1821. |
|
|
1822. |
|
|
1823. |
|
|
1824. |
|
|
1825. |
|
|
1826. |
|
|
1827. |
|
|
1828. |
|
|
1829. |
- Mueller, T., et al.
(författare)
-
Characterization and intercomparison of aerosol absorption photometers : result of two intercomparison workshops
- 2011
-
Ingår i: Atmospheric Measurement Techniques. - : Copernicus GmbH. - 1867-1381 .- 1867-8548. ; 4:2, s. 245-268
-
Tidskriftsartikel (refereegranskat)abstract
- Absorption photometers for real time application have been available since the 1980s, but the use of filter-based instruments to derive information on aerosol properties (absorption coefficient and black carbon, BC) is still a matter of debate. Several workshops have been conducted to investigate the performance of individual instruments over the intervening years. Two workshops with large sets of aerosol absorption photometers were conducted in 2005 and 2007. The data from these instruments were corrected using existing methods before further analysis. The inter-comparison shows a large variation between the responses to absorbing aerosol particles for different types of instruments. The unit to unit variability between instruments can be up to 30% for Particle Soot Absorption Photometers (PSAPs) and Aethalometers. Multi Angle Absorption Photometers (MAAPs) showed a variability of less than 5%. Reasons for the high variability were identified to be variations in sample flow and spot size. It was observed that different flow rates influence system performance with respect to response to absorption and instrumental noise. Measurements with non absorbing particles showed that the current corrections of a cross sensitivity to particle scattering are not sufficient. Remaining cross sensitivities were found to be a function of the total particle load on the filter. The large variation between the response to absorbing aerosol particles for different types of instruments indicates that current correction functions for absorption photometers are not adequate.
|
|
1830. |
- Muller, D. C., et al.
(författare)
-
No association between circulating concentrations of vitamin D and risk of lung cancer : an analysis in 20 prospective studies in the Lung Cancer Cohort Consortium (LC3)
- 2018
-
Ingår i: Annals of Oncology. - : Oxford University Press. - 0923-7534 .- 1569-8041. ; 29:6, s. 1468-1475
-
Tidskriftsartikel (refereegranskat)abstract
- Background: There is observational evidence suggesting that high vitamin D concentrations may protect against lung cancer. To investigate this hypothesis in detail, we measured circulating vitamin D concentrations in prediagnostic blood from 20 cohorts participating in the Lung Cancer Cohort Consortium (LC3).Patients and methods: The study included 5313 lung cancer cases and 5313 controls. Blood samples for the cases were collected, on average, 5 years before lung cancer diagnosis. Controls were individually matched to the cases by cohort, sex, age, race/ethnicity, date of blood collection, and smoking status in five categories. Liquid chromatography coupled with tandem mass spectrometry was used to separately analyze 25-hydroxyvitamin D2 [25(OH)D2] and 25-hydroxyvitamin D3 [25(OH)D3] and their concentrations were combined to give an overall measure of 25(OH)D. We used conditional logistic regression to calculate odds ratios (ORs) and 95% confidence intervals (CIs) for 25(OH)D as both continuous and categorical variables.Results: Overall, no apparent association between 25(OH)D and risk of lung cancer was observed (multivariable adjusted OR for a doubling in concentration: 0.98, 95% CI: 0.91, 1.06). Similarly, we found no clear evidence of interaction by cohort, sex, age, smoking status, or histology.Conclusion: This study did not support an association between vitamin D concentrations and lung cancer risk.
|
|