the CT dose profile has a high accuracy and shows good agreement with the more advanced method of point-dose measurements using a solid-state detector.
  •  
43.
  • Hansson, Jonny, et al. (författare)
  • EVALUATION OF VGC ANALYZER BY COMPARISON WITH GOLD STANDARD ROC SOFTWARE AND ANALYSIS OF SIMULATED VISUAL GRADING DATA
  • 2021
  • Ingår i: Radiation Protection Dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 195:3-4, s. 378-390
  • Tidskriftsartikel (refereegranskat)abstract
    • The purpose of the present work was to evaluate the use of resampling statistical methods for analysis of visual grading data-implemented in the software VGC Analyzer-by comparing the reanalyzed results from previously performed visual grading studies with the results calculated by gold standard receiver operating characteristic (ROC) methodology, Obuchowski-Rockette (OR)-Dorfman-Berbaum-Metz (DBM) multiple-readers and multiple-case (MRMC) and by analysis of simulated visual grading data where the true distribution was presumed to be known. The reanalysis was performed on two multiple-reader studies with non-paired data and paired data, respectively. The simulation study was performed by simulating a large number of visual grading characteristics (VGC) studies and by analyzing the statistical distribution of null hypothesis (H-0) rejection rate. The comparison with OR-DBM MRMC showed good agreement when analyzing non-paired data for both fixed-reader and random-reader settings for the calculated area under the curve values and the confidence intervals (CIs). For paired data analysis, VGC Analyzer showed significantly lower CIs compared with the ROC software. This effect was also illustrated by the simulation study, where the VGC Analyzer, in general, showed good accuracy for simulated studies with stable statistical basis. For simulated studies with unstable statistics, the accuracy in the H-0 rejection rate decreased. The present study has shown that resampling methodology can be used to accurately perform the statistical analysis of a VGC study, although the resampling technique used makes the method sensitive to small data sets.
  •  
44.
  • Hansson, Jonny, et al. (författare)
  • THE VALIDITY OF USING ROC SOFTWARE FOR ANALYSING VISUAL GRADING CHARACTERISTICS DATA: AN INVESTIGATION BASED ON THE NOVEL SOFTWARE VGC ANALYZER
  • 2016
  • Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 1742-3406 .- 0144-8420. ; 169:1-4, s. 54-59
  • Tidskriftsartikel (refereegranskat)abstract
    • The purpose of the present work was to investigate the validity of using single-reader-adapted receiver operating characteristics (ROC) software for analysis of visual grading characteristics (VGC) data. VGC data from four published VGC studies on optimisation of X-ray examinations, previously analysed using ROCFIT, were reanalysed using a recently developed software dedicated to VGC analysis (VGC Analyzer), and the outcomes [the mean and 95 % confidence interval (CI) of the area under the VGC curve (AUCVGC) and the p-value] were compared. The studies included both paired and non-paired data and were reanalysed both for the fixed-reader and the random-reader situations. The results showed good agreement between the softwares for the mean AUCVGC. For non-paired data, wider CIs were obtained with VGC Analyzer than previously reported, whereas for paired data, the previously reported CIs were similar or even broader. Similar observations were made for the p-values. The results indicate that the use of single-reader-adapted ROC software such as ROCFIT for analysing non-paired VGC data may lead to an increased risk of committing Type I errors, especially in the random-reader situation. On the other hand, the use of ROC software for analysis of paired VGC data may lead to an increased risk of committing Type II errors, especially in the fixed-reader situation.
  •  
45.
  • Hemdal, Bengt, et al. (författare)
  • Can the average glandular dose in routine digital mammography screening be reduced? A pilot study using revised image quality criteria.
  • 2005
  • Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 114:1-3, s. 383-8
  • Tidskriftsartikel (refereegranskat)abstract
    • There is a need for tools that in a simple way can be used for the evaluation of image quality related to clinical requirements in mammography. The aim of this work was to adjust the present European image quality criteria to be relevant also for digital mammography images, and to use as simple and as few criteria as possible. A pilot evaluation of the new set of criteria was made with mammograms of 28 women from a General Electric Senographe 2000D full-field digital mammography system. One breast was exposed using the standard automatic exposure mode, the other using about half of that absorbed dose. Three experienced radiologists evaluated the images using visual grading analysis technique. The results indicate that the new quality criteria can be used for the evaluation of image quality related to clinical requirements in digital mammography in a simple way. The results also suggest that absorbed doses for the mammography system used may be substantially reduced.
  •  
46.
  • Hemdal, Bengt, et al. (författare)
  • Clinical evaluation of a new set of image quality criteria for mammography.
  • 2005
  • Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 114:1-3, s. 389-94
  • Tidskriftsartikel (refereegranskat)abstract
    • The European Commission (EC) quality criteria for screen-film mammography are used as a tool to assess image quality. A new set of criteria was developed and initially tested in a previous study. In the present study, these criteria are further evaluated using screen-film mammograms that have been digitised, manipulated to simulate different image quality levels and reprinted on film. Expert radiologists have evaluated these manipulated images using both the original (EC) and the new criteria. A comparison of three different simulated dose levels reveals that the new criteria yield a larger separation of image criteria scores than the old ones. These results indicate that the new set of image quality criteria has a higher discriminative power than the old set and thus seems to be more suitable for evaluation of image quality in mammography.
  •  
47.
  • Håkansson, Markus, et al. (författare)
  • Nodule detection in digital chest radiography: effect of nodule location.
  • 2005
  • Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 114:1-3, s. 92-6
  • Tidskriftsartikel (refereegranskat)abstract
    • Most detection studies in chest radiography treat the entire chest image as a single background or divided into the two regions parenchyma and mediastinum. However, the different parts of the lung show great variations in attenuation and structure, leading to different amounts of quantum noise and scattered radiation as well as different complexity. Detailed data on the difference in detectability in the different regions are of importance. The purpose of this study was to quantify the difference in detectability between different regions of a chest image. The chest X ray was divided into six different regions, where each region was considered to be uniform in terms of detectability. Thirty clinical chest images were collected and divided into the different regions. Simulated designer nodules with a full-width-at-fifth-maximum of 10 mm but with varying contrast were added to the images. An equal number of images lacking pathology were included and a receiver operating characteristic (ROC) study was conducted with five observers. Results show that the image contrast needed to obtain a constant value of A(z) (area under an ROC curve) differs by more than a factor of four between different regions.
  •  
48.
  • Håkansson, Markus, et al. (författare)
  • Nodule detection in digital chest radiography: effect of system noise.
  • 2005
  • Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 114:1-3, s. 97-101
  • Tidskriftsartikel (refereegranskat)abstract
    • Apart from the image content that is the reproduction of anatomy and possible lesions, an X-ray image also contains system noise due to the limited number of photons and other internal noise sources in the system (image plate artefacts, electronic noise, etc.). The aim of this study was to determine the extent to which the system noise influences the detection of subtle lung nodules in five different regions of the chest. This was done by conducting a receiver operating characteristic (ROC) study with five observers on two different sets of images; clinical chest X-ray images and images of a LucAl phantom at similar dose levels found in the different regions of the chest. In both image types, mathematically simulated nodules (with a full-width-at-fifth-maximum of 10 mm) were added to the images at varying contrast levels. As a measure of the influence of system noise on the detection of subtle lung nodules, the ratio between the contrast needed to obtain an area under the ROC curve of 0.80 in the system noise images to that needed in the clinical images was used. The contrast ratio between system noise images and clinical images ranged from approximately 0.02 (in the hilar region) to 0.18 (in the lower mediastinal region). The maximum difference in contrast needed for the corresponding system noise images, collected at the lowest and the highest dose represented in the anatomical image, was a factor of 2. These results indicate that probably no region in a chest X-ray image is limited by the number of quanta to the detector for the detection of 10 mm lung nodules when a radiation dose corresponding to a system with speed class 200 (leading to a detector dose of approximately 9 muGy behind the parenchyma) is used.
  •  
49.
  • Håkansson, Markus, et al. (författare)
  • Nodule detection in digital chest radiography: summary of the RADIUS chest trial.
  • 2005
  • Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 114:1-3, s. 114-20
  • Tidskriftsartikel (refereegranskat)abstract
    • As a part of the Europe-wide research project 'Unification of physical and clinical requirements for medical X-ray imaging'-governed by the Radiological Imaging Unification Strategies (RADIUS) Group-a major image quality trial was conducted by members of the group. The RADIUS chest trial aimed at thoroughly examining various aspects of nodule detection in digital chest radiography, such as the effects of nodule location, system noise, anatomical noise, and anatomical background. The main findings of the RADIUS chest trial concerning the detection of a lung nodule with a size in the order of 10 mm can be summarised as: (1) the detectability of the nodule is largely dependent on its location in the chest, (2) the system noise has a minor impact on the detectability at the dose levels used today, (3) the disturbance of the anatomical noise is larger than that of the system noise but smaller than that of the anatomical background and (4) the anatomical background acts as noise to a large extent and is the major image component affecting the detectability of the nodule.
  •  
50.
  • Håkansson, Markus, et al. (författare)
  • ViewDEX 2.0: A Java-based DICOM-compatible software for observer performance studies
  • 2009
  • Ingår i: Progress in Biomedical Optics and Imaging - Proceedings of SPIE. - : SPIE. - 1605-7422. ; 7263
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • ViewDEX (Viewer for Digital Evaluation of X-ray images) is a Java-based DICOM-compatible software tool for observer performance studies that can be used to display medical images with simultaneous registration of the observer's response. The current release, ViewDEX 2.0, is a development of ViewDEX 1.0, which was released in 2007. Both versions are designed to run in a Java environment and do not require any special installation. For example, the program can be located on a memory stick or stand alone hard drive and be run from there. ViewDEX is managed and configured by editing property files, which are plain text files where users, tasks (questions, definitions, etc.) and functionality (WW/WL, PAN, ZOOM, etc.) are defined. ViewDEX reads most common DICOM image formats and the images can be stored in any location connected to the computer. ViewDEX 2.0 is designed so that the user in a simple way can alter if the questions presented to the observers are related to localization or not, enabling e.g. free-response ROC, standard ROC and visual grading studies, as well as combinations of these, to be conducted in a fast and efficient way. The software can also be used for bench marking and for educational purposes. The results from each observer are saved in a log file, which can be exported for further analysis. The software is freely available for non-commercial purposes.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 41-50 av 148
Typ av publikation
Typ av innehåll
refereegranskat (127)
övrigt vetenskapligt/konstnärligt (21)
Författare/redaktör
Månsson, Lars Gunnar ... (62)
Johnsson, Åse (Allan ... (36)
Svalkvist, Angelica (34)
Vikgren, Jenny, 1957 (30)
Håkansson, Markus (23)
visa fler...
Kheddache, Susanne, ... (21)
Tingberg, Anders (20)
Mattsson, Sören (16)
Sund, Patrik (15)
Söderman, Christina (13)
Flinck, Agneta, 1953 (13)
Ruschin, Mark (12)
Rossi-Norrlund, Raun ... (11)
Hansson, Jonny (11)
Molnar, David (10)
Boijsen, Marianne, 1 ... (10)
Ivarsson, Jonas, 197 ... (9)
Hemdal, Bengt (9)
Thilander-Klang, Ann ... (9)
Zachrisson, Sara (9)
Grahn, Anna (9)
Rystedt, Hans, 1951 (8)
Lundh, Charlotta, 19 ... (8)
Andersson, Ingvar (8)
Börjesson, Sara (8)
Asplund, Sara, 1976 (7)
Fisichella, Valeria ... (7)
Medin, Joakim (5)
Timberg, Pontus (5)
Bernhardt, Peter, 19 ... (5)
Börjesson, S (4)
Besjakov, Jack (4)
Almén, Anja, 1964 (4)
Robinson, J. (3)
Svensson, S (3)
Alm Carlsson, Gudrun ... (3)
Sandborg, Michael, 1 ... (3)
Hellström, Mikael, 1 ... (3)
Almén, Anja (3)
Sandblom, Viktor, 19 ... (3)
Mattsson, S. (3)
Svensson, Johanna (3)
Svahn, Tony (3)
Söderberg, Jonas (3)
Thompson, N. (3)
Cederblad, Åke, 1947 (3)
Ullman, Gustaf (3)
Svensson, Sune (3)
Starck, Sven-Åke (3)
visa färre...
Lärosäte
Göteborgs universitet (148)
Lunds universitet (23)
Linköpings universitet (7)
Uppsala universitet (4)
Jönköping University (3)
Örebro universitet (2)
visa fler...
Karolinska Institutet (2)
Chalmers tekniska högskola (1)
RISE (1)
visa färre...
Språk
Engelska (148)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (146)
Teknik (9)
Naturvetenskap (5)
Samhällsvetenskap (5)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy