SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Gunji T.) "

Sökning: WFRF:(Gunji T.)

  • Resultat 221-230 av 234
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
221.
  • Mizuno, T., et al. (författare)
  • A Monte Carlo method for calculating the energy response of plastic scintillators to polarized photons below 100 keV
  • 2009
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 600:3, s. 609-617
  • Tidskriftsartikel (refereegranskat)abstract
    • The energy response of plastic scintillators (Eljen Technology EJ-204) to polarized soft gamma-ray photons below 100 keV has been studied, primarily for the balloon-borne polarimeter, PoGOLite. The response calculation includes quenching effects due to low-energy recoil electrons and the position dependence of the light collection efficiency in a 20 cm long scintillator rod. The broadening of the pulse-height spectrum, presumably caused by light transportation processes inside the scintillator, as well as the generation and multiplication of photoelectrons in the photomultiplier tube, were studied experimentally and have also been taken into account. A Monte Carlo simulation based on the Geant4 toolkit was used to model photon interactions in the scintillators. When using the polarized Compton/Rayleigh scattering processes previously corrected by the authors, scintillator spectra and angular distributions of scattered polarized photons could clearly be reproduced, in agreement with the results obtained at a synchrotron beam test conducted at the KEK Photon Factory. Our simulation successfully reproduces the modulation factor, defined as the ratio of the amplitude to the mean of the distribution of the azimuthal scattering angles, within similar to 5% (relative). Although primarily developed for the PoGOLite mission, the method presented here is also relevant for other missions aiming to measure polarization from astronomical objects using plastic scintillator scatterers. 
  •  
222.
  • Pearce, Mark, et al. (författare)
  • PoGOLite : A balloon-borne soft gamma-ray polarimeter
  • 2007
  • Ingår i: Proceedings of the 30th International Cosmic Ray Conference, ICRC 2007. - : Universidad Nacional Autonoma de Mexico. ; , s. 479-482
  • Konferensbidrag (refereegranskat)abstract
    • Polarized gamma-rays are expected from a wide variety of sources including rotationpowered pulsars, accreting black holes and neutron stars, and jet-dominated active galaxies. Polarization measurements provide a powerful probe of the gamma-ray emission mechanism and the distribution of magnetic and radiation fields around the source. No measurements have been performed in the soft gamma-ray band where non-thermal processes are expected to produce high degrees of polarization. The PoGOLite experiment applies well-type phoswich detector technology to polarization measurements in the 25 - 80 keV energy range. The instrument uses Compton scattering and photoabsorption in an array of 217 phoswich detector cells made of plastic and BGO scintillators, and surrounded by active BGO shields. A prototype of the flight instrument has been tested with polarized gammarays and background generated with radioactive sources. The test results and computer simulations confirm that the instrument can detect 10% polarization of a 200 mCrab source in one 6 hour balloon observation. In flight, targets are constrained to within better than 5% of the field-of-view (~5 degrees squared) in order to maximize the effective detection area during observations. The pointing direction on the sky is determined by an attitude control system comprising star trackers, differential GPS receiver system, gyroscopes, accelerometers and magnetometers which provide correction signals to a reaction wheel and torque motor system. Additionally, the entire polarimeter assembly rotates around its viewing axis to minimize systematic bias during observations. Flights are foreseen to start in 2009- 2010 and will target northern sky sources including the Crab pulsar/nebula, Cygnus X-1, and Hercules X-1. These observations will provide valuable information about the pulsar emission mechanism, the geometry around the black hole, and photon transportation in the strongly magnetized neutron star surface, respectively. Future goals include a long duration balloon flight from the Esrange facility in Northern Sweden to Canada.
  •  
223.
  • Tanaka, T., et al. (författare)
  • Data acquisition system for the PoGOLite astronomical hard X-ray polarimeter
  • 2007
  • Ingår i: Nuclear Science Symposium Conference Record, 2007. - 9781424409228 ; , s. 445-449, s. 445-449
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • The PoGOLite is a new balloon-borne instrument to measure the polarization of hard X-rays/soft gamma-rays in the 25-80 keV energy range for the first time. In order to detect the polarization, PoGOLite measures the azimuthal angle asymmetry of Compton scattering and the subsequent photo-absorption in an array of detectors. This array consists of 217 well-type phoswich detector cells (PDCs) surrounded by a side anti-coincidence shield (SAS) composed of 54 segments of BGO crystals. At balloon altitude, the intensity of backgrounds due to cosmic-ray charged particles, atmospheric gamma-rays and neutrons is extremely high, typically a few hundred Hz per unit. Hence the data acquisition (DAQ) system of PoGOLite is required to handle more than 270 signals simultaneously, and detect weak signals from astrophysical objects (100mCrab, 1.5 cs(-1) in 25-80 keV) under such a severe environment. We have developed a new DAQ system consisting of front-end electronics, waveform digitizer, Field Programmable Gate Array (FPGA) and a microprocessor. In this system, all output signals of PDC / SAS are fed into individual charge-sensitive amplifier and then digitized to 12 bit accuracy at 24 MSa/s by pipelined analog to digital converters. A DAQ board for the PDC records waveforms which will be examined in an off-line analysis to distinguish signals from the background events and measure the energy spectrum and polarization of targets. A board for the SAS records hit pattern to be used for background rejection. It also continuously records a pulse-height analysis (PHA) histogram to monitor incident background flux. These basic functions of the DAQ system were verified in a series of beam tests.
  •  
224.
  • Marinucci, A., et al. (författare)
  • Polarization constraints on the X-ray corona in Seyfert Galaxies : MCG-05-23-16
  • 2022
  • Ingår i: Monthly notices of the Royal Astronomical Society. - : Oxford University Press (OUP). - 0035-8711 .- 1365-2966. ; 516:4, s. 5907-5913
  • Tidskriftsartikel (refereegranskat)abstract
    • We report on the first observation of a radio-quiet active galactic nucleus (AGN) in polarized X-rays: the Seyfert 1.9 galaxy MCG-05-23-16. This source was pointed at with the Imaging X-ray Polarimetry Explorer (IXPE) starting on 2022 May 14 for a net observing time of 486 ks, simultaneously with XMM-Newton (58 ks) and NuSTAR (83 ks). A polarization degree Π smaller than 4.7 per cent (at the 99 per cent confidence level) is derived in the 2–8 keV energy range, where emission is dominated by the primary component ascribed to the hot corona. The broad-band spectrum, inferred from a simultaneous fit to the IXPE, NuSTAR, and XMM-Newton data, is well reproduced by a power law with photon index Γ = 1.85 ± 0.01 and a high-energy cutoff EC = 120 ± 15 keV. A comparison with Monte Carlo simulations shows that a lamp-post and a conical geometry of the corona are consistent with the observed upper limit, a slab geometry is allowed only if the inclination angle of the system is less than 50°.
  •  
225.
  • Mizuno, T., et al. (författare)
  • High sensitivity balloon-borne hard X-ray/soft Gamma-Ray Polarimeter PoGOLite
  • 2007
  • Ingår i: Nuclear Science Symposium Conference Record, 2007. NSS ’07. IEEE. - : IEEE. - 9781424409228 ; , s. 2538-2544
  • Konferensbidrag (refereegranskat)abstract
    • The Polarized Gamma-ray Observer - Lightweight version (PoGOLite) is a new balloon experiment capable of detecting 10% polarization from a 200 mCrab source in the 25-80 keV energy range in a single 6-hour flight for the first time. Polarization measurements of hard X-rays and soft gamma-rays are expected to provide a powerful probe into high-energy emission mechanisms as well as source geometries. PoGOLite uses Compton scattering and photo-absorption to measure polarization in an array of 217 well-type phoswich detector cells made of plastic and BGO scintillators. The adoption of a well-type phoswich counter concept and a thick polyethylene neutron shield provides a narrow field-of-view (1.25 msr), a large effective area ( gt; 250 cm2 at 40-50 keV), a high modulation factor (more than 25%) and the low background ( 100 mCrab) required to conduct high-sensitivity polarization measurements. Through tests in laboratories and accelerator facilities of a scaled-down prototype with the front-end electronics of flight design and an extensive study by Monte Carlo simulation, we have demonstrated high instrument performance. PoGOLite will be ready for a first engineering flight in 2009 and a science flight in 2010, during which polarization signals from the Crab Nebula/pulsar, Cygnus X-1 and other objects will be observed.
  •  
226.
  • Takahashi, H., et al. (författare)
  • A thermal-neutron detector with a phoswich system of LiCaAlF6 and BGO crystal scintillators onboard PoGOLite
  • 2010
  • Ingår i: 2010 IEEE Nuclear Science Symposium, Medical Imaging Conference, NSS/MIC 2010 and 17th International Workshop on Room-Temperature Semiconductor X-ray and Gamma-ray Detectors, RTSD 2010. ; , s. 32-37
  • Konferensbidrag (refereegranskat)abstract
    • To measure the flux of atmospheric neutrons and study the neutron contribution to the background of the main detector of the PoGOLite (Polarized Gamma-ray Observer) balloon-borne experiment, a thermal-neutron detector with a phoswich system of LiCaAlF6 (Eu) and BGO crystal scintillators is developed. The performance to separate thermal-neutron events from those of gamma-rays and charged particles is validated with 252Cf on ground. The detector is attached to the PoGOLite instrument and is launched in 2011 from the Esrange facility in the North of Sweden. Although the emission wavelength of the LiCaAlF6 (Ce) is 300 nm and overlaps with the absorption wavelength of the BGO, the phoswich capability of the LiCaAlF6 (Ce) with the BGO is also confirmed with installing a waveform shifter.
  •  
227.
  • Takahashi, H., et al. (författare)
  • Beam test results of the polarized gamma-ray observer, PoGOLite
  • 2008
  • Ingår i: 2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9. - 9781424427147 ; , s. 732-736
  • Konferensbidrag (refereegranskat)abstract
    • The Polarized Gamma-ray Observer, PoGOLite, is a balloon experiment with the capability of detecting 10% polarization from a 200 mCrab celestial object in the energy range 25 #x2013;80 keV. During a beam test at KEK-PF in February 2008, 20 detector units were assembled, and a 50 keV X-ray beam with a polarization degree of #x223C;90% was irradiated at the center unit. Signals from all 20 units were fed into flightversion electronics consisting of six circuit boards (four waveform digitizer boards, one digital I/O board and one router board) and one microprocessor (SpaceCube), which communicate using a SpaceWire interface. One digitizer board, which can associate up to 8 PDCs, outputs a trigger signal. The digital I/O board handles the trigger and returns a data acquisition request if there is no veto signal (upper or pulse-shape discriminators) from any detector unit. This data acquisition system worked well, and the modulation factor was successfully measured to be #x223C;34%. These results confirmed the capabilities of both detector and data-acquisition system for a pathfinder flight planned in 2010.
  •  
228.
  • Takahashi, H., et al. (författare)
  • The Polarized Gamma-Ray Observer, PoGOLite
  • 2010
  • Ingår i: Transactions of the Japanese Society for Artificial Intelligence, Aerospace Technology Japan. - 1346-0714 .- 1346-0714. ; 8
  • Tidskriftsartikel (refereegranskat)abstract
    • The Polarized Gamma-ray Observer, PoGOLite, is a balloon experiment with the capability of detecting 10% polarization from a 200 mCrab celestial object in the energy-range 25–80 keV. During a beam test at KEK-PF in 2008, 19 detector units and one anti-coincidence detector were assembled, and a 50 keV X-ray beam with a polarization degree of ∼90% was irradiated at the center unit. Signals from all 20 units were fed into flight-version electronics consisting of six circuit boards (four waveform digitizer boards, one digital I/O board and one router board) and one microprocessor (SpaceCube), which communicate using a SpaceWire interface. One digitizer board, which can associate up to 8 detectors, outputs a trigger signal. The digital I/O board handles the trigger and returns a data acquisition request if there is no veto signal (upper or pulse-shape discriminators) from any detector unit. This data acquisition system worked well, and the modulation factor was successfully measured to be ∼34%. These results confirmed the capabilities of the data-acquisition system for a “pathfinder” flight planned in 2010.
  •  
229.
  • Kiss, Mózsi, et al. (författare)
  • The PoGOLite balloon-borne soft gamma-ray polarimeter
  • 2008
  • Ingår i: COOL DISCS, HOT FLOWS. - : AIP. ; , s. 225-232
  • Konferensbidrag (refereegranskat)abstract
    • Linearly polarized radiation in the hard X-ray/soft gamma-ray band is expected from a large variety of astronomical sources. We discuss the importance of polarimetric studies for several classes of sources - pulsars, accreting black holes. magnetic neutron stars and jets from active galaxies - and then describe PoGOLite, a balloon-borne instrument which is currently under construction and will be able to measure the polarization of electromagnetic radiation from such extra-solar objects in the energy range 25-80 keV.
  •  
230.
  • Kurita, K., et al. (författare)
  • Recent Development Status of PoGOLite
  • 2009
  • Ingår i: Astrophysics with All-Sky X-Ray Observations. ; , s. 386-
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 221-230 av 234

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy