SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(STROMBERG L) "

Sökning: WFRF:(STROMBERG L)

  • Resultat 11-20 av 93
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
11.
  •  
12.
  •  
13.
  •  
14.
  •  
15.
  •  
16.
  •  
17.
  •  
18.
  •  
19.
  •  
20.
  • Stromberg, L., et al. (författare)
  • Heroin impurity profiling - A harmonization study for retrospective comparisons
  • 2000
  • Ingår i: Forensic Science International. - 0379-0738 .- 1872-6283. ; 114:2, s. 67-88
  • Tidskriftsartikel (refereegranskat)abstract
    • Three laboratories present a harmonised system for the retrospective comparison of south west Asian heroin. It consists of an improved gas chromatographic (GC) profiling method and a computerised data retrieval. The investigations of the GC were necessary with a view to improve the reproducibility of the system. The necessity of a strict quality control is emphasized. The peaks of the GC profile were investigated for abundance, intensity, GC behaviour (reproducibility) and correlations, 16 of them were selected for describing the heroin profile in the database. The results from intra-lab profile comparisons are reported. The reproducibility of the analysis was good and the variation between the samples was large, thus, allowing conclusions with a high degree of certainty. The criteria of similarity were defined. The system is successfully running in all three labs. In connection with inter-laboratory comparison, the aspects of method harmonisation and standardisation are discussed. It appeared that the GC method is a very subtle one, urging for a strict standardisation between the three labs. Despite a long cooperation between three well-equipped and experienced labs, a more or less serious loss of reproducibility was noticed in the inter-lab results in comparison with the intra-lab results. The loss could for the greater part be attributed to the (limits of the) GC technique, a number of compounds, necessary for making the discrimination between samples, showed difficult chromatographic behaviour, leading to insufficient inter-lab reproducibility. Using the actual variables, improvements in performance can hardly be expected in the near future. The loss of reproducibility implies that the number of false positive matches in a database search increases. This may strongly reduce the value of a relatively large, international database. The study shows that so far, the best option for international comparison is the analysis in a central laboratory. The idea of local determination at a large number of national labs and the use of a common database is not a realistic aim for this type of analysis. (C) 2000 Elsevier Science Ireland Ltd.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 11-20 av 93

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy