SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Markenroth Bloch Karin) "

Sökning: WFRF:(Markenroth Bloch Karin)

  • Resultat 21-30 av 50
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
21.
  • Hofman, Mark B.M., et al. (författare)
  • In-vivo validation of interpolation-based phase offset correction in cardiovascular magnetic resonance flow quantification : A multi-vendor, multi-center study
  • 2019
  • Ingår i: Journal of Cardiovascular Magnetic Resonance. - : Springer Science and Business Media LLC. - 1097-6647 .- 1532-429X. ; 21:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: A velocity offset error in phase contrast cardiovascular magnetic resonance (CMR) imaging is a known problem in clinical assessment of flow volumes in vessels around the heart. Earlier studies have shown that this offset error is clinically relevant over different systems, and cannot be removed by protocol optimization. Correction methods using phantom measurements are time consuming, and assume reproducibility of the offsets which is not the case for all systems. An alternative previously published solution is to correct the in-vivo data in post-processing, interpolating the velocity offset from stationary tissue within the field-of-view. This study aims to validate this interpolation-based offset correction in-vivo in a multi-vendor, multi-center setup. Methods: Data from six 1.5 T CMR systems were evaluated, with two systems from each of the three main vendors. At each system aortic and main pulmonary artery 2D flow studies were acquired during routine clinical or research examinations, with an additional phantom measurement using identical acquisition parameters. To verify the phantom acquisition, a region-of-interest (ROI) at stationary tissue in the thorax wall was placed and compared between in-vivo and phantom measurements. Interpolation-based offset correction was performed on the in-vivo data, after manually excluding regions of spatial wraparound. Correction performance of different spatial orders of interpolation planes was evaluated. Results: A total of 126 flow measurements in 82 subjects were included. At the thorax wall the agreement between in-vivo and phantom was - 0.2 ± 0.6 cm/s. Twenty-eight studies were excluded because of a difference at the thorax wall exceeding 0.6 cm/s from the phantom scan, leaving 98. Before correction, the offset at the vessel as assessed in the phantom was - 0.4 ± 1.5 cm/s, which resulted in a - 5 ± 16% error in cardiac output. The optimal order of the interpolation correction plane was 1st order, except for one system at which a 2nd order plane was required. Application of the interpolation-based correction revealed a remaining offset velocity of 0.1 ± 0.5 cm/s and 0 ± 5% error in cardiac output. Conclusions: This study shows that interpolation-based offset correction reduces the offset with comparable efficacy as phantom measurement phase offset correction, without the time penalty imposed by phantom scans. Trial registration: The study was registered in The Netherlands National Trial Register (NTR) under TC 4865. Registered 19 September 2014. Retrospectively registered.
  •  
22.
  • Kanski, Mikael, et al. (författare)
  • Whole-heart four-dimensional flow can be acquired with preserved quality without respiratory gating, facilitating clinical use : A head-to-head comparison
  • 2015
  • Ingår i: BMC Medical Imaging. - : Springer Science and Business Media LLC. - 1471-2342. ; 15:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Respiratory gating is often used in 4D-flow acquisition to reduce motion artifacts. However, gating increases scan time. The aim of this study was to investigate if respiratory gating can be excluded from 4D flow acquisitions without affecting quantitative intracardiac parameters. Methods: Eight volunteers underwent CMR at 1.5 T with a 5-channel coil (5ch). Imaging included 2D flow measurements and whole-heart 4D flow with and without respiratory gating (Resp(+), Resp(-)). Stroke volume (SV), particle-trace volumes, kinetic energy, and vortex-ring volume were obtained from 4D flow-data. These parameters were compared between 5ch Resp(+) and 5ch Resp(-). In addition, 20 patients with heart failure were scanned using a 32-channel coil (32ch), and particle-trace volumes were compared to planimetric SV. Paired comparisons were performed using Wilcoxon's test and correlation analysis using Pearson r. Agreement was assessed as bias ± SD. Results: Stroke volume from 4D flow was lower compared to 2D flow both with and without respiratory gating (5ch Resp(+) 88 ± 18 vs 97 ± 24.0, p = 0.001; 5ch Resp(-) 86 ± 16 vs 97.1 ± 22.7, p < 0.01). There was a good correlation between Resp(+) and Resp(-) for particle-trace derived volumes (R2 = 0.82, 0.2 ± 9.4 ml), mean kinetic energy (R2 = 0.86, 0.07 ± 0.21 mJ), peak kinetic energy (R2 = 0.88, 0.14 ± 0.77 mJ), and vortex-ring volume (R2 = 0.70, -2.5 ± 9.4 ml). Furthermore, good correlation was found between particle-trace volume and planimetric SV in patients for 32ch Resp(-) (R2 = 0.62, -4.2 ± 17.6 ml) and in healthy volunteers for 5ch Resp(+) (R2 = 0.89, -11 ± 7 ml), and 5ch Resp(-) (R2 = 0.93, -7.5 ± 5.4 ml), Average scan duration for Resp(-) was shorter compared to Resp(+) (27 ± 9 min vs 61 ± 19 min, p < 0.05). Conclusions: Whole-heart 4D flow can be acquired with preserved quantitative results without respiratory gating, facilitating clinical use.
  •  
23.
  • Knutsson, Linda, et al. (författare)
  • Absolute quantification of cerebral blood flow: correlation between dynamic susceptibility contrast MRI and model-free arterial spin labeling.
  • 2010
  • Ingår i: Magnetic Resonance Imaging. - : Elsevier BV. - 1873-5894 .- 0730-725X. ; 28:1, s. 1-7
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To compare absolute cerebral blood flow (CBF) estimates obtained by model-free arterial spin labeling (ASL) and dynamic susceptibility contrast MRI (DSC-MRI), corrected for partial volume effects (PVEs). METHODS: CBF was measured using DSC-MRI and model-free ASL (quantitative signal targeting with alternating radiofrequency labeling of arterial regions) at 3 T in 15 subjects with brain tumor, and the two modalities were compared with regard to CBF estimates in normal gray matter (GM) and DSC-to-ASL CBF ratios in selected tumor regions. The DSC-MRI CBF maps were calculated using a global arterial input function (AIF) from the sylvian-fissure region, but, in order to minimize PVEs, the AIF time integral was rescaled by a venous output function time integral obtained from the sagittal sinus. RESULTS: In GM, the average DSC-MRI CBF estimate was 150+/-45 ml/(min 100 g) (mean+/-SD) while the corresponding ASL CBF was 44+/-10 ml/(min 100 g). The linear correlation between GM CBF estimates obtained by DSC-MRI and ASL was r=.89, and observed DSC-to-ASL CBF ratios differed by less than 3% between GM and tumor regions. CONCLUSIONS: A satisfactory positive linear correlation between the CBF estimates obtained by model-free ASL and DSC-MRI was observed, and DSC-to-ASL CBF ratios showed no obvious tissue dependence.
  •  
24.
  • Knutsson, Linda, et al. (författare)
  • Arterial Input Functions and Tissue Response Curves in Dynamic Glucose-Enhanced (DGE) Imaging: Comparison Between glucoCEST and Blood Glucose Sampling in Humans
  • 2018
  • Ingår i: Tomography : a journal for imaging research. - : MDPI AG. - 2379-1381. ; 4:4, s. 164-171
  • Tidskriftsartikel (refereegranskat)abstract
    • Dynamic glucose-enhanced (DGE) imaging uses chemical exchange saturation transfer magnetic resonance imaging to retrieve information about the microcirculation using infusion of a natural sugar (D-glucose). However, this new approach is not yet well understood with respect to the dynamic tissue response. DGE time curves for arteries, normal brain tissue, and cerebrospinal fluid (CSF) were analyzed in healthy volunteers and compared with the time dependence of sampled venous plasma blood glucose levels. The arterial response curves (arterial input function [AIF]) compared reasonably well in shape with the time curves of the sampled glucose levels but could also differ substantially. The brain tissue response curves showed mainly negative responses with a peak intensity that was of the order of 10 times smaller than the AIF peak and a shape that was susceptible to both noise and partial volume effects with CSF, attributed to the low contrast-to-noise ratio. The CSF response curves showed a rather large and steady increase of the glucose uptake during the scan, due to the rapid uptake of D-glucose in CSF. Importantly, and contrary to gadolinium studies, the curves differed substantially among volunteers, which was interpreted to be caused by variations in insulin response. In conclusion, while AIFs and tissue response curves can be measured in DGE experiments,partial volume effects, low concentration of D-glucose in tissue, and osmolality effects between tissue and blood may prohibit quantification of normal tissue perfusion parameters. However, separation of tumor responses from normal tissue responses would most likely be feasible.
  •  
25.
  • Knutsson, Linda, et al. (författare)
  • Dynamic susceptibility contrast MRI with a prebolus contrast agent administration design for improved absolute quantification of perfusion.
  • 2014
  • Ingår i: Magnetic Resonance in Medicine. - : Wiley. - 1522-2594 .- 0740-3194. ; 72:4, s. 996-1006
  • Tidskriftsartikel (refereegranskat)abstract
    • Arterial partial-volume effects (PVEs) often hamper reproducible absolute quantification of cerebral blood flow (CBF) and cerebral blood volume (CBV) obtained by dynamic susceptibility contrast MRI (DSC-MRI). The aim of this study was to examine whether arterial PVEs in DSC-MRI data can be minimized by rescaling the arterial input function (AIF) using a sagittal-sinus venous output function obtained following a prebolus administration of a low dose of contrast agent.
  •  
26.
  •  
27.
  • Kylkilahti, Tekla Maria, et al. (författare)
  • Achieving brain clearance and preventing neurodegenerative diseases—A glymphatic perspective
  • 2021
  • Ingår i: Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism. - 0271-678X. ; 41:9, s. 2137-2149
  • Tidskriftsartikel (refereegranskat)abstract
    • Age-related neurodegenerative diseases are a growing burden to society, and many are sporadic, meaning that the environment, diet and lifestyle play significant roles. Cerebrospinal fluid (CSF)-mediated clearing of brain waste products via perivascular pathways, named the glymphatic system, is receiving increasing interest, as it offers unexplored perspectives on understanding neurodegenerative diseases. The glymphatic system is involved in clearance of metabolic by-products such as amyloid-β from the brain, and its function is believed to lower the risk of developing some of the most common neurodegenerative diseases. Here, we present magnetic resonance imaging (MRI) data on the heart cycle’s control of CSF flow in humans which corroborates findings from animal studies. We also review the importance of sleep, diet, vascular health for glymphatic clearance and find that these factors are also known players in brain longevity.
  •  
28.
  •  
29.
  • Markenroth Bloch, Karin, et al. (författare)
  • Benefits, Challenges and Applications of Ultra-High Field Magnetic Resonance
  • 2021. - 1
  • Ingår i: Advanced Neuro MR Techniques and Applications. - 9780128224793 - 9780128224953 ; 4, s. 533-571
  • Bokkapitel (refereegranskat)abstract
    • Human ultra-high field (UHF) MR at 7T and above has been on a rapid rise since the first installations in the 1990s, motivated by the opportunities created by SNR gains and contrast changes. Research efforts were for long focused mainly on technological developments to cope with the challenges posed by UHF. This has brought 7T MR neuroimaging to maturity and into an application dominated realm, further accelerated by the availability of clinically certified commercial 7T systems. This chapter aims to give an overview of UHF MR in a neuroimaging context by first providing an overview of the basic physical motivations for going to higher fields. It will then describe the challenges and limitations of working at higher field strengths, and outline some of the currently available solutions. This chapter also provides a discussion of the potentials of UHF by highlighting some of the neuro applications that benefit from UHF.
  •  
30.
  • Markenroth Bloch, Karin, et al. (författare)
  • Doppler ultrasound cardiac gating of intracranial flow at 7T
  • 2020
  • Ingår i: BMC Medical Imaging. - : Springer Science and Business Media LLC. - 1471-2342. ; 20:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Ultra-high field magnetic resonance imaging (MR) may be used to improve intracranial blood flow measurements. However, standard cardiac synchronization methods tend to fail at ultra-high field MR. Therefore, this study aims to investigate an alternative synchronization technique using Doppler ultrasound. Methods: Healthy subjects (n = 9) were examined with 7T MR. Flow was measured in the M1-branch of the middle cerebral artery (MCA) and in the cerebral aqueduct (CA) using through-plane phase contrast (2D flow). Flow in the circle of Willis was measured with three-dimensional, three-directional phase contrast (4D flow). Scans were gated with Doppler ultrasound (DUS) and electrocardiogram (ECG), and pulse oximetry data (POX) was collected simultaneously. False negative and false positive trigger events were counted for ECG, DUS and POX, and quantitative flow measures were compared. Results: There were fewer false positive triggers for DUS compared to ECG (5.3 ± 11 vs. 25 ± 31, p = 0.031), while no other measured parameters differed significantly. Net blood flow in M1 was similar between DUS and ECG for 2D flow (1.5 ± 0.39 vs. 1.6 ± 0.41, bias ± 1.96SD: − 0.021 ± 0.36) and 4D flow (1.8 ± 0.48 vs. 9 ± 0.59, bias ± 1.96SD: − 0.086 ± 0.57 ml). Net CSF flow per heart beat in the CA was also similar for DUS and ECG (3.6 ± 2.1 vs. 3.0 ± 5.8, bias ± 1.96SD: 0.61 ± 13.6 μl). Conclusion: Gating with DUS produced fewer false trigger events than using ECG, with similar quantitative flow values. DUS gating is a promising technique for cardiac synchronization at 7T.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 21-30 av 50
Typ av publikation
tidskriftsartikel (41)
bokkapitel (5)
konferensbidrag (3)
samlingsverk (redaktörskap) (1)
Typ av innehåll
refereegranskat (47)
övrigt vetenskapligt/konstnärligt (2)
populärvet., debatt m.m. (1)
Författare/redaktör
Markenroth Bloch, Ka ... (46)
Ståhlberg, Freddy (15)
Arheden, Håkan (10)
Töger, Johannes (10)
Carlsson, Marcus (8)
Wirestam, Ronnie (8)
visa fler...
Knutsson, Linda (8)
Björkman-Burtscher, ... (7)
Heiberg, Einar (7)
van Westen, Danielle (6)
Bloch, Karin Markenr ... (4)
Jonson, Björn (3)
Nilsson, Anders (3)
Sundgren, Pia C. (3)
Nilsson, Markus (3)
Ahlgren, André (3)
Lind, Emelie (3)
Kanski, Mikael (3)
Wasselius, Johan (3)
Andersen, Mads (3)
Kilner, Philip J (3)
Bergvall, Erik (3)
Olsrud, Johan (3)
van Osch, Matthias J ... (3)
Svensson, Jonas (2)
Helms, Gunther (2)
Siemund, Roger (2)
Borge, M. J. G. (2)
Mukha, I. (2)
Axelsson, L. (2)
Sorlin, O. (2)
Björkman-Burtscher, ... (2)
Hedström, Erik (2)
Lewitowicz, M. (2)
Steding-Ehrenborg, K ... (2)
Lätt, Jimmy (2)
Grevy, S. (2)
Orr, N. A. (2)
Saint-Laurent, M. G. (2)
Martel, I.I. (2)
Bergmann, U. C. (2)
Lundgaard, Iben (2)
Sparr, Gunnar (2)
Owman, Titti (2)
Van Zijl, Peter C M (2)
van Rossum, Albert C ... (2)
Xu, Xiang (2)
Gatehouse, Peter D. (2)
Rolf, Marijn P. (2)
Graves, Martin J. (2)
visa färre...
Lärosäte
Lunds universitet (49)
Göteborgs universitet (6)
Umeå universitet (1)
Luleå tekniska universitet (1)
Linköpings universitet (1)
Chalmers tekniska högskola (1)
Språk
Engelska (49)
Svenska (1)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (48)
Naturvetenskap (7)
Teknik (5)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy