SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Rubertsson Sten) "

Sökning: WFRF:(Rubertsson Sten)

  • Resultat 21-30 av 190
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
21.
  • Dankiewicz, Josef, et al. (författare)
  • Safety, Feasibility, and Outcomes of Induced Hypothermia Therapy Following In-Hospital Cardiac Arrest-Evaluation of a Large Prospective Registry
  • 2014
  • Ingår i: Critical Care Medicine. - 0090-3493 .- 1530-0293. ; 42:12, s. 2537-2545
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: Despite a lack of randomized trials, practice guidelines recommend that mild induced hypothermia be considered for comatose survivors of in-hospital cardiac arrest. This study describes the safety, feasibility, and outcomes of mild induced hypothermia treatment following in-hospital cardiac arrest. Design: Prospective, observational, registry-based study. Setting: Forty-six critical care facilities in eight countries in Europe and the United States reporting in the Hypothermia Network Registry and the International Cardiac Arrest Registry. Patients: A total of 663 patients with in-hospital cardiac arrest and treated with mild induced hypothermia were included between January 2004 and February 2012. Interventions: None. Measurements and Main Results: A cerebral performance category of 1 or 2 was considered a good outcome. At hospital discharge 41% of patients had a good outcome. At median 6-month follow-up, 34% had a good outcome. Among in-hospital deaths, 52% were of cardiac causes and 44% of cerebral cause. A higher initial body temperature was associated with reduced odds of a good outcome (odds ratio, 0.79; 95% CI, 0.68-0.92). Adverse events were common; bleeding requiring transfusion (odds ratio, 0.56; 95% CI, 0.31-1.00) and sepsis (odds ratio, 0.52; 95% CI, 0.30-0.91) were associated with reduced odds for a good outcome. Conclusions: In this registry study of an in-hospital cardiac arrest population treated with mild induced hypothermia, we found a 41% good outcome at hospital discharge and 34% at follow-up. Infectious complications occurred in 43% of cases, and 11% of patients required a transfusion for bleeding. The majority of deaths were of cardiac origin.
  •  
22.
  • Eiriksson, Kristinn, 1967-, et al. (författare)
  • Faster and safer resection with a stapler device: randomised, controlled trial of laparoscopic liver resection in a porcine model
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • Introduction. Many surgeons use stapling during liver resection. The stapler has the potential to close all luminal structures in the liver tissue and thus result in minimal bleeding, reduced danger of gas embolism, and a faster surgery. Material. Sixteen piglets where randomised into two groups receiving either laparoscopic liver resection with a vessel sealing system and an ultrasonic dissector (group-L) or with stapling (group-S). Pneumoperitoneum at 16 mmHg pressure was used. Gas embolism was detected with transesophageal ultrasound and intra-operative bleeding estimated. Monitoring of gas exchange with continuous recording of PaCO2, PaO2, end-tidal CO2, and pH was used. Invasive monitoring of systemic and pulmonary circulation was performed. Results. Stapling resulted in less bleeding (P = 0.026), less gas embolism (P = 0.001), and a shorter operating time (P = 0.004). Conclusion. In this animal model, stapling of the liver parenchyma led to a faster and safer resection compared to the use of a vessel sealing system and an ultrasonic dissector.
  •  
23.
  • Eiriksson, K., et al. (författare)
  • High intra-abdominal pressure during experimental laparoscopic liver resection reduces bleeding but increases the risk of gas embolism
  • 2011
  • Ingår i: British Journal of Surgery. - : Oxford University Press (OUP). - 0007-1323 .- 1365-2168. ; 98:6, s. 845-852
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Various recommendations exist regarding intra-abdominal pressure (IAP) during laparoscopic liver resection. A high IAP may reduce bleeding but at the same time increase the risk of gas embolism. This study investigated the effects of two different IAPs during laparoscopic left liver lobe resection in piglets. Methods: Sixteen piglets underwent laparoscopic left liver lobe resection using carbon dioxide pneumoperitoneum of either 8 or 16 mmHg (8 per group). A combination of CUSA System 200 (TM) and LigaSure (TM) instruments was used for parenchymal division. During resection, a standard injury to the left liver vein was also created to increase the risk of bleeding and/or gas embolism during the operation. Heart rate, cardiac output, and arterial, pulmonary arterial, pulmonary capillary wedge and central venous pressures were measured. Arterial blood gases were monitored continuously. Transoesophageal echocardiography was video recorded to detect and quantify gas embolism within the right cardiac ventricle. The duration of operation and bleeding were noted. Results: High IAP resulted in reduced bleeding (P = 0.016), but gas embolism occurred more frequently (P = 0.001) than with low IAP. Gas embolism disturbed gas exchange, with an increase in arterial pressure of carbon dioxide, and a decrease in arterial partial pressure of oxygen and pH. These effects were sustained for at least 30 min after surgery. Conclusion: High IAP reduces the amount of bleeding but increases the risk of gas embolism. Monitoring for gas embolism is therefore indicated if a high IAP is used during laparoscopic liver resection.
  •  
24.
  • Eiriksson, Kristinn, 1967-, et al. (författare)
  • Is there a difference between carbon dioxide and argon gas embolisms in laparoscopic liver resection?
  • Annan publikation (övrigt vetenskapligt/konstnärligt)abstract
    • Background:Several methods are available to control bleeding during laparoscopic liver resection (LLR).  One of these techniques, argon enhanced coagulation (AEC), could be hazardous because of the argon gas.  Argon gas has poorer solubility in blood than CO2.  Previous animal studies have shown the danger of gas embolism during LLR.  The aim of this study was to compare the effects of Argon gas embolism and CO2 embolism, with special emphasis on pulmonary circulation and gas exchange, during laparoscopic liver surgery.Method:Sixteen piglets underwent laparoscopic left lateral liver resection and were randomised to either CO2 or argon pneumoperitoneum, at 16 mmHg.  The pulmonary circulation of the animals was monitored with a pulmonary arterial catheter.  Paratrend® was used to continuously measure PaCO2, PaO2, and pH, and transoesophageal ultrasound was used to detect embolisms on the right side of the heart.Results: Equal amount of embolism were seen in both groups.  The mean pulmonary arterial pressure (MPAP) increased in the Argon-group (P=0.050) as did the pulmonary vascular resistance (PVR) (P=0.015) compared with the CO2-group, correlating with the amount of embolism.  The gas exchange was then affected with an decrease in PaO2 and increase in PaCO2 , resulting  in acidosis.Conclusion:Argon gas embolism has more effects on pulmonary circulation and gas exchange than CO2.  If used, great care should be taken with argon gas and the patient should be carefully monitored during LLR.
  •  
25.
  • Eiriksson, Kristinn, et al. (författare)
  • Laparoscopic left lobe liver resection in a porcine model : a study of the efficacy and safety of different surgical techniques
  • 2009
  • Ingår i: Surgical Endoscopy. - : Springer Science and Business Media LLC. - 0930-2794 .- 1432-2218. ; 23:5, s. 1038-1042
  • Tidskriftsartikel (refereegranskat)abstract
    • INTRODUCTION: Laparoscopic liver surgery is evolving and the best technique for dividing the liver parenchyma is currently under debate. The aim of this study was to study different techniques during a full laparoscopic lobe resection, and determine the efficacy and risks of bleeding and gas embolism. METHODS: Sixteen pigs were randomized to two groups: group US underwent an operation with Ultracision shears (AutoSonix) and ultrasonic dissector (CUSA) and group VS with a vessel sealing system (Ligasure) and ultrasonic dissector. A left lobe resection was performed. Transesophageal endoscopic echocardiography (TEE) was used to detect gas emboli in the right side of the heart and pulmonary artery. The operations and TEE were recorded for later assessment. RESULTS: Compared with group VS, group US exhibited significantly more intraoperative bleeding (p = 0.02), a trend towards a longer operation time (p = 0.08), and a trend towards more embolization for grade I emboli. In total, 10 of 15 animals had emboli during the operation. CONCLUSIONS: This study showed that a laparoscopic left lobe resection can be performed with a combination of AutoSonix and CUSA as well as with Ligasure and CUSA instrumentation. In our hands, less bleeding was incurred with Ligasure than with AutoSonix.
  •  
26.
  • Eiriksson, Kristinn, 1967- (författare)
  • Technical Aspects of Laparoscopic Liver Resection. An Experimental Study
  • 2012
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Various techniques are used to transect the liver. With increase in laparoscopic liver resections (LLR), it is of even more interest to develop surgical techniques to minimize bleeding and the risk for gas embolism during transection. Instrument like argon enhanced coagulator provides good hemostasis but increases the danger of gas embolism. The CO2 pneumoperitoneum that is routinely used in most types of laparoscopic surgery can be modified by the use of different gas pressure. It can be assumed that different pressure influences bleeding but also the risk for gas embolism.In presented porcine studies, three instrumental combinations have been studied. In study I sixteen piglets were randomized to LLR with either the cavitron ultrasonic aspirator (CUSA™) in combination with vessels sealing system (Ligasure™) or with CUSA™ and ultrascision scissors (Autosonix™), with the endpoints of intra-operative bleeding and gas embolism.  In study IV sixteen piglets were randomized to LLR either with staple device (Endo-GIA™) or the Ligasure™ - CUSA™ combination with same primary endpoints and additionally secondary endpoints of effect on gas-exchange, systemic- and pulmonary hemodynamic.Focusing on intra-abdominal pressure (IAP) in study II, sixteen piglets were randomized to LLR with an IAP of either 8 or 16 mmHg.  Primary endpoints were bleeding and gas embolism and secondary endpoints, effect on gas-exchange, systemic- and pulmonary hemodynamic.In study III effect of argon gas was tested during LLR. Sixteen piglets were randomized to either argon pneumoperitoneum or CO2 pneumoperitoneum. Primary endpoints were effect on gas-exchange, systemic- and pulmonary hemodynamic.In presented studies, we tested efficacy and safety of different techniques for LLR. CUSA™ can be used in combination with either Ligasure™ or Autosonix™. However, Ligasure™ reduces the amount of bleeding. The recent introduction of staplers seems promising with a further reduction in bleeding, gas embolism, and operating time. The IAP influences both the amount of bleeding as well as gas embolism. It seems reasonable to use a higher IAP to decrease bleeding with caution and with close monitoring for gas embolism. Argon gas embolism gives more extensive effect on gas-exchange and hemodynamic and should probably be avoided in this type of surgery.
  •  
27.
  • Ekbom, Emil, et al. (författare)
  • Impaired diffusing capacity for carbon monoxide is common in critically ill Covid-19 patients at four months post-discharge
  • 2021
  • Ingår i: Respiratory Medicine. - : Elsevier. - 0954-6111 .- 1532-3064. ; 182
  • Tidskriftsartikel (refereegranskat)abstract
    • There is limited knowledge about the long-term effects on pulmonary function of COVID-19 in patients that required intensive care treatment. Spirometry and diffusing capacity for carbon monoxide (DLCO) were measured in 60 subjects at 3-6 months post discharge. Impaired lung function was found in 52% of the subjects, with reduced DLCO as the main finding. The risk increased with age above 60 years, need for mechanical ventilation and longer ICU stay as well as lower levels of C-reactive protein at admission. This suggests the need of follow-up with pulmonary function testing in intensive-care treated patients.
  •  
28.
  • Elfwén, Ludvig, et al. (författare)
  • Coronary angiography in out-of-hospital cardiac arrest without ST elevation on ECG-Short- and long-term survival.
  • 2018
  • Ingår i: American Heart Journal. - : Elsevier BV. - 0002-8703 .- 1097-6744. ; 200, s. 90-95
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: The potential benefit of early coronary angiography in out-of-hospital cardiac arrest (OHCA) patients without ST elevation on ECG is unclear. The aim of this study was to evaluate the association between early coronary angiography and survival in these patients.METHODS: Nationwide observational study between 2008 and 2013. Included were patients admitted to hospital after witnessed OHCA, with shockable rhythm, age 18 to 80 years and unconscious. Patients with ST-elevation on ECG were excluded. Patients that underwent early CAG (within 24 hours) were compared with no early CAG (later during the hospital stay or not at all). Outcomes were survival at 30 days, 1 year, and 3 years. Multivariate analysis included pre-hospital factors, comorbidity and ECG-findings.RESULTS: In total, 799 OHCA patients fulfilled the inclusion criteria, of which 275 (34%) received early CAG versus 524 (66%) with no early CAG. In the early CAG group, the proportion of patients with an occluded coronary artery was 27% and 70% had at least one significant coronary stenosis (defined as narrowing of coronary lumen diameter of ≥50%). The 30-day survival rate was 65% in early CAG group versus 52% with no early CAG (P < .001). The adjusted OR was 1.42 (95% CI 1.00-2.02). The one-year survival rate was 62% in the early CAG group versus 48% in the no early CAG group with the adjusted hazard ratio of 1.35 (95% CI 1.04-1.77).CONCLUSION: In this population of bystander-witnessed cases of out-of-hospital cardiac arrest with shockable rhythm and ECG without ST elevation, early coronary angiography may be associated with improved short and long term survival.
  •  
29.
  • Elfwen, Ludvig, et al. (författare)
  • Direct or subacute coronary angiography in out-of-hospital cardiac arrest (DISCO)-An initial pilot-study of a randomized clinical trial
  • 2019
  • Ingår i: Resuscitation. - : ELSEVIER IRELAND LTD. - 0300-9572 .- 1873-1570. ; 139, s. 253-261
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: The clinical importance of immediate coronary angiography, with potentially subsequent percutaneous coronary intervention (PCI), in out-of-hospital cardiac arrest (OHCA) patients without ST-elevation on the ECG is unclear. In this study, we assessed feasibility and safety aspects of performing immediate coronary angiography in a pre-specified pilot phase of the 'DIrect or Subacute Coronary angiography in Out-of-hospital cardiac arrest' (DISCO) randomized controlled trial (ClinicalTrials.gov ID: NCT02309151). Methods: Resuscitated bystander witnessed OHCA patients > 18 years without ST-elevation on the ECG were randomized to immediate coronary angiography versus standard of care. Event times, procedure related adverse events and safety variables within 7 days were recorded. Results: In total, 79 patients were randomized to immediate angiography (n = 39) or standard of care (n = 40). No major differences in baseline characteristics between the groups were found. There were no differences in the proportion of bleedings and renal failure. Three patients randomized to immediate angiography and six patients randomized to standard care died within 24 h. The median time from EMS arrival to coronary angiography was 135 min in the immediate angiography group. In patients randomized to immediate angiography a culprit lesion was found in 14/38 (36.8%) and PCI was performed in all these patients. In 6/40 (15%) patients randomized to standard of care, coronary angiography was performed before the stipulated 3 days. Conclusion: In this out-of-hospital cardiac arrest population without ST-elevation, randomization to a strategy to perform immediate coronary angiography was feasible although the time window of 120 min from EMS arrival at the scene of the arrest to start of coronary angiography was not achieved. No significant safety issues were reported.
  •  
30.
  • Elfwen, Ludvig, et al. (författare)
  • Post-resuscitation myocardial dysfunction in out-of-hospital cardiac arrest patients randomized to immediate coronary angiography versus standard of care
  • 2020
  • Ingår i: IJC Heart & Vasculature. - : ELSEVIER IRELAND LTD. - 2352-9067. ; 27
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Immediate coronary angiography with subsequent percutaneous coronary intervention (PCI) has the potential to reduce post-resuscitation myocardial dysfunction in out-of-hospital cardiac arrest (OHCA) patients. The aim of this study was to see if immediate coronary angiography, with potential PCI, in patients without ST-elevation on the ECG, influenced post-resuscitation myocardial function and cardiac biomarkers.Methods: A secondary analysis of the Direct or Subacute Coronary Angiography in Out-of-Hospital Cardiac Arrest (DISCO) trial (ClinicalTrials.gov ID: NCT02309151). Patients with bystander-witnessed OHCA, without ST-elevations on the ECG were randomly assigned to immediate coronary angiography within two hours of cardiac arrest (n = 38) versus standard-of-care with deferred angiography (n = 40). Outcome measures included left ventricle ejection fraction (LVEF) at 24 h, peak Troponin T levels, lactate clearance and NT-proBNP at 72 h.Results: In the immediate-angiography group, median LVEF at 24 h was 47% (Q1-Q3; 30-55) vs. 46% (Q1-Q3; 35-55) in the standard-of-care group. Peak Troponin-T levels during the first 24 h were 362 ng/L (Q1-Q3; 174-2020) in the immediate angiography group and 377 ng/L (Q1-Q3; 205-1078) in the standard-of-care group. NT-proBNP levels at 72 h were 931 ng/L (Q1-Q3; 396-2845) in the immediate-angiography group and 1913 ng/L (Q1-Q3; 489-3140) in the standard-of-care group.Conclusion: In this analysis of OHCA patients without ST-elevation on the ECG randomized to immediate coronary angiography or standard-of-care, no differences in post-resuscitation myocardial dysfunction parameters between the two groups were found. This finding was consistent also in patients randomized to immediate coronary angiography where PCI was performed compared to those where PCI was not performed.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 21-30 av 190
Typ av publikation
tidskriftsartikel (148)
doktorsavhandling (14)
forskningsöversikt (8)
annan publikation (6)
konferensbidrag (5)
bokkapitel (5)
visa fler...
recension (2)
bok (1)
licentiatavhandling (1)
visa färre...
Typ av innehåll
refereegranskat (156)
övrigt vetenskapligt/konstnärligt (32)
populärvet., debatt m.m. (2)
Författare/redaktör
Rubertsson, Sten (180)
Wiklund, Lars (26)
Friberg, Hans (21)
Wallin, Ewa (20)
Lipcsey, Miklós (15)
Lindgren, Erik (13)
visa fler...
Frithiof, Robert (12)
Nordberg, Per (12)
Gedeborg, Rolf (11)
Nozari, A. (11)
Fors, Diddi (11)
Larsson, Ing-Marie (11)
Mörtberg, Erik (11)
Hollenberg, Jacob (10)
Nielsen, Niklas (10)
Larsson, Ing-Marie, ... (9)
Hultström, Michael, ... (9)
Johansson, Jakob (9)
Arvidsson, Dag (9)
Covaciu, Lucian (9)
Larsson, Anders (8)
Cronberg, Tobias (8)
Basu, Samar (8)
Stammet, Pascal (8)
Kristofferzon, Marja ... (8)
Rubertsson, Sten, Pr ... (8)
Svensson, Leif (7)
Forsberg, Sune (7)
Jonsson, Martin (7)
Smekal, David, 1971- (7)
Riva, Gabriel (7)
Karlsten, Rolf (7)
Sunde, Kjetil (7)
Lagedal, Rickard (7)
Herlitz, Johan, 1949 (6)
Zetterberg, Henrik, ... (6)
Herlitz, Johan (6)
Ringh, Mattias (6)
Claesson, Andreas (6)
Lunderquist, Anders (6)
Östlund, Ollie (6)
Riker, Richard R. (6)
Seder, David B. (6)
Blennow, Kaj, 1958 (5)
Ahlström, Håkan (5)
James, Stefan, 1964- (5)
Sandler, Håkan (5)
Kern, Karl B. (5)
Weis, Jan (5)
Elfwén, Ludvig (5)
visa färre...
Lärosäte
Uppsala universitet (177)
Lunds universitet (26)
Karolinska Institutet (20)
Göteborgs universitet (11)
Högskolan i Gävle (10)
Högskolan i Borås (10)
visa fler...
Linköpings universitet (4)
Stockholms universitet (1)
Örebro universitet (1)
visa färre...
Språk
Engelska (175)
Svenska (15)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (108)
Naturvetenskap (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy