21.
  • Candefjord, Stefan, et al. (författare)
  • Evaluating the use of a Raman fiberoptic probe in conjunction with a resonance sensor for measuring porcine tissue in vitro
  • 2009
  • Ingår i: IFMBE Proceedings of the World Congress on Medical Physics and Biomedical Engineering. - Heidelberg : Springer. ; , s. 414-417, s. 414-417
  • Konferensbidrag (refereegranskat)abstract
    • Prostate cancer is the most common form of cancer and is the third leading cause of cancer-related death in European men. There is a need for new methods that can accurately localize and diagnose prostate cancer. In this study a new approach is presented: a combination of resonance sensor technology and Raman spectroscopy. Both methods have shown promising results for prostate cancer detection in vitro. The aim of this study was to evaluate the combined information from measurements with a Raman fiberoptic probe and a resonance sensor system. Pork belly tissue was used as a model system. A three-dimensional translation table was equipped with an in-house developed software, allowing measurements to be performed at the same point using two separate instruments. The Raman data was analyzed using principal component analysis and hierarchical clustering analysis. The spectra were divided into 5 distinct groups. The mean stiffness of each group was calculated from the resonance sensor measurements. One of the groups differed significantly (p < 0.05) from the others. A regression analysis, with the stiffness parameter as response variable and the principal component scores of the Raman data as the predictor variables, explained 67% of the total variability. The use of a smaller resonance sensor tip would probably increase the degree of correlation. In conclusion, Raman spectroscopy provides additional discriminatory power to the resonance sensor.
  •  
22.
  • Eklund, Anders, et al. (författare)
  • Evaluation of applanation resonator sensors for intra-ocular pressure measurement : results from clinical and in vitro studies.
  • 2003
  • Ingår i: Medical and Biological Engineering and Computing. - 0140-0118 .- 1741-0444. ; 41:2, s. 190-197
  • Tidskriftsartikel (refereegranskat)abstract
    • Glaucoma is an eye disease that, in its most common form, is characterised by high intra-ocular pressure (IOP), reduced visual field and optic nerve damage. For diagnostic purposes and for follow-up after treatment, it is important to have simple and reliable methods for measuring IOP. Recently, an applanation resonator sensor (ARS) for measuring IOP was introduced and evaluated using an in vitro pig-eye model. In the present study, the first clinical evaluation of the same probe has been carried out, with experiments in vivo on human eyes. There was a low but significant correlation between IOP(ARS) and the IOP measured with a Goldmann applanation tonometer (r = 0.40, p = 0.001, n = 72). However, off-centre positioning of the sensor against the cornea caused a non-negligible source of error. The sensor probe was redesigned to have a spherical, instead of flat, contact surface against the eye and was evaluated in the in vitro model. The new probe showed reduced sensitivity to off-centre positioning, with a decrease in relative deviation from 89% to 11% (1 mm radius). For normalised data, linear regression between IOP(ARS) and direct IOP measurement in the vitreous chamber showed a correlation of r = 0.97 (p < 0.001, n = 108) and a standard deviation for the residuals of SD < or = 2.18 mm Hg (n = 108). It was concluded that a spherical contact surface should be preferred and that further development towards a clinical instrument should focus on probe design and signal analysis.
  •  
23.
  • Fan, Xuelong, et al. (författare)
  • Effects of sensor types and angular velocity computational methods in field measurements of occupational upper arm and trunk postures and movements
  • 2021
  • Ingår i: Sensors. - : MDPI AG. - 1424-8220. ; 21:16
  • Tidskriftsartikel (refereegranskat)abstract
    • Accelerometer-based inclinometers have dominated kinematic measurements in previous field studies, while the use of inertial measurement units that additionally include gyroscopes is rapidly increasing. Recent laboratory studies suggest that these two sensor types and the two commonly used angular velocity computational methods may produce substantially different results. The aim of this study was, therefore, to evaluate the effects of sensor types and angular velocity computational methods on the measures of work postures and movements in a real occupational setting. Half-workday recordings of arm and trunk postures, and movements from 38 warehouse workers were compared using two sensor types: accelerometers versus accelerometers with gyroscopes—and using two angular velocity computational methods, i.e., inclination velocity versus generalized velocity. The results showed an overall small difference (<2° and value independent) for posture percentiles between the two sensor types, but substantial differences in movement percentiles both between the sensor types and between the angular computational methods. For example, the group mean of the 50th percentiles were for accelerometers: 71°/s (generalized velocity) and 33°/s (inclination velocity)—and for accelerometers with gyroscopes: 31°/s (generalized velocity) and 16°/s (inclination velocity). The significant effects of sensor types and angular computational methods on angular velocity measures in field work are important in inter-study comparisons and in comparisons to recommended threshold limit values.
  •  
24.
  • Fernandez, Ignasi, 1984, et al. (författare)
  • Long-term performance of distributed optical fiber sensors embedded in reinforced concrete beams under sustained deflection and cyclic loading
  • 2021
  • Ingår i: Sensors. - : MDPI AG. - 1424-8220. ; 21:19
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper explores the performance of distributed optical fiber sensors based on Rayleigh backscattering for the monitoring of strains in reinforced concrete elements subjected to different types of long-term external loading. In particular, the reliability and accuracy of robust fiber optic cables with an inner steel tube and an external protective polymeric cladding were investigated through a series of laboratory experiments involving large-scale reinforced concrete beams subjected to either sustained deflection or cyclic loading for 96 days. The unmatched spatial resolution of the strain measurements provided by the sensors allows for a level of detail that leads to new insights in the understanding of the structural behavior of reinforced concrete specimens. Moreover, the accuracy and stability of the sensors enabled the monitoring of subtle strain variations, both in the short-term due to changes of the external load and in the long-term due to time-dependent effects such as creep. Moreover, a comparison with Digital Image Correlation measurements revealed that the strain measurements and the calculation of deflection and crack widths derived thereof remain accurate over time. Therefore, the study concluded that this type of fiber optic has great potential to be used in real long-term monitoring applications in reinforced concrete structures.
  •  
25.
  • Fhager, Andreas, 1976, et al. (författare)
  • 3D Simulations of Intracerebral Hemorrhage Detection Using Broadband Microwave Technology
  • 2019
  • Ingår i: Sensors. - : MDPI AG. - 1424-8220. ; 19:16
  • Tidskriftsartikel (refereegranskat)abstract
    • Early, preferably prehospital, detection of intracranial bleeding after trauma or stroke would dramatically improve the acute care of these large patient groups. In this paper, we use simulated microwave transmission data to investigate the performance of a machine learning classification algorithm based on subspace distances for the detection of intracranial bleeding. A computational model, consisting of realistic human head models of patients with bleeding, as well as healthy subjects, was inserted in an antenna array model. The Finite-Difference Time-Domain (FDTD) method was then used to generate simulated transmission coefficients between all possible combinations of antenna pairs. These transmission data were used both to train and evaluate the performance of the classification algorithm and to investigate its ability to distinguish patients with versus without intracranial bleeding. We studied how classification results were affected by the number of healthy subjects and patients used to train the algorithm, and in particular, we were interested in investigating how many samples were needed in the training dataset to obtain classification results better than chance. Our results indicated that at least 200 subjects, i.e., 100 each of the healthy subjects and bleeding patients, were needed to obtain classification results consistently better than chance (p < 0.05 using Student's t-test). The results also showed that classification results improved with the number of subjects in the training data. With a sample size that approached 1000 subjects, classifications results characterized as area under the receiver operating curve (AUC) approached 1.0, indicating very high sensitivity and specificity.
  •  
26.
  • Forcolin, Fabio, et al. (författare)
  • Comparison of outlier heartbeat identification and spectral transformation strategies for deriving heart rate variability indices for drivers at different stages of sleepiness
  • 2018
  • Ingår i: Traffic Injury Prevention. - : Taylor & Francis. - 1538-9588 .- 1538-957X. ; 19, s. S112-S119
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: Appropriate preprocessing for detecting and removing outlier heartbeats and spectral transformation is essential for deriving heart rate variability (HRV) indices from cardiac monitoring data with high accuracy. The objective of this study is to evaluate agreement between standard preprocessing methods for cardiac monitoring data used to detect outlier heartbeats and perform spectral transformation, in relation to estimating HRV indices for drivers at different stages of sleepiness.Methods: The study analyzed more than 3,500 5-min driving epochs from 76 drivers on a public motorway in Sweden. Electrocardiography (ECG) data were recorded in 3 studies designed to evaluate the physiological differences between awake and sleepy drivers. The Pan-Tompkins algorithm was used for peak detection of heartbeats from ECG data. Two standard methods were used for identifying outlier heartbeats: (1) percentage change (PC), where outliers were defined as interbeat interval deviating >30% from the mean of the 4 previous intervals, and (2) standard deviation (SD), where outliers were defined as interbeat interval deviating >4 SD from the mean interval duration in the current epoch. Three standard methods were used for spectral transformation, which is needed for deriving HRV indices in the frequency domain; these methods were (1) the Fourier transform; (2) an autoregressive model; and (3) the Lomb-Scargle periodogram. The preprocessing methods were compared quantitatively and by assessing agreement between estimations of 13 common HRV indices using Bland-Altman plots and paired Student's t-tests.Results: The PC method detected more than 4times as many outliers (0.28%) than SD (0.065%). Most HRV indices derived using different preprocessing methods exhibited significant systematic (P <.05) and substantial random variations.Conclusions: The standard preprocessing methods for HRV data for outlier heartbeat detection and spectral transformation show low levels of agreement. This finding implies that, prior to designing algorithms for detection of sleepy drivers based on HRV analysis, the impact of different preprocessing methods and combinations thereof on driver sleepiness assessment needs to be studied.
  •  
27.
  • Forsman, Mikael, Professor, et al. (författare)
  • Mind the gap – development of conversion models between accelerometer- and IMU-based measurements of arm and trunk postures and movements in warehouse work
  • 2022
  • Ingår i: Applied Ergonomics. - : Elsevier BV. - 0003-6870 .- 1872-9126. ; 105
  • Tidskriftsartikel (refereegranskat)abstract
    • Sensor type (accelerometers only versus inertial measurement units, IMUs) and angular velocity computational method (inclination versus generalized velocity) have been shown to affect the measurements of arm and trunk movements. This study developed models for conversions between accelerometer and IMU measurements of arm and trunk inclination and between accelerometer and IMU measurements of inclination and generalized (arm) velocities. Full-workday recordings from accelerometers and IMUs of arm and trunk postures and movements from 38 warehouse workers were used to develop 4 angular (posture) and 24 angular velocity (movement) conversion models for the distributions of the data. A power function with one coefficient and one exponent was used, and it correlated well (r2 > 0.999) in all cases to the average curves comparing one measurement with another. These conversion models facilitate the comparison and merging of measurements of arm and trunk movements collected using the two sensor types and the two computational methods.
  •  
28.
  • Fredén Jansson, Karl-Johan, 1988 (författare)
  • The Balanced Electromagnetic Separation Transducer for Bone Conduction Audiometry and Hearing Rehabilitation
  • 2017
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Hearing via air conduction (AC) and bone conduction (BC) are attributed to bethe natural ways of conducting sound to the cochlea. With AC hearing, air pressurevariations are transmitted to the cochlea via the ear canal, whereas with BChearing, sound vibrations are transmitted through the skull bone to the cochlea.Patients with a hearing loss in the cochlea or auditory nerve are commonly rehabilitatedwith conventional AC hearing aids in the ear canal, but also using cochlearimplants. If the pathway for AC sound to reach the cochlea is obstructed, patientscan often benet from bone conduction devices (BCDs). In order to determinethe type and degree of hearing loss, the BC hearing thresholds are measured usinga bone conduction vibrator, and then analyzed together with the AC hearingthresholds for the diagnosis and to suggest an appropriate rehabilitation alternative.The motor unit in conventional BCDs and bone vibrators are known togenerate high amount of distortion at low frequencies where the Balanced ElectromagneticSeparation Transducer (BEST) principle may oer a new era in BChearing rehabilitation and audiometry.This thesis combines two BC hearing related topics, where the rst topic is anevaluation of a new audiometric bone vibrator, Radioear B81, which is assumedto oer more accurate BC hearing threshold measurements. The second topic isrelated to a new type of active transcutaneous BCD, called the Bone ConductionImplant (BCI), which leaves the skin intact by using a wireless solution thatdoes not require a permanent skin penetration. Even though the applications aredierent, both devices use the BEST principle as motor unit in their design.The audiometric bone vibrator Radioear B81 was found to have an improvedperformance at low frequencies where it can produce higher output levels with lessharmonic distortion than the conventional Radioear B71. In a clinical study of therst six patients, the BCI was found as ecient as already commercially availableBCDs, and with the advantage of not needing a skin penetration. In a technicalevaluation of the BCI, it was shown to be a mechanically robust design and totolerate magnetic resonance imaging at 1.5 Tesla.
  •  
29.
  • Geng, Zeyang, 1991, et al. (författare)
  • Validity of solid-state Li + diffusion coefficient estimation by electrochemical approaches for lithium-ion batteries
  • 2022
  • Ingår i: Electrochimica Acta. - : Elsevier BV. - 0013-4686 .- 1873-3859. ; 404
  • Tidskriftsartikel (refereegranskat)abstract
    • The solid-state diffusion coefficient of the electrode active material is one of the key parameters in lithium-ion battery modelling. Conventionally, this diffusion coefficient is estimated through the galvanostatic intermittent titration technique (GITT). In this work, the validity of GITT and a faster alternative technique, intermittent current interruption (ICI), are investigated regarding their effectiveness through a black-box testing approach. A Doyle-Fuller-Newman model with parameters for a LiNi0.8Mn0.1Co0.1O2 electrode is used as a fairly faithful representation as a real battery system, and the GITT and ICI experiments are simulated to extract the diffusion coefficient. With the parameters used in this work, the results show that both the GITT and ICI methods can identify the solid-state diffusion coefficient very well compared to the value used as input into the simulation model. The ICI method allows more frequent measurement but the experiment time is 85% less than what takes to perform a GITT test. Different fitting approaches and fitting length affected the estimation accuracy, however not significantly. Moreover, a thinner electrode, a higher C-rate and a greater electrolyte diffusion coefficient will lead to an estimation of a higher solid-state diffusion coefficient, generally closer to the target value.
  •  
30.
  • Gil Berrocal, Carlos, 1986, et al. (författare)
  • Crack monitoring in reinforced concrete beams by distributed optical fiber sensors
  • 2021
  • Ingår i: Structure and Infrastructure Engineering. - : Informa UK Limited. - 1573-2479 .- 1744-8980. ; 17:1, s. 124-139
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper investigates the use of distributed optical fiber sensors (DOFS) based on Optical Frequency Domain Reflectometry of Rayleigh backscattering for Structural Health Monitoring purposes in civil engineering structures. More specifically, the results of a series of laboratory experiments aimed at assessing the suitability and accuracy of DOFS for crack monitoring in reinforced concrete members subjected to external loading are reported. The experiments consisted on three-point bending tests of concrete beams, where a polyamide-coated optical fiber sensor was bonded directly onto the surface of an unaltered reinforcement bar and protected by a layer of silicone. The strain measurements obtained by the DOFS system exhibited an accuracy equivalent to that provided by traditional electrical foil gauges. Moreover, the analysis of the high spatial resolution strain profiles provided by the DOFS enabled the effective detection of crack formation. Furthermore, the comparison of the reinforcement strain profiles with measurements from a digital image correlation system revealed that determining the location of cracks and tracking the evolution of the crack width over time were both feasible, with most errors being below +/- 3 cm and +/- 20 mu m, for the crack location and crack width, respectively.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 21-30 av 1225
Typ av publikation
tidskriftsartikel (624)
konferensbidrag (398)
doktorsavhandling (87)
forskningsöversikt (35)
bokkapitel (28)
licentiatavhandling (24)
visa fler...
rapport (12)
annan publikation (12)
samlingsverk (redaktörskap) (3)
patent (2)
konstnärligt arbete (1)
visa färre...
Typ av innehåll
refereegranskat (968)
övrigt vetenskapligt/konstnärligt (249)
populärvet., debatt m.m. (8)
Författare/redaktör
Persson, Mikael, 195 ... (46)
Lindecrantz, Kaj, 19 ... (40)
Seoane, Fernando, 19 ... (39)
Wårdell, Karin (38)
Fhager, Andreas, 197 ... (34)
Brodin, Lars-Åke (28)
visa fler...
Strömberg, Tomas (27)
Osvalder, Anna-Lisa, ... (22)
Laurell, Thomas (20)
Larsson, Marcus (20)
Fredriksson, Ingemar (19)
Seoane Martinez, Fer ... (19)
Jalkanen, Ville, 197 ... (19)
Bergh, Anders (17)
Augustine, Robin, 19 ... (17)
Grishenkov, Dmitry, ... (17)
Tenje, Maria (16)
Bligård, Lars-Ola, 1 ... (16)
Thordstein, Magnus (15)
Dobsicek Trefna, Han ... (15)
Knutsson, Hans (14)
Lindahl, Olof A. (14)
Ljungberg, Börje (13)
Ramser, Kerstin (13)
Theodorsson, Elvar (12)
Ask, Per (12)
Kjellmer, Ingemar, 1 ... (12)
Lindahl, Olof (12)
Cinthio, Magnus (11)
Paradossi, Gaio (11)
Danielsson, Mats (11)
Nilsson, Gert (11)
Cederström, Björn (11)
Borga, Magnus (10)
Lindecrantz, Kaj (10)
Janerot-Sjöberg, Bir ... (10)
Olsson, Torsten, 193 ... (10)
Candefjord, Stefan, ... (10)
Seoane, Fernando (9)
Torres Company, Vict ... (9)
Holzapfel, Gerhard A ... (9)
Ebbers, Tino (9)
Löfgren, Nils, 1969 (9)
Buendia, Ruben, 1982 (9)
Andersson-Engels, St ... (8)
Gil-Pita, Roberto (8)
Augustsson, Per (8)
Reinfeldt, Sabine, 1 ... (8)
Winter, Reidar (8)
Nowak, Jacek (8)
visa färre...
Lärosäte
Chalmers tekniska högskola (364)
Kungliga Tekniska Högskolan (278)
Linköpings universitet (255)
Lunds universitet (181)
Göteborgs universitet (96)
Uppsala universitet (87)
visa fler...
Umeå universitet (80)
Karolinska Institutet (77)
Högskolan i Borås (59)
Luleå tekniska universitet (22)
Blekinge Tekniska Högskola (18)
RISE (14)
Örebro universitet (13)
Linnéuniversitetet (13)
Mälardalens universitet (12)
Stockholms universitet (11)
Jönköping University (11)
Malmö universitet (9)
VTI - Statens väg- och transportforskningsinstitut (8)
Gymnastik- och idrottshögskolan (7)
Högskolan i Halmstad (6)
Sveriges Lantbruksuniversitet (6)
Mittuniversitetet (4)
Högskolan Kristianstad (3)
Högskolan i Gävle (1)
Högskolan Väst (1)
Högskolan i Skövde (1)
Karlstads universitet (1)
Högskolan Dalarna (1)
visa färre...
Språk
Engelska (1195)
Svenska (26)
Tyska (2)
Rumänska (1)
Kinesiska (1)
Forskningsämne (UKÄ/SCB)
Teknik (1225)
Medicin och hälsovetenskap (311)
Naturvetenskap (240)
Samhällsvetenskap (28)
Humaniora (9)
Lantbruksvetenskap (4)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy