SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Aharrouche M.) "

Sökning: WFRF:(Aharrouche M.)

  • Resultat 241-247 av 247
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
241.
  • Aad, G., et al. (författare)
  • The ATLAS Experiment at the CERN Large Hadron Collider
  • 2008
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 3:S08003
  • Forskningsöversikt (refereegranskat)abstract
    • The ATLAS detector as installed in its experimental cavern at point 1 at CERN is described in this paper. A brief overview of the expected performance of the detector when the Large Hadron Collider begins operation is also presented.
  •  
242.
  • Abreu, H., et al. (författare)
  • Performance of the electronic readout of the ATLAS liquid argon calorimeters
  • 2010
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 5
  • Tidskriftsartikel (refereegranskat)abstract
    • The ATLAS detector has been designed for operation at the Large Hadron Collider at CERN. ATLAS includes electromagnetic and hadronic liquid argon calorimeters, with almost 200,000 channels of data that must be sampled at the LHC bunch crossing frequency of 40 MHz. The calorimeter electronics calibration and readout are performed by custom electronics developed specifically for these purposes. This paper describes the system performance of the ATLAS liquid argon calibration and readout electronics, including noise, energy and time resolution, and long term stability, with data taken mainly from full-system calibration runs performed after installation of the system in the ATLASdetector hall at CERN.
  •  
243.
  • Aharrouche, M., et al. (författare)
  • Energy linearity and resolution of the ATLAS electromagnetic barrel calorimeter in an electron test-beam
  • 2006
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 568:2, s. 601-623
  • Tidskriftsartikel (refereegranskat)abstract
    • A module of the ATLAS electromagnetic barrel liquid argon calorimeter was exposed to the CERN electron test-beam at the H8 beam line upgraded for precision momentum measurement. The available energies of the electron beam ranged from 10 to 245 GeV. The electron beam impinged at one point corresponding to a pseudo-rapidity of eta = 0.687 and an azimuthal angle of phi = 0.28 in the ATLAS coordinate system. A detailed study of several effects biasing the electron energy measurement allowed an energy reconstruction procedure to be developed that ensures a good linearity and a good resolution. Use is made of detailed Monte Carlo simulations based on GEANT4 which describe the longitudinal and transverse shower profiles as well as the energy distributions. For electron energies between 15 and 180 GeV the deviation of the measured incident electron energy over the beam energy is within 0.1%. The systematic uncertainty of the measurement is about 0.1% at low energies and negligible at high energies. The energy resolution is found to be about 10%. root E for the sampling term and about 0.2% for the local constant term.
  •  
244.
  • Aharrouche, M., et al. (författare)
  • Time resolution of the ATLAS barrel liquid argon electromagnetic calorimeter
  • 2008
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 597:2-3, s. 178-188
  • Tidskriftsartikel (refereegranskat)abstract
    • The time reconstruction performance of the ATLAS electromagnetic calorimeter readout is studied. The contribution of the electronics to the time resolution is estimated to be about 20 ps, thus demonstrating the possibility of achieving a small constant term in the time resolution for particles. The resolution to electromagnetic showers produced by an electron beam is also measured. After correction for the effects due to the calorimeter geometry, a 100 ps constant term is found for a typical cell.
  •  
245.
  • Aharrouche, M., et al. (författare)
  • Measurement of the response of the ATLAS liquid argon barrel calorimeter to electrons at the 2004 combined test-beam
  • 2010
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 614:3, s. 400-432
  • Tidskriftsartikel (refereegranskat)abstract
    • During summer and fall 2004, the response of a full slice of the ATLAS barrel detector to different particles was studied in controlled beam. One module of the ATLAS liquid argon barrel calorimeter identical to the production modules and read out by the final front-end and back-end electronics was used for electromagnetic calorimetry. This paper presents and discusses the electron performance of the LAr barrel calorimeter, including linearity, uniformity, and resolution with different amounts of material upstream the calorimeter and energies ranging from 1 to 250 GeV.
  •  
246.
  • Aharrouche, M., et al. (författare)
  • Response uniformity of the ATLAS liquid argon electromagnetic calorimeter
  • 2007
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 582:2, s. 429-455
  • Tidskriftsartikel (refereegranskat)abstract
    • The construction of the ATLAS electromagnetic liquid argon calorimeter modules is completed and all the modules are assembled and inserted in the cryostats. During the production period four barrel and three endcap modules were exposed to test beams in order to assess their performance, ascertain the production quality and reproducibility, and to scrutinize the complete energy reconstruction chain from the readout and calibration electronics to the signal and energy reconstruction. It was also possible to check the full Monte Carlo simulation of the calorimeter. The analysis of the uniformity, resolution and extraction of constant term is presented. Typical non-uniformities of 5 parts per thousand and typical global constant terms of 6 parts per thousand are measured for the barrel and endcap modules.
  •  
247.
  • Aharrouche, M., et al. (författare)
  • Study of the response of ATLAS electromagnetic liquid argon calorimeters to muons
  • 2009
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 606:3, s. 419-431
  • Tidskriftsartikel (refereegranskat)abstract
    • The response of the ATLAS electromagnetic calorimeter to muons has been studied in this paper. Results on signal over noise ratio, assessment of the detector response uniformity, and position resolution are presented. The possibility to study fine details of the structure of the detector through its response to muons is illustrated on a specific example. Finally, the performance obtained on muons in test-beam is used to estimate the detector uniformity and time alignment precision that will be reachable after the commissioning of the ATLAS detector with cosmic rays.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 241-247 av 247

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy